10 research outputs found

    Minor influence of humeral component size on torsional stiffness of the Souter-Strathclyde total elbow prosthesis

    Get PDF
    The use of Souter-Strathclyde total elbow prostheses is a well-studied replacement therapy for reconstruction of the elbow, but loosening of the humeral component is still of concern at long-term follow-up. In this study we looked at the effect of humeral component size and bone mineral density with respect to the bone size, torsional stiffness and torque to failure in cadaveric bones. Fourteen cadaveric humeri were available for testing purposes and four different humeral component size categories were used. First, we calculated the bone quality using dual-energy X-ray absorptiometry (DEXA). The torsional stiffness of the prosthetic humeri was measured during two mechanical tests: Firstly, the applied torque was recorded during a torsion fatigue test. The change of torsional stiffness between the tenth and last cycle was calculated. Secondly, a simple torsion test was performed and the torque to failure was recorded. No significant differences in outcome were seen between sizes of humeral components, even after correction for the bone size. Torsional stiffness and torque to failure were significantly correlated with bone mineral density and not with component size. In conclusion, bone quality seems to be a major eminent factor in the fixation of the humeral component in elbow replacement surgery

    The effect of injectable biocompatible elastomer (PDMS) on the strength of the proximal fixation of endovascular aneurysm repair grafts: An in vitro study

    Get PDF
    PurposeOne of the major concerns in the long-term success of endovascular aneurysm repair (EVAR) is stent graft migration, which can cause type I endoleak and even aneurysm rupture. Fixation depends on the mechanical forces between the graft and both the aortic neck and the blood flow. Therefore, there are anatomical restrictions for EVAR, such as short and angulated necks. To improve the fixation of EVAR grafts, elastomer (PDMS) can be injected in the aneurysm sac. The support given by the elastomer might prevent dislocation and migration of the graft. The aim of this study was to measure the influence of an injectable biocompatible elastomer on the fixation strength of different EVAR grafts in an in vitro model.MethodsThe proximal part of three different stent grafts was inserted in a bovine artery with an attached latex aneurysm. The graft was connected to a tensile testing machine, applying force to the proximal fixation, while the artery with the aneurysm was fixated to the setup. The force to obtain graft dislodgement (DF) from the aorta was recorded in Newtons (N). Three different proximal seal lengths (5, 10, and 15 mm) were evaluated. The experiments were repeated after the space between the graft and the latex aneurysm was filled with the elastomer. Independent sample ttests were used for the comparison between the DF before and after elastomer treatment for each seal length.ResultsThe mean DF (mean ± SD) of all grafts without elastomer sac filling for a proximal seal length of 5, 10, and 15 mm were respectively, 4.4 ± 3.1 N, 12.2 ± 10.6 N, and 15.1 ± 6.9 N. After elastomer sac filling, the dislodgement forces increased significantly (P < .001) to 20.9 ± 3.8 N, 31.8 ± 9.8 N, and 36.0 ± 14.1 N, respectively.ConclusionsThe present study shows that aneurysm sac filling may have a role as an adjuvant procedure to the present EVAR technique. The strength of the proximal fixation of three different stent grafts increases significantly in this in vitro setting. Further in vivo research must be done to see if this could facilitate the treatment of aneurysms with short infrarenal necks.Clinical RelevanceStent graft migration and endoleak due to suboptimal fixation are major drawbacks of currently available stent grafts. Optimizing the proximal fixation by peri-graft elastomer aneurysm sac filling may lead to lower incidence of graft migration and endoleak. It might make endovascular aneurysm repair available to larger group of patients with an abdominal aortic aneurysm

    A retrospective analysis of bilateral fractures over sixteen years: localisation and variation in treatment of second hip fractures

