64 research outputs found

    Concomitant Right Ventricular Outflow Tract Cryoablation during Pulmonary Valve Replacement in a Patient with Tetralogy of Fallot

    Get PDF
    A 38-year-old female patient with a history of tetralogy of Fallot repair at 10 years of age underwent pulmonary valve replacement with a mechanical prosthesis, tricuspid annuloplasty, and right ventricular outflow tract cryoablation due to pulmonary regurgitation, tricuspid regurgitation, and multiple premature ventricular contractions with sustained ventricular tachycardia. After surgery, she had an uneventful postoperative course with arrhythmia monitoring. She was discharged without incident, and a follow-up Holter examination showed a decrease in the number of ventricular ectopic beats from 702 to 41.ope

    The First Pediatric Heart Transplantation Bridged by a Durable Left Ventricular Assist Device in Korea

    Get PDF
    Treatment options for children with end-stage heart failure are limited. We report the first case of a successful pediatric heart transplantation bridged with a durable left ventricular assist device in Korea. A 10-month-old female infant with dilated cardiomyopathy and left ventricular non-compaction was listed for heart transplantation. During the waiting period, the patient's status deteriorated. Therefore, we decided to provide support with a durable left ventricular assist device as a bridge to transplantation. The patient was successfully bridged to heart transplantation with effective support and without any major adverse events.ope

    Tricuspid Valve Re-Repair in Ebstein Anomaly Using the Cone Technique

    Get PDF
    The management of recurrent tricuspid regurgitation after tricuspid valve repair in patients with Ebstein anomaly is difficult, and tricuspid valve replacement is most commonly performed in such patients. We report two cases of recurrent tricuspid regurgitation in patients with Ebstein anomaly that were successfully re-repaired using the cone technique. The cone repair technique is a useful surgical method for reconstructing a competent tricuspid valve, and can be applied in patients who have undergone previous tricuspid valve repair.ope

    Pediatric Ventricular Assist Device

    Get PDF
    There have been great advances in ventricular assist device (VAD) treatment for pediatric patients with advanced heart failure. VAD support provides more time for the patient in the heart transplant waiting list. Augmented cardiac output improves heart failure symptoms, end-organ function, and general condition, and consequently provides beneficial effects on post-transplant outcomes. Miniaturized continuous flow devices are more widely adopted for pediatric patient with promising results. For infants and small children, still paracorporeal pulsatile device is the only option for long-term support. Younger age, congenital heart disease, biventricular support, patient's status and end-organ dysfunction at the time of implantation are risks for poor outcomes. Patient selection, timing of implantation, and selection of device for each patient are critical for optimal clinical outcomes.ope

    Reference Intervals of Thromboelastometric Evaluation of Coagulation in Pediatric Patients with Congenital Heart Diseases: A Retrospective Investigation

    Get PDF
    BACKGROUND Rotational thromboelastometry (ROTEM®) is a point-of-care test for coagulation, enabling physicians to make a swift decision. The aim of this investigation was to establish reference intervals of thromboelastometric evaluation for coagulation in pediatric patients with congenital heart diseases (CHD). MATERIAL AND METHODS As baseline data, 3 assays of ROTEM® (INTEM, EXTEM, and FIBTEM) were measured after anesthesia induction. ROTEM® parameters were clotting time (CT), amplitude at 10 min (A10), clot formation time (CFT), a angle, maximal clot firmness (MCF), clot lysis index at 60 min (LI60), and maximal clot elasticity (MCE). As age is a well-known factor for maturation, age groups were determined as follows; 1) <1 month, 2) 1-3 months, 3) 4-12 months, 4) 1-3 years, 5) 4-6 years, 6) 7-12 years, and 7) 13-16 years. Reference limits representing 95% of distribution of ROTEM® parameters and 90% confidence intervals of upper and lower reference limits were calculated. RESULTS The data of 413 patients were analyzed. Although INTEM CT was prolonged, significantly shorter CT and CFT, steeper α, and greater A10, MCF, and MCE were shown in patients age <3 months compared to older children. CONCLUSIONS Reference intervals of thromboelastometric evaluation for coagulation from pediatric patients with CHD were shown to have similar pattern to those obtained from healthy pediatric patients. Pediatric patients with CHD, even with cyanosis, were demonstrated to have functionally intact coagulation profile before surgery.ope

    Left Atrial Decompression by Percutaneous Left Atrial Venting Cannula Insertion during Venoarterial Extracorporeal Membrane Oxygenation Support

    Get PDF
    Patients with venoarterial extracorporeal membrane oxygenation (ECMO) frequently suffer from pulmonary edema due to left ventricular dysfunction that accompanies left heart dilatation, which is caused by left atrial hypertension. The problem can be resolved by left atrium (LA) decompression. We performed a successful percutaneous LA decompression with an atrial septostomy and placement of an LA venting cannula in a 38-month-old child treated with venoarterial ECMO for acute myocarditis.ope

    Emergency Pulmonary Artery–to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair

    Get PDF
    A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This shunt provided immediate relief of suprasystemic pulmonary hypertension and the resultant low cardiac output.ope

