97 research outputs found
Tapering Enhanced Stimulated Superradiant Oscillator
In this paper, we present a new kind of high power and high efficiency
free-electron laser oscillator based on the application of the tapering
enhanced stimulated superradiant amplification (TESSA) scheme. The main
characteristic of the TESSA scheme is a high intensity seed pulse which
provides high gradient beam deceleration and efficient energy extraction. In
the oscillator configuration, the TESSA undulator is driven by a high
repetition rate electron beam and embedded in an optical cavity. A
beam-splitter is used for outcoupling a fraction of the amplified power and
recirculate the remainder as the intense seed for the next electron beam pulse.
The mirrors in the oscillator cavity refocus the seed at the undulator entrance
and monochromatize the radiation. In this paper we discuss the optimization of
the system for a technologically relevant example at 1 m using a 1~MHz
repetition rate electron linac starting with an externally injected igniter
pulse.Comment: 24 pages, 13 figure
Amp\`ere-Class Pulsed Field Emission from Carbon-Nanotube Cathodes in a Radiofrequency Resonator
Pulsed field emission from cold carbon-nanotube cathodes placed in a
radiofrequency resonant cavity was observed. The cathodes were located on the
backplate of a conventional -cell resonant cavity operating at
1.3-GHz and resulted in the production of bunch train with maximum average
current close to 0.7 Amp\`ere. The measured Fowler-Nordheim characteristic,
transverse emittance, and pulse duration are presented and, when possible,
compared to numerical simulations. The implications of our results to
high-average-current electron sources are briefly discussed.Comment: 5 pages, 6 figures; submitted to Applied Physics Letter
Upgrades of beam diagnostics in support of emittance-exchange experiments at the Fermilab A0 photoinjector
The possibility of using electron beam phase space manipulations to support a
free-electron laser accelerator design optimization has motivated our research.
An on-going program demonstrating the exchange of transverse horizontal and
longitudinal emittances at the Fermilab A0 photoinjector has benefited recently
from the upgrade of several of the key diagnostics stations. Accurate
measurements of these properties upstream and downstream of the exchanger
beamline are needed. Improvements in the screen resolution term and reduced
impact of the optical system's depth-of-focus by using YAG:Ce single crystals
normal to the beam direction will be described. The requirement to measure
small energy spreads (<10 keV) in the spectrometer and the exchange process
which resulted in bunch lengths less than 500 fs led to other diagnostics
performance adjustments and upgrades as well. A longitudinal to transverse
exchange example is also reported.Comment: 16 p
Electron beam profile imaging in the presence of coherent optical radiation effects
High-brightness electron beams with low energy spread at existing and future
x-ray free-electron lasers are affected by various collective beam
self-interactions and microbunching instabilities. The corresponding coherent
optical radiation effects, e.g., coherent optical transition radiation, render
electron beam profile imaging impossible and become a serious issue for all
kinds of electron beam diagnostics using imaging screens. Furthermore, coherent
optical radiation effects can also be related to intrinsically ultrashort
electron bunches or the existence of ultrashort spikes inside the electron
bunches. In this paper, we discuss methods to suppress coherent optical
radiation effects both by electron beam profile imaging in dispersive beamlines
and by using scintillation imaging screens in combination with separation
techniques. The suppression of coherent optical emission in dispersive
beamlines is shown by analytical calculations, numerical simulations, and
measurements. Transverse and longitudinal electron beam profile measurements in
the presence of coherent optical radiation effects in non-dispersive beamlines
are demonstrated by applying a temporal separation technique.Comment: 12 pages, 11 figures, submitted to Phys. Rev. ST Accel. Beam
Tunable Electron Multibunch Production in Plasma Wakefield Accelerators
Synchronized, independently tunable and focused J-class laser pulses are
used to release multiple electron populations via photo-ionization inside an
electron-beam driven plasma wave. By varying the laser foci in the laboratory
frame and the position of the underdense photocathodes in the co-moving frame,
the delays between the produced bunches and their energies are adjusted. The
resulting multibunches have ultra-high quality and brightness, allowing for
hitherto impossible bunch configurations such as spatially overlapping bunch
populations with strictly separated energies, which opens up a new regime for
light sources such as free-electron-lasers
DESIGN FOR A FAST, XFEL-QUALITY WIRE SCANNER
Abstract RadiaBeam Technologies has designed and manufactured a new wire scanner for high-speed emittance measurements of XFEL-type beams of energy 139 MeV. Using three 25-micron thick tungsten wires, this wire scanner measures vertical and horizontal beam size as well as transverse spatial correlation in one pass. The intensity of the beam at a wire position is determined from emitted bremsstrahlung photons as measured by a BGO scintillator system. The wires are transported on a two-ended support structure moved by a ball-screw linear stage. The doubleended structure reduces vibrations in the wire holder, and the two-bellows design negates the effects of air pressure on the motion. The expected minimum beam size measurable by this system is on the order of 10 microns with 0.1-micron accuracy. To achieve this, new algorithms are presented that reduce the effect of the non-zero thickness of the wire on the wire scan output. In addition, novel calculations are presented for determining the elliptical geometric parameters (vertical and horizontal beam size and correlation, or alternatively, the axis lengths and rotation) of the beam from the wire scanner measurements
