4,539 research outputs found

    Grain textural analysis across a range of glacial facies

    Get PDF

    Biology of the redspotted tonguesole Cynoglossus Zanzibarensis (Pleuronectiformes: Cynoglossidae) on the Agulhas bank, South Africa

    Get PDF
    The biology of the redspotted tonguesole Cynoglossus zanzibarensis, a common African cynoglossid inhabiting the Agulhas Bank, South Africa, is described. Growth studies based on sectioned sagittal otoliths revealed that C. zanzibarensis is relatively fast-growing and long-lived, attaining ages >8 years. Growth in length was rapid in immature fish, fish attaining 56% of their maximum size within their first year. By sexual maturity, fish had attained 28% of their maximum age and 68% of their maximum length. Total length-at-age was best described by the Von Bertalanffy growth model with combined-sex growth described as Lt = 354.78(1–e-0.43 (t+1.17)) mm TL. Sexually dimorphic growth patterns were evident, females attaining larger lengths, but at a slower growth rate than males. Despite the similar mean size of adult fish, the trawl-sampled adult population was dominated by females, with a sex ratio of 1 male:2.4 females. Female C. zanzibarensis mature in their second year of life (275 mm TL), after which they spawn small, pelagic eggs throughout the year. Approximations of the rates of total, natural and fishing mortality were estimated to be 0.62, 0.48 and 0.14 year-1 respectively

    Management of metal-on-metal hip implant patients: Who, when and how to revise?

    Get PDF
    The debate on how best to manage patients with metal-on-metal (MOM) hip implants continues. With over 1 million patients affected worldwide, the impact is far reaching. The majority of the aggressive failures of MOM hip implants have been dealt with by revision hip surgery, leaving patients with a much more indolent pattern of failure of devices that have been in situ for more than 10 years. The longer-term outcome for such patients remains unknown, and much debate exists on how best to manage these patients. Regulatory guidance is available but remains open to interpretation due to the lack of current evidence and long-term studies. Metal ion thresholds for concern have been suggested at 7 ppb for hip resurfacing arthroplasty and below this level for large diameter total hip arthroplasties. Soft tissue changes including pseudotumours and muscle atrophy have been shown to progress, but this is not consistent. New advanced imaging techniques are helping to diagnose complications with metal hips and the reasons for failure, however these are not widely available. This has led to some centres to tackle difficult cases through multidisciplinary collaboration, for both surgical management decisions and also follow-up decisions. We summarise current evidence and consider who is at risk, when revision should be undertaken and how patients should be managed

    Introducing new joint replacements to clinical practice.

    Get PDF
    Requires collaboration between clinicians and regulators, together with comprehensive surveillance dat

    Irish drug abusers II: their psychological characteristics.

    Get PDF
    This is the second in a series of 3 articles based on a study of a cohort of Irish drug abusers. This article attempts to identify the psychological traits of drug abusers within the cohort. The cohort consists of 100 drug abusers who attend a drug advisory and treatment centre in Dublin for the first time between November 1977 and February 1979. Three psychosocial, scales (GEFT, NSQ, and PFS) were administered to each subject. Overall, the results indicate that subjects who participated in the study, while of average or above average intelligence, were poorly psychologically adjusted, characterised by a poor sense of identity, a high level of suggestibility and a tendency towards emotional dependence. Their overall level of intelligence was within or above the normal range

    Self-Reported Neurotoxic Symptoms in Hip Arthroplasty Patients With Highly Elevated Blood Cobalt: A Case-Control Study

    Get PDF
    OBJECTIVES: This study aimed to investigate the prevalence of self-reported neurotoxicity and cognitive defects in hip replacement patients with markedly raised blood cobalt. METHODS: Case group comprised 53 patients with metal-on-metal (MoM) implants and a history of blood Co ≥20 μg/L for a median of 3 years (interquartile range, 2-5 years). The control group comprised 53 patients with ceramic-on-ceramic prostheses and blood Co <1 μg/L. Median age was 67 years (interquartile range, 60-74 years). The participants completed the Neurotoxic Symptom Checklist-60, Diabetic Neuropathy Score, Douleur Neuropathique-10, and Systemic Symptom Checklist, and underwent the Mini-Mental State Examination. RESULTS: The MoM and ceramic-on-ceramic groups were compared, the results were as follows: Neurotoxic Symptom Checklist-60 (median): cognitive defects (2.0 versus 1.9; P = 0.002), chest complaints (1.3 versus 1.3; P = 0.042), balance disturbances (1.3 versus 1.0; P < 0.001), sleep disturbances (2.7 versus 2.0; P = 0.004), mood disorders (2.0 versus 1.5; P = 0.001), sensorimotor disorders (1.6 versus 1.2; P < 0.001), physical complaints (2.0 versus 1.4; P = 0.009), fatigue (2.0 versus 1.6; P = 0.001), and total score (108 versus 90; P < 0.001); abnormal Diabetic Neuropathy Score/Douleur Neuropathique-10 (%): 60.3/13.2 versus 24.5/1.9 (P < 0.001/P = 0.028). Systemic Symptom Checklist (in percent): feeling cold (37.7 versus 17; P = 0.01), weight gain (18.9 versus 1.9; P = 0.008), metallic taste (26.4 versus 3.8; P = 0.002), worsening eyesight (37.7 versus 15.1; P = 0.008) and hearing (24.5 versus 7.5; 0.032), ankle swelling (32.1 versus 7.5; P = 0.002), shortness of breath on exertion (9.4 versus 5.7; P = 0.015), and generalized rash (28.3 versus 7.5; P = 0.01); and Mini-Mental State Examination (median): 29 versus 30 (P = 0.017). Patients in the MoM group were aware of their high cobalt levels and displayed a higher tendency to overreport symptoms (P < 0.001), which could have contributed to the higher scores. CONCLUSIONS: Frequency of reporting a number of symptoms was markedly higher in MoM patients, but clinically significant neurotoxicity was not observed (possibly due to the short exposure to elevated cobalt). Patients with repeated blood Co ≥20 μg/L measurements should be questioned about possible systemic health complaints at follow-up