    Platelet Reactivity and Outcomes after Off-Pump Coronary Surgery in Acute Coronary Syndrome Patients

    Get PDF
    Ischemic and hemorrhagic complications are major determinants of survival in acute coronary syndrome (ACS) patients undergoing coronary surgery. We investigated the association of preoperative platelet reactivity to P2Y12 antagonists with ischemic and hemorrhagic complications after Off-Pump Coronary Artery Bypass surgery (OPCAB) in ACS patients who received dual anti-platelet therapy (DAPT) within 5 days prior to surgery. This prospective, observational study with 177 patients compared the incidence of perioperative major bleeding and major adverse cardiac events (MACEs) in relation to the tertile distribution of the % inhibitory response to P2Y12 antagonists, as measured by a thromboelastography platelet mapping assay. The incidences of perioperative major bleeding and MACEs were similar in relation to the tertile distribution of inhibitory response to P2Y12 antagonists. The % inhibitory responses to P2Y12 antagonists between patients who did or did not exhibit MACEs, and with or without major bleeding, were 58 ± 20% and 56 ± 20% (p = 0.578) and 57 ± 19% and 56 ± 21% (p = 0.923), respectively. In ACS patients who received DAPT close to OPCAB, the platelet inhibitory response to P2Y12 antagonists was not associated with ischemic or hemorrhagic complications. OPCAB may obviate the need for routine platelet function testing for ACS patients requiring DAPT and surgical revascularization. Clinical Registration Number: NCT02184884.ope

    Influence of Mild Thyroid Dysfunction on Outcomes after Off-Pump Coronary Artery Bypass Surgery

    Get PDF
    We retrospectively evaluated the association between preoperative mild thyroid dysfunction (subclinical hypothyroidism [SCH] or low triiodothyronine [T3] syndrome) and outcomes in patients who underwent off-pump coronary surgery (OPCAB). Further, 800 patients (2015-2020) were divided into euthyroid, low T3, and SCH groups. The primary outcome assessed the association with composite endpoints (myocardial infarction, prolonged mechanical ventilation [&gt;24 h], acute kidney injury, and 30-day/in-hospital mortality). The secondary outcome assessed the association with long-term mortality and 10% and 8% of the patients exhibited low T3 and SCH, respectively. Incidences of composite endpoints were significantly higher in the low T3 and SCH groups versus the euthyroid group (50.6%, 45.2%, 17.4%, respectively, p &lt; 0.001). Multivariable regression analysis revealed chronic kidney disease, anemia, EuroSCORE, low T3, and SCH as independent risk factors of composite endpoints. The long-term mortality rate (median follow-up, 30 months) was higher in the low T3 and SCH groups than in the euthyroid group (9.6%, 11.3%, 2.4%, respectively, p &lt; 0.001). In the absence of overt thyroid dysfunction, low T3 and SCH were associated with increased risk of adverse outcomes after OPCAB. Moreover, the adverse influences of low T3 and SCH seem to extend to long-term mortality, implying that routine thyroid function tests may enhance accurate risk stratification.ope

    Early and Midterm Outcome of Redo Coronary Artery Bypass Grafting: On-Pump versus Off-Pump Bypass

    Get PDF
    Background: Redo coronary artery bypass grafting (CABG) is still associated with increased morbidity and mortality as compared to the first-time operation. Further, the application of the off-pump technique to redo CABG is limited due to technical difficulties. The aim of this retrospective study was to analyze early and midterm results after redo CABG and compare the outcome of redo on-pump and off-pump CABG. Methods: From June 1996 to October 2011, elective redo CABG was performed in 32 patients. Mean age was 64.8 years (on pump 64.3 years vs. off pump 65.5 years; p=0.658), and 21 patients were male. Among these patients, 14 (43.8%) underwent on-pump CABG, and 18 (56.2%) underwent off-pump CABG. Results: Internal thoracic artery was used in 22 patients (68.8%), and total arterial revascularization was achieved in 17 patients (53.1%). The average number of distal anastomoses was 2.13, and the rate of incomplete revascularization was 43.8%. The rate of total arterial revascularization was higher in the off-pump group (14.3% vs. 83.3%, p<0.001), and the use of saphenous vein graft was more in the on-pump group (78.6% vs. 16.7%, p<0.001). Overall hospital mortality was 3.1% (n=1) and was comparable in both groups (on pump 7.1% vs. off pump 0%; p=0.249). Postoperative complications occurred in 9 patients (64.2%), and the rate of complications was high in the on-pump group without statistical significance (64.2% vs. 33.3%, p=0.082). The mean follow-up duration was 5.4 years, and overall survival at 10 years was 86.0%±10.5%. There was no significant difference in the 10-year survival rate between the two groups (79.6% vs. 100%, p=0.225). Conclusion: Redo CABG can be safely performed with acceptable mortality. Redo off-pump coronary artery bypass is feasible with low mortality and morbidity, comparable target vessel bypass grafting, and long-term survival. The off-pump technique might be considered a safe option for redo CABG in high-risk patients.ope
    corecore