178 research outputs found

    The Regional Sensitivity of Chondrocyte Gene Expression to Coactive Mechanical Load and Exogenous TNF-a Stimuli

    Get PDF
    Both mechanical load and elevated levels of proinflammatory cytokines have been associated with the risk for developing osteoarthritis (OA), yet the potential interaction of these mechanical and biological factors is not well understood. The purpose of this study was to evaluate the response of chondrocytes to the effects of dynamic unconfined compression, TNF-a, and the simultaneous effects of dynamic unconfined compression and TNF-a. The response to these three treatments was markedly different and, taken together, the response in the gene expression of chondrocytes to the different treatment conditions suggest a complex interaction between structure, biology, and mechanical loading

    Severe axial vertebral rotation treated with a modified Boston brace: a case report

    Get PDF
    We report the case of a 13-year-old Caucasian girl suffering from severe axial rotation of the T5 to L4 vertebrae. The patient (initially examined during a school screening study) was at first considered to be suspicious of suffering from scoliosis due to a highly positive Adam's forward bending test. However, her radiographic evaluation revealed the existence of axial rotation in 12 of her vertebrae, without inclination in the sagittal and coronal planes. After an observation period of 12 months and due to the fact that both her physical appearance and the measured vertebral rotation deteriorated, the patient was given a modified thoracolumbar Boston brace that had an immediate positive derotational effect on all but two vertebrae. Twenty four months later, the progress of the vertebral rotation(s) seems to have been halted and most affected vertebrae appear to be stabilized in their new, 'post-brace', reduced position, with better results shown when the Boston brace is worn. The patient remains under constant medical observation. The application of a modified Boston brace seems to have served well (so far) a useful purpose for reducing and stabilizing this case of severe axial vertebral rotation, providing less deformity and (possibly) offering a better final cosmetic result

    Development of a planar multi-body model of the human knee joint

    Get PDF
    The aim of this work is to develop a dynamic model for the biological human knee joint. The model is formulated in the framework of multibody systems methodologies, as a system of two bodies, the femur and the tibia. For the purpose of describing the formulation, the relative motion of the tibia with respect to the femur is considered. Due to their higher stiffness compared to that of the articular cartilages, the femur and tibia are considered as rigid bodies. The femur and tibia cartilages are considered to be deformable structures with specific material characteristics. The rotation and gliding motions of the tibia relative to the femur can not be modeled with any conventional kinematic joint, but rather in terms of the action of the knee ligaments and potential contact between the bones. Based on medical imaging techniques, the femur and tibia profiles in the sagittal plane are extracted and used to define the interface geometric conditions for contact. When a contact is detected, a continuous non-linear contact force law is applied which calculates the contact forces developed at the interface as a function of the relative indentation between the two bodies. The four basic cruciate and collateral ligaments present in the knee are also taken into account in the proposed knee joint model, which are modeled as non-linear elastic springs. The forces produced in the ligaments, together with the contact forces, are introduced into the system’s equations of motion as external forces. In addition, an external force is applied on the center of mass of the tibia, in order to actuate the system mimicking a normal gait motion. Finally, numerical results obtained from computational simulations are used to address the assumptions and procedures adopted in this study.Fundação para a Ciência e a Tecnologia (FCT

    A treatment applying a biomechanical device to the feet of patients with knee osteoarthritis results in reduced pain and improved function: a prospective controlled study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study examined the effect of treatment with a novel biomechanical device on the level of pain and function in patients with knee OA.</p> <p>Methods</p> <p>Patients with bilateral knee OA were enrolled to active and control groups. Patients were evaluated at baseline, at 4 weeks and at the 8-week endpoint. A novel biomechanical device was individually calibrated to patients from the active group. Patients from the control group received an identical foot-worn platform without the biomechanical elements. Primary outcomes were the WOMAC Index and ALF assessments.</p> <p>Results</p> <p>There were no baseline differences between the groups. At 8 weeks, the active group showed a mean improvement of 64.8% on the WOMAC pain scale, a mean improvement of 62.7% on the WOMAC function scale, and a mean improvement of 31.4% on the ALF scale. The control group demonstrated no improvement in the above parameters. Significant differences were found between the active and control groups in all the parameters of assessment.</p> <p>Conclusions</p> <p>The biomechanical device and treatment methodology is effective in significantly reducing pain and improving function in knee OA patients.</p> <p>The study is registered at clinicaltrials.gov, identifier NCT00457132, <url>http://www.clinicaltrials.gov/ct/show/NCT00457132?order=1</url></p

    Numerical Simulation of Asymmetrically Altered Growth as Initiation Mechanism of Scoliosis

