4 research outputs found

    Generation of 3 spinocerebellar ataxia type 1 (SCA1) patient-derived induced pluripotent stem cell lines LUMCi002-A, B, and C and 2 unaffected sibling control induced pluripotent stem cell lines LUMCi003-A and B

    Get PDF
    Spinocerebellar ataxia type 1 (SCA1) is a hereditary neurodegenerative disease caused by a CAG repeat expansion in exon 8 of the ATXN1 gene. We generated induced pluripotent stem cells (hiPSCs) from a SCA1 patient and his non-affected sister by using non-integrating Sendai Viruses (SeV). The resulting hiPSCs are SeVfree, express pluripotency markers, display a normal karyotype, retain the mutation (length of the CAG repeat expansion in the ATXN1 gene) and are able to differentiate into the three germ layers in vitro

    Generation of 3 human induced pluripotent stem cell lines LUMCi005-A, B and C from a Hereditary Cerebral Hemorrhage with Amyloidosis-Dutch type patient

    Get PDF
    Hereditary Cerebral Hemorrhage with Amyloidosis-Dutch type (HCHWA-D) is an autosomal dominant hereditary disease caused by a point mutation in exon 17 of the APP gene. We generated human induced pluripotent stem cells (hiPSCs) from a symptomatic HCHWA-D patient by using non-integrating Sendai virus (SeV). The newly generated hiPSCs express all pluripotency markers, have a normal karyotype, carry the Dutch mutation, can differentiate in the three germ layers in vitro and are SeV free

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar
    corecore