High field hybrid photoinjector electron source for advanced light source applications
The production of high spectral brilliance radiation from electron beam sources depends critically on the electron beam qualities. One must obtain very high electron beam brightness, implying simultaneous high peak current and low emittance. These attributes are enabled through the use of very high field acceleration in a radio-frequency (rf) photoinjector source. Despite the high fields currently utilized, there is a limit on the achievable peak current in high brightness operation, in the range of tens of Ampere. This limitation can be overcome by the use of a hybrid standing wave/traveling wave structure; the standing wave portion provides acceleration at a high field from the photocathode, while the traveling wave part yields strong velocity bunching. This approach is explored here in a C-band scenario, at field strengths (>100 MV/m) at the current state-of-the-art. It is found that one may arrive at an electron beam with many hundreds of Amperes with well-sub-micron normalized emittance. This extremely compact injector system also possesses attractive simplification of the rf distribution system by eliminating the need for an rf circulator. We explore the use of this device in a compact 400 MeV-class source, driving both inverse Compton scattering and free-electron laser radiation sources with unique, attractive properties
An Ultra-Compact X-Ray Free-Electron Laser
In the field of beam physics, two frontier topics have taken center stage due
to their potential to enable new approaches to discovery in a wide swath of
science. These areas are: advanced, high gradient acceleration techniques, and
x-ray free electron lasers (XFELs). Further, there is intense interest in the
marriage of these two fields, with the goal of producing a very compact XFEL.
In this context, recent advances in high gradient radio-frequency cryogenic
copper structure research have opened the door to the use of surface electric
fields between 250 and 500 MV/m. Such an approach is foreseen to enable a new
generation of photoinjectors with six-dimensional beam brightness beyond the
current state-of-the-art by well over an order of magnitude. This advance is an
essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one
may accelerate these bright beams to GeV scale in less than 10 meters. Such an
injector, when combined with inverse free electron laser-based bunching
techniques can produce multi-kA beams with unprecedented beam quality,
quantified by ~50 nm-rad normalized emittances. These beams, when injected into
innovative, short-period (1-10 mm) undulators uniquely enable UC-XFELs having
footprints consistent with university-scale laboratories. We describe the
architecture and predicted performance of this novel light source, which
promises photon production per pulse of a few percent of existing XFEL sources.
We review implementation issues including collective beam effects, compact
x-ray optics systems, and other relevant technical challenges. To illustrate
the potential of such a light source to fundamentally change the current
paradigm of XFELs with their limited access, we examine possible applications
in biology, chemistry, materials, atomic physics, industry, and medicine which
may profit from this new model of performing XFEL science.Comment: 80 pages, 24 figure
Generation and acceleration of electron bunches from a plasma photocathode
Plasma waves generated in the wake of intense, relativistic laser1,2 or particle beams3,4 can accelerate electron bunches to gigaelectronvolt energies in centimetre-scale distances. This allows the realization of compact accelerators with emerging applications ranging from modern light sources such as the free-electron laser to energy frontier lepton colliders. In a plasma wakefield accelerator, such multi-gigavolt-per-metre wakefields can accelerate witness electron bunches that are either externally injected5,6 or captured from the background plasma7,8. Here we demonstrate optically triggered injection9–11 and acceleration of electron bunches, generated in a multi-component hydrogen and helium plasma employing a spatially aligned and synchronized laser pulse. This ‘plasma photocathode’ decouples injection from wake excitation by liberating tunnel-ionized helium electrons directly inside the plasma cavity, where these cold electrons are then rapidly boosted to relativistic velocities. The injection regime can be accessed via optical11 density down-ramp injection12–16 and is an important step towards the generation of electron beams with unprecedented low transverse emittance, high current and 6D-brightness17. This experimental path opens numerous prospects for transformative plasma wakefield accelerator applications based on ultrahigh-brightness beams
Beam physics research with the IOTA electron lens
The electron lens in the Fermilab Integrable Optics Test Accelerator (IOTA) will enable new research in nonlinear integrable optics, space-charge compensation, electron cooling, and the stability of intense beams. This research addresses scientific questions on high-brightness beams and operational challenges of high-power accelerators for nuclear and particle physics. We review the roles that electron lenses play in this field and the physical principles behind their applications. The design criteria and specifications for the IOTA storage ring and electron lens are then discussed. We conclude with a description of the components of the apparatus
- …