    Get PDF
    The causes of idiopathic scoliosis are still uncertain; buckling is mentioned often, but never proven. The authors hypothesize another option: unilateral postponement of growth of MM Rotatores or of ligamentum flavum and intertransverse ligament. In this paper, both buckling and the two new theories of scoliotic initiation are studied using a new finite element model that simulates the mechanical behavior of the human spine. This model was validated by the stiffness data of Panjabi et al. (J. Biomech. 9:185–192, 1976). After a small correction of the prestrain of some ligaments and the MM Rotatores the model appeared to be valid. The postponement in growth was translated in the numerical model in an asymmetrical stiffness. The spine was loaded axially and the resulting deformation was analyzed for the presence of the coupling of lateral deviation and axial rotation that is characteristic for scoliosis. Only unilateral postponement of growth of ligamentum flavum and intertransverse ligament appeared to initiate scoliosis. Buckling did not initiate scoliosis

    Restoring tibiofemoral alignment during ACL reconstruction results in better knee biomechanics

    Get PDF
    "Published online: 24 October 2017"PURPOSE: Anterior cruciate ligament (ACL) reconstruction (ACLR) aims to restore normal knee joint function, stability and biomechanics and in the long term avoid joint degeneration. The purpose of this study is to present the anatomic single bundle (SB) ACLR that emphasizes intraoperative correction of tibiofemoral subluxation that occurs after ACL injury. It was hypothesized that this technique leads to optimal outcomes and better restoration of pathological tibiofemoral joint movement that results from ACL deficiency (ACLD). METHODS: Thirteen men with unilateral ACLD were prospectively evaluated before and at a mean follow-up of 14.9 (SD = 1.8) months after anatomic SB ACLR with bone patellar tendon bone autograft. The anatomic ACLR replicated the native ACL attachment site anatomy and graft orientation. Emphasis was placed on intraoperative correction of tibiofemoral subluxation by reducing anterior tibial translation (ATT) and internal tibial rotation. Function was measured with IKDC, Lysholm and the Tegner activity scale, ATT was measured with the KT-1000 arthrometer and tibial rotation (TR) kinematics were measured with 3Dmotion analysis during a high-demand pivoting task. RESULTS: The results showed significantly higher TR of the ACL-deficient knee when compared to the intact knee prior to surgery (12.2° ± 3.7° and 10.7° ± 2.6° respectively, P = 0.014). Postoperatively, the ACLR knee showed significantly lower TR as compared to the ACL-deficient knee (9.6°±3.1°, P = 0.001) but no difference as compared to the control knee (n.s.). All functional scores were significantly improved and ATT was restored within normal values (P < 0.001). CONCLUSIONS: Intraoperative correction of tibiofemoral subluxation that results after ACL injury is an important step during anatomic SB ACLR. The intraoperative correction of tibiofemoral subluxation along with the replication of native ACL anatomy results in restoration of rotational kinematics of ACLD patients to normal levels that are comparable to the control knee. These results indicate that the reestablishment of tibiofemoral alignment during ACLR may be an important step that facilitates normal knee kinematics postoperatively. LEVEL OF EVIDENCE: Level II, prospective cohort study.The authors gratefully acknowledge the funding support from the Hellenic Association of Orthopaedic Surgery and Traumatology (HAOST-EEXOT)info:eu-repo/semantics/publishedVersio

    Innovations in total knee replacement: new trends in operative treatment and changes in peri-operative management

    Get PDF
    The human knee joint can sustain damage due to injury, or more usually osteoarthritis, to one, two or all three of the knee compartments: the medial femorotibial, the lateral femorotibial and the patellofemoral compartments. When pain associated with this damage is unmanageable using nonsurgical techniques, knee replacement surgery might be the most appropriate course of action. This procedure aims to restore a pain-free, fully functional and durable knee joint. Total knee replacement is a well-established treatment modality, and more recently, partial knee replacement—more commonly known as bi- or unicompartmental knee replacement—has seen resurgence in interest and popularity. Combined with the use of minimally invasive surgery (MIS) techniques, gender-specific prosthetics and computer-assisted navigation systems, orthopaedic surgeons are now able to offer patients knee replacement procedures that are associated with (1) minimal risks during and after surgery by avoiding fat embolism, reducing blood loss and minimising soft tissue disruption; (2) smaller incisions; (3) faster and less painful rehabilitation; (4) reduced hospital stay and faster return to normal activities of daily living; (5) an improved range of motion; (6) less requirement for analgesics; and (7) a durable, well-aligned, highly functional knee. With the ongoing advancements in surgical technique, medical technology and prosthesis design, knee replacement surgery is constantly evolving. This review provides a personal account of the recent innovations that have been made, with a particular emphasis on the potential use of MIS techniques combined with computer-assisted navigation systems to treat younger, more physically active patients with resurfacing partial/total implant knee arthroplasty
    corecore