    Metal-on-metal total hip arthroplasty: does increasing modularity affect clinical outcome?

    Get PDF
    BACKGROUND: Modularity of metal-on-metal (MoM) implants has come under scrutiny due to concerns regarding additional sources of metal debris. This study is a retrieval analysis of implants from the same manufacturer with the same MoM bearing surface. The difference between the implants was presence or absence of modular junctions. METHODS: This is a retrospective study of 31 retrieved implants from 31 patients who received a Conserve Wright Medical MoM hip prosthesis. The 31 implants consisted of 16 resurfacings and 15 implants with modular junctions; 4 conventional THAs and 11 modular-neck THAs. RESULTS: 43% of pre-revision MRI scans performed on resurfacing implants and 91% performed on the modular implants illustrated evidence of an adverse local tissue reaction. There was no difference in pre-revision blood metal ion levels or bearing surface wear between the resurfacings and modular implants. The neck-head tapers of the modular group showed low levels of material loss. However, the neck-stem tapers showed increased severity of corrosion and material loss. CONCLUSIONS: The modular implants had an increased incidence of adverse local tissue reaction. This could be related to the presence of modular junctions, particular the neck-stem junction which showed increased susceptibly to corrosion

    Strain-engineered manufacturing of freeform carbon nanotube microstructures.

    Get PDF
    The skins of many plants and animals have intricate microscale surface features that give rise to properties such as directed water repellency and adhesion, camouflage, and resistance to fouling. However, engineered mimicry of these designs has been restrained by the limited capabilities of top-down fabrication processes. Here we demonstrate a new technique for scalable manufacturing of freeform microstructures via strain-engineered growth of aligned carbon nanotubes (CNTs). Offset patterning of the CNT growth catalyst is used to locally modulate the CNT growth rate. This causes the CNTs to collectively bend during growth, with exceptional uniformity over large areas. The final shape of the curved CNT microstructures can be designed via finite element modeling, and compound catalyst shapes produce microstructures with multidirectional curvature and unusual self-organized patterns. Conformal coating of the CNTs enables tuning of the mechanical properties independently from the microstructure geometry, representing a versatile principle for design and manufacturing of complex microstructured surfaces.This is the author accepted manuscript. The final published version can be found in Nature Communications here: http://www.nature.com/ncomms/2014/140729/ncomms5512/full/ncomms5512.html. This paper will be under embargo until 29/1/15

    Reference values for volume, fat content and shape of the hip abductor muscles in healthy individuals from Dixon MRI

    Get PDF
    Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle, as they are greatly involved in human daily activities. Fatty infiltration and muscle atrophy are associated with loss of strength, loss of mobility and hip disease. However, these variables have not been widely studied in this muscle group. We aimed to characterize the hip abductor muscles in a group of healthy individuals to establish reference values for volume, intramuscular fat content and shape of this muscle group. To achieve this, we executed a cross-sectional study using Dixon MRI scans of 51 healthy subjects. We used an automated segmentation method to label GMAX, GMED, GMIN and TFL muscles, measured normalized volume (NV) using lean body mass, fat fraction (FF) and lean muscle volume for each subject and computed non-parametric statistics for each variable grouped by sex and age. We measured these variables for each axial slice and created cross-sectional area and FF axial profiles for each muscle. Finally, we generated sex-specific atlases with FF statistical images. We measured median (IQR) NV values of 12.6 (10.8-13.8), 6.3 (5.6-6.7), 1.6 (1.4-1.7) and 0.8 (0.6-1.0) cm3/kg for GMAX, GMED, GMIN and TFL, and median (IQR) FF values of 12.3 (10.1-15.9)%, 9.8 (8.6-11.2)%, 10.0 (9.0-12.0)% and 10.2 (7.8-13.5)% respectively. FF values were significantly higher for females for the four muscles (p < 0.01), but there were no significant differences between the two age groups. When comparing individual muscles, we observed a significantly higher FF in GMAX than in the other muscles. The reported novel reference values and axial profiles for volume and FF of the hip abductors, together with male and female atlases, are tools that could potentially help to quantify and detect early the deteriorating effects of hip disease or sarcopenia
    • …
    corecore