35 research outputs found

    Prevalence of Hearing Loss in Dutch Newborns: Results of the Nationwide Well-Baby Newborn Hearing Screening Program

    Get PDF
    Background: Few studies report prevalence rates of hearing loss in newborns for nationwide populations. The Dutch well-baby newborn hearing screening covers almost all eligible children and has high participation rates for follow-up screening rounds and diagnosis. This allows calculating reliable prevalence rates of permanent neonatal hearing loss specified by severity. Methods: Results from the well-baby newborn hearing screening program and diagnostic follow-up of referred children from 2015 to 2019 were included in calculating prevalence rates. Hearing loss was classified according to the degree of severity. Results: A total of 99.7% of 833,318 children eligible for screening were included. A total of 0.3% were referred for audiological diagnostics. Permanent bilateral hearing loss of ≥40 dB was diagnosed in 23.7% of them and unilateral hearing loss in 14.4%. A prevalence rate of 1.23 per 1000 children was found, 0.46 for unilateral hearing loss and 0.76 for bilateral hearing loss. Moderate hearing loss is most common in children with bilateral hearing loss (0.47), followed by profound (0.21) and severe (0.06) hearing loss. In children with unilateral hearing loss, prevalence rates are the highest for profound hearing loss (0.21), followed by moderate (0.16) and severe (0.09) hearing loss. A total of 87.5% of the children were diagnosed within the age of 3 months. Conclusions: Because of the high quality of the Dutch well-baby hearing screening program, reported results approximate true prevalence rates of permanent hearing loss by severity

    Economic evaluation of different screening strategies for severe combined immunodeficiency based on real-life data

    Get PDF
    Although several countries have adopted severe combined immunodeficiency (SCID) into their newborn screening (NBS) program, other countries are still in the decision process of adding this disorder in their program and finding the appropriate screening strategy. This decision may be influenced by the cost(-effectiveness) of these screening strategies. In this study, the cost(-effectiveness) of different NBS strategies for SCID was estimated based on real-life data from a prospective implementation study in the Netherlands. The cost of testing per child for SCID was estimated at EUR 6.36. The cost of diagnostics after screen-positive results was assessed to vary between EUR 985 and 8561 per child dependent on final diagnosis. Cost-effectiveness ratios varied from EUR 41,300 per QALY for the screening strategy with T-cell receptor excision circle (TREC) <= 6 copies/punch to EUR 44,100 for the screening strategy with a cut-off value of TREC <= 10 copies/punch. The analysis based on real-life data resulted in higher costs, and consequently in less favorable cost-effectiveness estimates than analyses based on hypothetical data, indicating the need for verifying model assumptions with real-life data. The comparison of different screening strategies suggest that strategies with a lower number of referrals, e.g., by distinguishing between urgent and less urgent referrals, are favorable from an economic perspective.Analysis and support of clinical decision makin

    Adolescents and MP3 Players: Too Many Risks, Too Few Precautions

    Get PDF
    OBJECTIVE. The goal was to assess risky and protective listening behaviors of adolescent users of MP3 players and the association of these behaviors with demographic characteristics and frequency of use. METHODS. In 2007, 1687 adolescents (12–19 years of age) in 68 classes in 15 Dutch secondary schools were invited to complete questionnaires about their music-listening behaviors. RESULTS. Ninety percent of participants reported listening to music through earphones on MP3 players; 32.8% were frequent users, 48.0% used high volume settings, and only 6.8% always or nearly always used a noise-limiter. Frequent users were _4 times more likely to listen to high-volume music than were infrequent users, and adolescents in practical prevocational schools were more than twice as likely to listen to high-volume music as were those attending preuniversity education. CONCLUSIONS. When using MP3 players, adolescents are very likely to engage in risky listening behaviors and are unlikely to seek protection. Frequent MP3 player use is an indicator of other risky listening behaviors, such as listening at high volumes and failing to use noise-limiter

    Costs and effects of conventional vision screening and photoscreening in the Dutch preventive child health care system

    Get PDF
    Background: Little is known about costs and effects of vision screening strategies to detect amblyopia. Aim of this study was to compare costs and effects of conventional (optotype) vision screening, photoscreening or a combination in children aged 3-6 years. Methods: Population-based, cross-sectional study in preventive child health care in The Hague. Children aged 3 years (3y), 3 years and 9 months (3y9m) or 5-6 years (5/6y) received the conventional chart vision screening and a test with a photoscreener (Plusoptix 512C). Costs were based on test duration and additional costs for devices and diagnostic work-up. Results: Two thousand, one hundred and forty-four children were included. The estimated costs per child screened were (sic)17.44, (sic)20.37 and (sic)6.90 for conventional vision screening at 3y, 3y9m and 5/6y, respectively. For photoscreening, these estimates were (sic)6.61, (sic)7.52 and (sic)9.40 and for photoscreening followed by vision screening if the result was unclear (combination) (sic)9.32 (3y) and (sic)9.33 (3y9m). The number of children detected with amblyopia by age were 9, 14 and 5 (conventional screening), 6, 13 and 3 (photoscreening) and 10 (3y) and 15 (3y9m) (combination), respectively. The estimated costs per child diagnosed with amblyopia were (sic)1500, (sic)1050 and (sic)860 for conventional vision screening, (sic)860, (sic)420 and (sic)1940 for photoscreensic)ing and (sic)730 (3y) and (sic)450 (3y9m) for the combination. Conclusions: Combining photoscreening with vision screening seems promising to detect amblyopia in children aged 3y/3y9m, whereas conventional screening seems preferable at 5/6y. As the number of study children with amblyopia is small, further research on the effects of these screening alternatives in detecting children with amblyopia is recommended.Research into fetal development and medicin

    Minimale gegevensset PSIE

    No full text

    Intramyocardial blood volume and oxygen exchange

    No full text
    Mechanical Maritime and Materials Engineerin

    Indicatoren en gegevensset voor het Nationaal Programma Grieppreventie

    No full text

    Indicatoren en gegevensset voor de neonatale gehoorscreening door de jeugdgezondheidszorg

    No full text
    corecore