2 research outputs found

    Experimental assessment of inter-centre variation in stopping-power and range prediction in particle therapy

    Get PDF
    Purpose: Experimental assessment of inter-centre variation and absolute accuracy of stopping-power ratio (SPR) prediction within 17 particle therapy centres of the European Particle Therapy Network. Material and methods: A head and body phantom with seventeen tissue-equivalent materials were scanned consecutively at the participating centres using their individual clinical CT scan protocol and translated into SPR with their in-house CT-number-to-SPR conversion. Inter-centre variation and absolute accuracy in SPR prediction were quantified for three tissue groups: lung, soft tissues and bones. The integral effect on range prediction for typical clinical beams traversing different tissues was determined for representative beam paths for the treatment of primary brain tumours as well as lung and prostate cancer. Results: An inter-centre variation in SPR prediction (2 sigma) of 8.7%, 6.3% and 1.5% relative to water was determined for bone, lung and soft-tissue surrogates in the head setup, respectively. Slightly smaller variations were observed in the body phantom (6.2%, 3.1%, 1.3%). This translated into inter-centre variation of integral range prediction (2 sigma) of 2.9%, 2.6% and 1.3% for typical beam paths of prostate-, lung-and primary brain-tumour treatments, respectively. The absolute error in range exceeded 2% in every fourth participating centre. The consideration of beam hardening and the execution of an independent HLUT validation had a positive effect, on average. Conclusion: The large inter-centre variations in SPR and range prediction justify the currently clinically used margins accounting for range uncertainty, which are of the same magnitude as the inter-centre variation. This study underlines the necessity of higher standardisation in CT-number-to-SPR conversion. (C) 2021 The Authors. Published by Elsevier B.V

    Spin-lock MR enhances the detection sensitivity of superparamagnetic iron oxide particles

    Get PDF
    To evaluate spin-lock MR for detecting superparamagnetic iron oxides and compare the detection sensitivity of quantitative T1ρ with T2 imaging. In vitro experiments were performed to investigate the influence of iron oxide particle size and composition on T1ρ . These comprise T1ρ and T2 measurements (B0 = 1.41T) of agar (2%) with concentration ranges of three different iron oxide nanoparticles (IONs) (Sinerem, Resovist, and ION-Micelle) and microparticles of iron oxide (MPIO). T1ρ dispersion was measured for a range of spin-lock amplitudes (γB1 = 6.5-91 kHz). Under relevant in vivo conditions (B0 = 9.4T; γB1 = 100-1500 Hz), T1ρ and T2 mapping of the liver was performed in seven mice pre- and 24 h postinjection of Sinerem. Addition of iron oxide nanoparticles decreased T1ρ as well as the native T1ρ dispersion of agar, leading to increased contrast at high spin-lock amplitudes. Changes of T1ρ were highly linear with iron concentration and much larger than T2 changes. MPIO did not show this effect. In vivo, a decrease of T1ρ was observed with no clear influence on T1ρ dispersion. By suppression of T1ρ dispersion, iron oxide nanoparticles cause enhanced T1ρ contrast compared to T2 . The underlying mechanism appears to be loss of lock. Spin-lock MR is therefore a promising technique for sensitive detection of iron oxide contrast agent
    corecore