18 research outputs found

    Pandemic (H1N1) 2009 Cluster Analysis: A Preliminary Assessment

    Get PDF
    Pandemic (H1N1) 2009 virus has been causing major concerns around the world because of its epidemic potential, rapid dissemination, rate of mutations, and the number of fatalities. One way to gain an advantage over this virus is to use existing rapid bioinformatics tools to examine easily and inexpensively generated genetic sequencing data. We have used the protein sequences deposited with the National Center for Biotechnology Information (NCBI) for data mining to study the relationship among the Pandemic (H1N1) 2009 proteins. There are 11 proteins in the Pandemic (H1N1) 2009 virus, and analysis of sequences from 65 different locations around the globe has resulted in two major clusters. These clusters illustrate the Pandemic H1N1 2009 virus is already experiencing significant genetic drift and that rapid worldwide travel is affecting the distribution of genetically distinct isolates

    Survival of Viral Biowarfare Agents in Disinfected Waters

    Get PDF
    Protecting civilian and military water supplies has received more attention since the United States began its war on terror in 2001. Both chlorine and bromine are used by branches of the U.S. military for disinfecting water supplies; however, limited data exists as to the effectiveness of these additives when used against viral biowarfare agents. The present study sought to evaluate the survival of selected viral biothreat agents in disinfected water. Disinfected water samples were spiked with vaccinia virus strain WR and Venezuelan equine encephalitis (VEE) virus strain TC-83 each separately to a final concentration of approximately 1 × 106 PFU/mL, and survival was assessed by plaque assay. Both viruses were inactivated by 1 mg/L free available chlorine (FAC) and 2mg/L total bromine within one hour. In conclusion, these results demonstrate that both chlorine and bromine are effective disinfectants against vaccinia virus and VEE strain TC-83 at the concentrations tested

    Evaluation of Handheld Assays for the Detection of Ricin and Staphylococcal Enterotoxin B in Disinfected Waters

    Get PDF
    Development of a rapid field test is needed capable of determining if field supplies of water are safe to drink by the warfighter during a military operation. The present study sought to assess the effectiveness of handheld assays (HHAs) in detecting ricin and Staphylococcal Enterotoxin B (SEB) in water. Performance of HHAs was evaluated in formulated tap water with and without chlorine, reverse osmosis water (RO) with chlorine, and RO with bromine. Each matrix was prepared, spiked with ricin or SEB at multiple concentrations, and then loaded onto HHAs. HHAs were allowed to develop and then read visually. Limits of detection (LOD) were determined for all HHAs in each water type. Both ricin and SEB were detected by HHAs in formulated tap water at or below the suggested health effect levels of 455 ng/mL and 4.55 ng/mL, respectively. However, in brominated or chlorinated waters, LODs for SEB increased to approximately 2,500 ng/mL. LODs for ricin increased in chlorinated water, but still remained below the suggested health effect level. In brominated water, the LOD for ricin increased to approximately 2,500 ng/mL. In conclusion, the HHAs tested were less effective at detecting ricin and SEB in disinfected water, as currently configured

    Double-Blind Characterization of Non-Genome-Sequenced Bacteria by Mass Spectrometry-Based Proteomics▿

    No full text
    Due to the possibility of a biothreat attack on civilian or military installations, a need exists for technologies that can detect and accurately identify pathogens in a near-real-time approach. One technology potentially capable of meeting these needs is a high-throughput mass spectrometry (MS)-based proteomic approach. This approach utilizes the knowledge of amino acid sequences of peptides derived from the proteolysis of proteins as a basis for reliable bacterial identification. To evaluate this approach, the tryptic digest peptides generated from double-blind biological samples containing either a single bacterium or a mixture of bacteria were analyzed using liquid chromatography-tandem mass spectrometry. Bioinformatic tools that provide bacterial classification were used to evaluate the proteomic approach. Results showed that bacteria in all of the double-blind samples were accurately identified with no false-positive assignment. The MS proteomic approach showed strain-level discrimination for the various bacteria employed. The approach also characterized double-blind bacterial samples to the respective genus, species, and strain levels when the experimental organism was not in the database due to its genome not having been sequenced. One experimental sample did not have its genome sequenced, and the peptide experimental record was added to the virtual bacterial proteome database. A replicate analysis identified the sample to the peptide experimental record stored in the database. The MS proteomic approach proved capable of identifying and classifying organisms within a microbial mixture

    Iridovirus and microsporidian linked to honey bee colony decline.

    Get PDF
    In 2010 Colony Collapse Disorder (CCD), again devastated honey bee colonies in the USA, indicating that the problem is neither diminishing nor has it been resolved. Many CCD investigations, using sensitive genome-based methods, have found small RNA bee viruses and the microsporidia, Nosema apis and N. ceranae in healthy and collapsing colonies alike with no single pathogen firmly linked to honey bee losses.We used Mass spectrometry-based proteomics (MSP) to identify and quantify thousands of proteins from healthy and collapsing bee colonies. MSP revealed two unreported RNA viruses in North American honey bees, Varroa destructor-1 virus and Kakugo virus, and identified an invertebrate iridescent virus (IIV) (Iridoviridae) associated with CCD colonies. Prevalence of IIV significantly discriminated among strong, failing, and collapsed colonies. In addition, bees in failing colonies contained not only IIV, but also Nosema. Co-occurrence of these microbes consistently marked CCD in (1) bees from commercial apiaries sampled across the U.S. in 2006-2007, (2) bees sequentially sampled as the disorder progressed in an observation hive colony in 2008, and (3) bees from a recurrence of CCD in Florida in 2009. The pathogen pairing was not observed in samples from colonies with no history of CCD, namely bees from Australia and a large, non-migratory beekeeping business in Montana. Laboratory cage trials with a strain of IIV type 6 and Nosema ceranae confirmed that co-infection with these two pathogens was more lethal to bees than either pathogen alone.These findings implicate co-infection by IIV and Nosema with honey bee colony decline, giving credence to older research pointing to IIV, interacting with Nosema and mites, as probable cause of bee losses in the USA, Europe, and Asia. We next need to characterize the IIV and Nosema that we detected and develop management practices to reduce honey bee losses
    corecore