    Get PDF
    The aim of this study was the evaluation of contralateral hip fractures after a previous hip fracture. For this retrospective analysis patients were selected from the database of the LUMC, a teaching hospital in the south-west of the Netherlands. We analyzed all patients with a second fracture of a hip between 1992 and 2007. The exclusion criteria were high impact trauma and patients with diseases or medication known to have a negative effect on bone metabolism. A total of 1,604 hip fractures were identified. The possible predictive factors for the second fracture and descriptive statistics related to surgery (Hb and HT before and after the operation, total amount of intra- and postoperative blood loss, type of osteosynthesis, complications, time of death after the last fracture, time between arrival in the hospital and operation and hospital stay for both fractures) were recorded. A total of 32 second hip fractures were identified (2%) at a mean of 27.5 (SD 28.9) months after the initial hip fracture. The mean age at the first fracture was 77.2 years (SD 11.7), and 27 of 32 patients were female. Of these 32 patients (64 bilateral hip fractures), 32 fractures were intracapsular (1 femoral neck, 31 subcapital) and 32 were extracapsular fractures (6 subtrochanteric, 26 transtrochanteric). Although 24 of the 32 patients had identical first and second hip fractures, only eight out of 32 hips were treated with the same implants. There was a significant difference in Singh index between both hips at the time of the first fracture. There was also a significant difference in Singh index between the hip which was not fractured compared with its subsequent index when it was broken. All other studied patient and fracture characteristics were not significantly different. In this population the percentage of second hip fractures was relatively low compared to other studies. The choice of implants in this study shows that implants were chosen randomly. Because there is a significant difference in the Singh index during first and second hip fracture, osteoporosis medication might help reduce the incidence of second hip fractures

    The upside down Gore Excluder contralateral leg without extracorporeal predeployment for aortic or iliac aneurysm exclusion

    Get PDF
    Endovascular techniques, including branched devices to preserve the internal iliac artery are evolving rapidly, but in cases in which the diameter of the proximal sealing zone is larger than that of the distal sealing zone, a reversed tapered device is needed. We describe the off label use of the Gore Excluder contralateral leg endoprosthesis in an upside down configuration to accommodate this diameter mismatch. The preinsertion technical steps of stent graft preparation, which do not require extracorporeal predeployment, are described in detail. As such, an aneurysm of the internal iliac artery and a saccular abdominal aortic aneurysm were successfully excluded

    Aortic Customize: A new alternative endovascular approach to aortic aneurysm repair using injectable biocompatible elastomer. An in vitro study

    Get PDF
    PurposeAortic Customize is a new concept for endovascular aortic aneurysm repair in which a non polymerized elastomer is injected to fill the aneurysm sac around a balloon catheter. The aim of this in vitro study was to investigate the extent of aneurysm wall stress reduction by the presence of a noncompliant elastomer cuff.MethodsA thin-walled latex aneurysm (inner radius sac 18 mm, inner radius neck 8 mm), equipped with 12 tantalum markers, was attached to an in vitro circulation model. Fluoroscopic roentgenographic stereo photogrammetric analysis (FRSA) was used to measure marker movement during six cardiac cycles. The radius of three circles drawn through the markers was measured before and after sac filling. Wall movement was measured at different systemic pressures. Wall stress was calculated from the measured radius (σ = pr/2t).ResultsThe calculated wall stress was 7.5-15.6 N/cm2 before sac filling and was diminished to 0.43-1.1 N/cm2 after sac filling. Before sac filling, there was a clear increase (P < .001) in radius of the proximal (range, 7.9%-33.5%), middle (range, 3.3%-25.2%), and distal (range, 10.5%-184.3%) rings with increasing systemic pressure. After sac filling with the elastomer, there remained a small, significant (P < .001) increase in the radius of the circles (ranges: 6.8%-8.8%; 0.7%-1.1%; 5.3%-6.7%). The sac filling reduced the extent of radius increase. The treated aneurysm withstood systemic pressures up to 220/140 mm Hg without noticeable wall movement. After the sac filling, there was no pulsation visible in the aneurysm wall.ConclusionsFilling the aneurysm sac of a simplified in vitro latex model with a biocompatible elastomer leads to successful exclusion of the aneurysm sac from the circulation. Wall movement and calculated wall stress are diminished noticeably by the injection of biocompatible elastomer.Clinical RelevanceFilling the aneurysm sac with an elastomer has a lot of potential advantages, compared with the current endovascular treatment options. To fill the sac with the biocompatible elastomer, only a fill catheter with diameter of minimal 7 F and endovascular balloons need to be introduced transfemorally to the aneurysm sac. Most stent grafts need a minimal diameter of 14 F-22 F for access to the bulky delivery sheath, which makes many aneurysms with strong tortuosity or occlusive disease of the iliac arteries ineligible for treatment. In theory, any abdominal aortic aneurysm with a deviant anatomy will become treatable, as endovascular balloons will be available in different kinds of shape and configurations. As stated above, future research must take place before this treatment option can be applied in vivo. Animal experiments will take place to prevent embolic complications during the filling process and to investigate the short- and long-term effects of the presence of the elastomer in the aorta. Research on this novel treatment concept is in full progress and will be reported in the near future