9 research outputs found

    One-Step Reverse Osmosis Based on Riverbank Filtration for Future Drinking Water Purification

    Get PDF
    The presence of newly emerging pollutants in the aquatic environment poses great challenges for drinking water treatment plants. Due to their low concentrations and unknown characteristics, emerging pollutants cannot be efficiently removed by conventional water treatment processes, making technically, economically, and environmentally friendly water purification technologies increasingly important. This article introduces a one-step reverse osmosis (OSRO) concept consisting of riverbank filtration (RBF) and reverse osmosis (RO) for drinking water treatment. The OSRO concept combines the relatively low-cost natural pretreatment of river water with an advanced engineered purification system. RBF provides a continuous natural source of water with stable water quality and a robust barrier for contaminants. With the pre-removal of particles, organic matter, organic micro-pollutants (OMPs), and microbes, RBF becomes an ideal source for a purification system based on RO membranes, in comparison with the direct intake of surface water. OSRO treatment removes almost 99.9% of the particles, pathogens, viruses, and OMPs, as well as the vast majority of nutrients, and thus meets the requirements for the chlorine-free delivery of drinking water with high biostability. The OSRO treatment is cost effective compared with the standard conventional series of purification steps involving sprinkling filters, softening, and activated carbon. Artificial bank filtration (ABF), which functions as an artificial recharge in combination with a sand filtration system, is proposed as an alternative for RBF in the OSRO concept to supply drinking water from locally available resources. It is also suggested that the OSRO concept be implemented with wind power as an alternative energy source in order to be more sustainable and renewable. An OSRO-based decentralized water system is proposed for water reclaiming and reuse. It is suggested that future water treatment focus on the combination of natural and engineered systems to provide drinking water through technically efficient, financially feasible, resource reusable, and environmentally relevant means.Sanitary Engineerin

    Capturing and tracing the spatiotemporal variations of planktonic and particle-associated bacteria in an unchlorinated drinking water distribution system

    Get PDF
    The aperiodic changes in the quantity and community of planktonic and particle-associated bacteria have hampered the understanding and management of microbiological water quality in drinking water distribution systems. In this study, online sampling was combined with the microbial fingerprint-based SourceTracker2 to capture and trace the spatiotemporal variations in planktonic and particle-associated bacteria in an unchlorinated distribution system. The results showed that spatially, the particle load significantly increased, while in contrast, the quantity of particle-associated bacteria decreased sharply from the treatment plant to the distribution network. Similar to the trend of particle-associated bacterial diversity, the number of observed OTUs first slightly decreased from the treatment plant to the transportation network and then sharply increased from the transportation network to the distribution network. The SourceTracker2 results revealed that the contribution of particle-associated bacteria from the treatment plant decreased along the distribution distance. The spatial results indicate the dominant role of sedimentation of particles from the treatment plant, while the observed increases in particles and the associated bacteria mainly originated from the distribution network, which were confirmed directly by the increased contributions of loose deposits and biofilm. Temporally, the daily peaks of particle-associated bacterial quantity, observed OTU number, and contributions of loose deposits and biofilms were captured during water demand peaks (e.g., 18–21 h). The temporal results reveal clear linkages between the distribution system harboring bacteria (e.g., within loose deposits and biofilms) and the planktonic and particle-associated bacteria flowing through the distribution system, which are dynamically connected and interact. This study highlights that the spatiotemporal variations in planktonic and particle-associated bacteria are valuable and unneglectable for the widely on-going sampling campaigns required by water quality regulations and/or drinking water microbiological studies.Sanitary Engineerin

    Microbial community assembly and metabolic function in top layers of slow sand filters for drinking water production

    Get PDF
    Slow sand filters (SSFs) are widely applied to treat potable water; the removal of contaminants (e.g., particles, organic matter, and microorganism) occurs primarily in the top layer. However, the development of the microbial community and its metabolic function is still poorly understood. In the present study, we analyzed the microbial quantity and community of the influents sampled from the effluent of the last step (rapid sand filtration) and of the top layers of SSFs (Schmutzdecke, 0–2 cm, 4–6 cm, 8–10 cm) sampled near terminal head loss when the Schmutzdecke (SCM) was most developed in two full-scale drinking water treatment plants (DWTPs). The two DWTPs use the same artificially recharged groundwater source. The biomass in the filter, quantified by flow cytometric intact cell counts (ICC) and adenosine triphosphate (ATP), decreased rapidly along the depth till 8–10 cm (>1 log TCC; >75% ATP); the decrease was most pronounced from the SCM to the surface sand layer (0–2 cm), after which the biomass stabilized quickly at lower depths (2–10 cm). Remarkably, beta diversity showed that SSFs layers of the same depth in two DWTPs with distinctive filter age and plant location clustered together, which indicated their insignificant effects in shaping microbial communities in SSFs. The alpha diversity indices followed the trend of the biomass, suggesting more active and diverse communities in SCM layer. PICRUSt-based function prediction revealed significant over-representation of metabolism and degradation of complex organic matters (e.g., butanoate, propanoate, xenobiotic, D-Alanine, chloroalkene, and bisphenol) in SCM layer, the functional importance of which was confirmed by the co-occurrence patterns of the dominant taxa and metabolic functions. Using an island biogeography model, we found that microbial communities in SSFs were strongly assembled by selection (68 OTUs, 50.0% sequences), rather than by simple accumulation of the microbial communities in the influents (120 OTUs, 44.8% sequences). Our findings enhance the understanding of microbial community assembly and of metabolic function in the top layers of SSFs, and constitute a valuable contribution to optimizing the design and operation of biofilters in full-scale DWTPs.Sanitary EngineeringBT/Environmental Biotechnolog

