3 research outputs found
Platelet and coagulation disorders in newly diagnosed patients with pulmonary arterial hypertension
<p>There is a complex and not fully elucidated association between pulmonary arterial hypertension (PAH) and coagulation disorders. The goal of this study was to evaluate platelet function, coagulation and fibrinolysis in PAH patients at diagnosis, before PAH-specific treatment initiation. We enrolled 20 healthy controls and 30 PAH patients (20 with connective tissue disease (CTD-PAH) and 10 idiopathic (iPAH)). None of the participants was on any antiplatelet or anticoagulation therapy. Blood samples from PAH patients were collected during the initial right heart catheterization. All subjects were assessed with platelet function analyzer-100 (PFA-100), epinephrine (Epi) and ADP-induced light transmission aggregometry (LTA), thromboelastometry (ROTEM) and endogenous thrombin potential (ETP). Our results showed that Epi and ADP-LTA values were significantly lower in newly diagnosed PAH patients compared to controls. Disaggregation was present in 73% of patients, a characteristic not seen in healthy individuals. In ROTEM assay, CT and CFT measurements were significantly higher and a angle lower compared to controls. ETP testing revealed significantly reduced outcomes in AUC, Cmax and Tmax. When CTD-PAH and iPAH patient groups were compared, iPAH ADP-LTA values were significantly decreased compared to CTD-PAH. In conclusion, newly diagnosed PAH patients presented with decreased platelet aggregation, clot propagation and thrombin generation, along with delayed initiation of the coagulation process. These hemostatic deficits could indicate an “exhaustion” of the coagulation process that could be caused by endothelial dysfunction and chronic activation of the procoagulant pathways. Further studies are warranted to confirm these laboratory findings and assess their potential clinical significance.</p
Table1_Development and validation of a sepsis diagnostic scoring model for neonates with suspected sepsis.docx
BackgroundWe aimed to develop and validate a diagnostic model for sepsis among neonates evaluated for suspected sepsis, by incorporating thromboelastometry parameters, maternal/neonatal risk factors, clinical signs/symptoms and laboratory results.MethodsThis retrospective cohort study included 291 neonates with presumed sepsis, hospitalized in a NICU, from 07/2014 to 07/2021. Laboratory tests were obtained on disease onset and prior to initiating antibiotic therapy. Τhromboelastometry extrinsically activated (EXTEM) assay was performed simultaneously and Tοllner and nSOFA scores were calculated. Sepsis diagnosis was the outcome variable. A 10-fold cross-validation least absolute shrinkage and selection operator logit regression procedure was applied to derive the final multivariable score. Clinical utility was evaluated by decision curve analysis.ResultsGestational age, CRP, considerable skin discoloration, liver enlargement, neutrophil left shift, and EXTEM A10, were identified as the strongest predictors and included in the Neonatal Sepsis Diagnostic (NeoSeD) model. NeoSeD score demonstrated excellent discrimination capacity for sepsis and septic shock with an AUC: 0.918 (95% CI, 0.884–0.952) and 0.974 (95% CI, 0.958–0.989) respectively, which was significantly higher compared to Töllner and nSOFA scores.ConclusionsThe NeoSeD score is simple, accurate, practical, and may contribute to a timely diagnosis of sepsis in neonates with suspected sepsis. External validation in multinational cohorts is necessary before clinical application.</p
DataSheet1_Development and validation of a sepsis diagnostic scoring model for neonates with suspected sepsis.docx
BackgroundWe aimed to develop and validate a diagnostic model for sepsis among neonates evaluated for suspected sepsis, by incorporating thromboelastometry parameters, maternal/neonatal risk factors, clinical signs/symptoms and laboratory results.MethodsThis retrospective cohort study included 291 neonates with presumed sepsis, hospitalized in a NICU, from 07/2014 to 07/2021. Laboratory tests were obtained on disease onset and prior to initiating antibiotic therapy. Τhromboelastometry extrinsically activated (EXTEM) assay was performed simultaneously and Tοllner and nSOFA scores were calculated. Sepsis diagnosis was the outcome variable. A 10-fold cross-validation least absolute shrinkage and selection operator logit regression procedure was applied to derive the final multivariable score. Clinical utility was evaluated by decision curve analysis.ResultsGestational age, CRP, considerable skin discoloration, liver enlargement, neutrophil left shift, and EXTEM A10, were identified as the strongest predictors and included in the Neonatal Sepsis Diagnostic (NeoSeD) model. NeoSeD score demonstrated excellent discrimination capacity for sepsis and septic shock with an AUC: 0.918 (95% CI, 0.884–0.952) and 0.974 (95% CI, 0.958–0.989) respectively, which was significantly higher compared to Töllner and nSOFA scores.ConclusionsThe NeoSeD score is simple, accurate, practical, and may contribute to a timely diagnosis of sepsis in neonates with suspected sepsis. External validation in multinational cohorts is necessary before clinical application.</p