    Impediment in upper airway stabilizing forces assessed by phrenic nerve stimulation in sleep apnea patients

    Get PDF
    BACKGROUND: The forces developed during inspiration play a key role in determining upper airway stability and the occurrence of nocturnal breathing disorders. Phrenic nerve stimulation applied during wakefulness is a unique tool to assess Upper airway dynamic properties and to measure the overall mechanical effects of the inspiratory process on UA stability. OBJECTIVES: To compare the flow/pressure responses to inspiratory and expiratory twitches between sleep apnea subjects and normal subjects. METHODS: Inspiratory and expiratory twitches using magnetic nerve stimulation completed in eleven untreated sleep apnea subjects and ten normal subjects. RESULTS: In both groups, higher flow and pressure were reached during inspiratory twitches. The two groups showed no differences in expiratory twitch parameters. During inspiration, the pressure at which flow-limitation occurred was more negative in normals than in apneic subjects, but not reaching significance (p = 0.07). The relationship between pharyngeal pressure and flow adequately fitted with a polynomial regression model providing a measurement of upper airway critical pressure during twitch. This pressure significantly decreased in normals from expiratory to inspiratory twitches (-11.1 ± 1.6 and -15.7 ± 1.0 cm H(2)O respectively, 95% CI 1.6–7.6, p < 0.01), with no significant difference between the two measurements in apneic subjects. The inspiratory/expiratory difference in critical pressure was significantly correlated with the frequency of nocturnal breathing disorders. CONCLUSION: Inspiratory-related upper airway dilating forces are impeded in sleep apnea patients

    Clinical Guidelines for the Use of Unattended Portable Monitors in the Diagnosis of Obstructive Sleep Apnea in Adult Patients

    Get PDF
    Based on a review of literature and consensus, the Portable Monitoring Task Force of the American Academy of Sleep Medicine (AASM) makes the following recommendations: unattended portable monitoring (PM) for the diagnosis of obstructive sleep apnea (OSA) should be performed only in conjunction with a comprehensive sleep evaluation. Clinical sleep evaluations using PM must be supervised by a practitioner with board certification in sleep medicine or an individual who fulfills the eligibility criteria for the sleep medicine certification examination. PM may be used as an alternative to polysomnography (PSG) for the diagnosis of OSA in patients with a high pretest probability of moderate to severe OSA. PM is not appropriate for the diagnosis of OSA in patients with significant comorbid medical conditions that may degrade the accuracy of PM. PM is not appropriate for the diagnostic evaluation of patients suspected of having comorbid sleep disorders. PM is not appropriate for general screening of asymptomatic populations. PM may be indicated for the diagnosis of OSA in patients for whom in-laboratory PSG is not possible by virtue of immobility, safety, or critical illness. PM may also be indicated to monitor the response to non-CPAP treatments for sleep apnea. At a minimum, PM must record airflow, respiratory effort, and blood oxygenation. The airflow, effort, and oximetric biosensors conventionally used for in-laboratory PSG should be used in PM. The Task Force recommends that PM testing be performed under the auspices of an AASM-accredited comprehensive sleep medicine pro- gram with written policies and procedures. An experienced sleep technologist/technician must apply the sensors or directly educate patients in sensor application. The PM device must allow for display of raw data with the capability of manual scoring or editing of automated scoring by a qualified sleep technician/technologist. A board certified sleep specialist, or an individual who fulfills the eligibility criteria for the sleep medicine certification examination, must review the raw data from PM using scoring criteria consistent with current published AASM standards. Under the conditions specified above, PM may be used for unattended studies in the patient’s home. A follow-up visit to review test results should be performed for all patients undergoing PM. Negative or technically in- adequate PM tests in patients with a high pretest probability of moderate to severe OSA should prompt in-laboratory polysomnography

    Novel concepts in virally induced asthma

    Get PDF
    Viruses are the predominant infectious cause of asthma exacerbations in the developed world. In addition, recent evidence strongly suggests that viral infections may also have a causal role in the development of childhood asthma. In this article, we will briefly describe the general perception of how the link between infections and asthma has changed over the last century, and then focus on very recent developments that have provided new insights into the contribution of viruses to asthma pathogenesis. Highlighted areas include the contribution of severe early life viral infections to asthma inception, genetic determinants of severe viral infections in infancy, the differences in innate and adaptive immune system cytokine responses to viral infection between asthmatic and nonasthmatic subjects, and a potential vaccine strategy to prevent severe early life virally-induced illness

    Reliability of home CPAP titration with different automatic CPAP devices

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420).</p> <p>Methods</p> <p>Sixteen untreated obstructive sleep apnea patients were randomly allocated to one of the 3 tested machines for a one-week home titration trial in a crossover design with a 10 days washout period between trials.</p> <p>Results</p> <p>The median pressure value was significantly lower with machine GK 420 (5.9 +/- 1.8 cm H<sub>2</sub>O) than with the other devices both after one night and one week of CPAP titration (7.4 +/- 1.3 and 6.6 +/- 1.9 cm H<sub>2</sub>O). The maximal pressure obtained over the one-week titration was significantly higher with Remstar Auto (12.6 +/- 2.4 cm H<sub>2</sub>O, Mean +/- SD) than with the two other ones (10.9 +/- 1.0 and 11.0 +/- 2.4 cm H<sub>2</sub>O). The variance in pressure recommendation significantly differed between the three machines after one night and between Autoset Spirit and the two other machines after 1 week.</p> <p>Conclusion</p> <p>Pressure behaviour and pressure recommendation significantly differ between Auto CPAP machines both after one night and one week of home titration.</p