    Effectiveness of antiscalants in preventing calcium phosphate scaling in reverse osmosis applications

    Get PDF
    Antiscalants are well known to prevent the precipitation of carbonate and sulphate scales of calcium in reverse osmosis (RO) applications, but according to literature their inhibitory ability against calcium phosphate is not clear. The objective of this study was to investigate if antiscalants, without acid addition, can prevent calcium phosphate scaling in RO systems. Eight calcium phosphate antiscalants from different manufacturers spanning a range of concentrations were tested in batch (in glass reactors) experiments to inhibit the formation of calcium phosphate in synthetic concentrate corresponding to 85% recovery (Ca2+ = 765 mg/L, PO43− = 13–15 mg/L and pH = 7.6) of a groundwater RO in the Netherlands. Additionally, once-through lab-scale RO tests were conducted where an RO element was fed with synthetic concentrate and the performance of antiscalants was evaluated from the rate of flux-decline in the RO element. Without antiscalant addition, a substantial flux-decline was observed due to the deposition of amorphous calcium phosphate (ACP) on the RO membrane. The tested antiscalants were unable to inhibit the formation of ACP and were incapable of preventing the deposition of the formed ACP particles, since with each antiscalant, the flux of the RO element decreased at least 15% in a 3-h period. Briefly, the available antiscalants, tested in this study, did not provide acceptable inhibition of calcium phosphate scaling in RO applications.Sanitary Engineerin

    Role of phosphate and humic substances in controlling calcium carbonate scaling in a groundwater reverse osmosis system

    Get PDF
    The role of phosphate and humic substances (HS) in preventing calcium carbonate scaling and their impact on antiscalant dose was investigated for a reverse osmosis (RO) system treating anaerobic groundwater (GW) (containing 2.1 mg/L orthophosphate and 6-8 mg/L HS). Experiments were conducted with the RO unit (treating anaerobic GW), and with a once-through lab-scale RO system (operating with artificial feedwater). Additionally, (batch) induction time (IT) measurements were performed with, i) real RO concentrate, and ii) artificial RO concentrates in the presence and absence of phosphate and HS. It was found that at 80% recovery (Langelier saturation index (LSI) 1.7), calcium carbonate scaling did not occur in the RO unit when the antiscalant dose was lowered from 2.2 mg/L (supplier's recommended dose) to 0 mg/L. The IT of the real RO concentrate, without antiscalant, was longer than 168 h, while, at the same supersaturation level, the IT of the artificial concentrate was approximately 1 h. The IT of the artificial concentrate increased to 168 h with the addition of 10 mg/L of phosphate, humic acid (HA), and fulvic acid (FA). Furthermore, in the lab-scale RO tests, the normalized permeability (Kw) of the membrane decreased by 20% in 2 h period when fed with artificial concentrate of 80% recovery containing no phosphate, whereas, with phosphate, no decrease in Kw was observed in 10 h period. These results indicate that phosphate and HS present in the GW prevented calcium carbonate scaling in the RO unit and reduced the use of commercial (synthetic) antiscalants. Sanitary Engineerin

    Building water quality deterioration during water supply restoration after interruption: Influences of premise plumbing configuration

    No full text
    Premise plumbing plays an essential role in determining the final quality of drinking water consumed by customers. However, little is known about the influences of plumbing configuration on water quality changes. This study selected parallel premise plumbing in the same building with different configurations, i.e., laboratory and toilet plumbing. Water quality deteriorations induced by premise plumbing under regular and interrupted water supply were investigated. The results showed that most of the water quality parameters did not vary under regular supply, except Zn, which was significantly increased by laboratory plumbing (78.2 to 260.7 µg/l). For the bacterial community, the Chao1 index was significantly increased by both plumbing types to a similar level (52 to 104). Laboratory plumbing significantly changed the bacterial community, but toilet plumbing did not. Remarkably, water supply interruption/restoration led to serious water quality deterioration in both plumbing types but resulted in different changes. Physiochemically, discoloration was observed only in laboratory plumbing, along with sharp increases in Mn and Zn. Microbiologically, the increase in ATP was sharper in toilet plumbing than in laboratory plumbing. Some opportunistic pathogen-containing genera, e.g., Legionella spp. and Pseudomonas spp., were present in both plumbing types but only in disturbed samples. This study highlighted the esthetic, chemical, and microbiological risks associated with premise plumbing, for which system configuration plays an important role. Attention should be given to optimizing premise plumbing design for managing building water quality.Sanitary Engineerin

    Comparing the bacterial growth potential of ultra-low nutrient drinking water assessed by growth tests based on flow cytometric intact cell count versus adenosine triphosphate

    Get PDF
    The bacterial growth potential (BGP) of drinking water is widely assessed either by flow cytometric intact cell count (BGPICC) or adenosine triphosphate (BGPATP) based methods. Combining BGPICC and BGPATP measurements has been previously applied for various types of drinking water having high to low growth potential. However, this has not been applied for water with ultra-low nutrient content, such as remineralised RO permeate. To conduct a sound comparison, conventionally treated drinking water was included in this study, which was also used as an inoculum source. BGPICC, BGPATP, intact cell-yield (YICC), and ATP-yield (YATP) were determined for conventionally treated drinking water (Tap-water) and remineralised RO permeate (RO-water). In addition, both BGPICC and BGPATP methods were used to identify the growth-limiting nutrient in each water type. The results showed that the BGPICC ratio between Tap-water/RO-water was ∼7.5, whereas the BGPATP ratio was only ∼4.5. Moreover, the YICC ratio between Tap-water/RO-water was ∼2 (9.8 ± 0.6 × 106 vs. 4.6 ± 0.8 × 106 cells/µg-C), whereas the YATP ratio was ∼1 (0.39 ± 0.12 vs. 0.42 ± 0.06 ng ATP/µg-C), resulting in a consistently higher ATP per cell in RO-water than that of Tap-water. Both BGPICC and BGPATP methods revealed that carbon was the growth-limiting nutrient in the two types of water. However, with the addition of extra carbon, phosphate limitation was detected only with the BGPICC method, whereas BGPATP was not affected, suggesting that a combination of carbon and phosphate is essential for biomass synthesis, whereas carbon is probably utilised for cellular activities other than cell synthesis when phosphate is limited. It was estimated that the intact cell-yield growing on phosphate would be 0.70 ± 0.05 × 109 cells/µg PO4-P.Sanitary Engineerin

    Application of a smart dosing pump algorithm in identifying real-time optimum dose of antiscalant in reverse osmosis systems

    Get PDF
    The potential of membrane scaling control by a real-time optimization algorithm was investigated. The effect of antiscalant dosing was evaluated from the induction time measured in glass batch-reactors, and from the operational performance of a lab-scale reverse osmosis (RO) unit and two pilot-scale RO units. Step changes in the antiscalant dosing demonstrated that the accumulation of scaling is ‘paused’ during periods when the optimum dose is applied. This is paramount for the application of a dynamic dosing strategy that may briefly underdose, while searching for the optimum dose. It was found that antiscalant underdose and overdose were both detrimental to RO operation since underdose resulted in membrane scaling, while overdose led to membrane fouling due to calcium-antiscalant deposits. The dosing algorithm was used to minimize antiscalant consumption in two pilot RO units. The algorithm was able to lower the antiscalant doses to 0.2 mg/L and 0.6 mg/L, while the supplier's recommended antiscalant doses were 2.0 mg/L and 4.5 mg/L, respectively. As a result, the algorithm could reduce antiscalant consumption by up to 85–90% for the plants mentioned.Sanitary Engineerin

    Foulant Identification and Performance Evaluation of Antiscalants in Increasing the Recovery of a Reverse Osmosis System Treating Anaerobic Groundwater

    Get PDF
    The objectives of this study are to assess the performance of antiscalants in increasing the recovery (≥85%) of a reverse osmosis (RO) plant treating anaerobic groundwater (GW) in Kamerik (the Netherlands), and to identify scalants/foulant that may limit RO recovery. Five different commercially available antiscalants were compared on the basis of their manufacturer-recommended dose. Their ability to increase the recovery from 80% to a target of 85% was evaluated in pilot-scale measurements with anaerobic GW and in once-through lab-scale RO tests with synthetic (artificial) feedwater. A membrane autopsy was performed on the tail element(s) with decreased permeability. X-ray photoelectron spectroscopy (XPS) analysis indicated that calcium phosphate was the primary scalant causing permeability decline at 85% recovery and limiting RO recovery. The addition of antiscalant had no positive effect on RO operation and scaling prevention, since at 85% recovery, permeability of the last stage decreased with all five antiscalants, while no decrease in permeability was observed without the addition of antiscalant at 80% recovery. In addition, in lab-scale RO tests executed with synthetic feed water containing identical calcium and phosphate concentrations as the anaerobic GW, calcium phosphate scaling occurred both with and without antiscalant at 85% recovery, while at 80% recovery without antiscalant, calcium phosphate did not precipitate in the RO element. In brief, calcium phosphate appeared to be the main scalant limiting RO recovery, and antiscalants were unable to prevent calcium phosphate scaling or to achieve a recovery of 85% or higher.Sanitary Engineerin