587 research outputs found
Short versus long silver nanowires: a comparison of in vivo pulmonary effects post instillation.
BackgroundSilver nanowires (Ag NWs) are increasingly being used to produce touchscreens for smart phones and computers. When applied in a thin film over a plastic substrate, Ag NWs create a transparent, highly-conductive network of fibers enabling the touch interface between consumers and their electronics. Large-scale application methods utilize techniques whereby Ag NW suspensions are deposited onto substrates via droplets. Aerosolized droplets increase risk of occupational Ag NW exposure. Currently, there are few published studies on Ag NW exposure-related health effects. Concerns have risen about the potential for greater toxicity from exposure to high-aspect ratio nanomaterials compared to their non-fibrous counterparts. This study examines whether Ag NWs of varying lengths affect biological responses and silver distribution within the lungs at different time-points.MethodsTwo different sizes of Ag NWs (2 μm [S-Ag NWs] and 20 μm [L-Ag NWs]) were tested. Male, Sprague-Dawley rats were intratracheally instilled with Ag NWs (0, 0.1, 0.5, or 1.0 mg/kg). Broncho-alveolar lavage fluid (BALF) and lung tissues were obtained at 1, 7, and 21 days post exposure for analysis of BAL total cells, cell differentials, and total protein as well as tissue pathology and silver distribution.Results and conclusionsThe two highest doses produced significant increases in BAL endpoints. At Day 1, Ag NWs increased total cells, inflammatory polymorphonuclear cells (PMNs), and total protein. PMNs persisted for both Ag NW types at Day 7, though not significantly so, and by Day 21, PMNs appeared in line with sham control values. Striking histopathological features associated with Ag NWs included 1) a strong influx of eosinophils at Days 1 and 7; and 2) formation of Langhans and foreign body giant cells at Days 7 and 21. Epithelial sloughing in the terminal bronchioles (TB) and cellular exudate in alveolar regions were also common. By Day 21, Ag NWs were primarily enclosed in granulomas or surrounded by numerous macrophages in the TB-alveolar duct junction. These findings suggest short and long Ag NWs produce pulmonary toxicity; thus, further research into exposure-related health effects and possible exposure scenarios are necessary to ensure human safety as Ag NW demand increases
Recommended from our members
Size-Dependent Deposition, Translocation, and Microglial Activation of Inhaled Silver Nanoparticles in the Rodent Nose and Brain.
BackgroundSilver nanoparticles (AgNP) are present in personal, commercial, and industrial products, which are often aerosolized. Current understanding of the deposition, translocation, and health-related impacts of AgNP inhalation is limited.ObjectivesWe determined a) the deposition and retention of inhaled Ag in the nasal cavity from nose-only exposure; b) the timing for Ag translocation to and retention/clearance in the olfactory bulb (OB); and c) whether the presence of Ag in the OB affects microglial activity.MethodsMale Sprague-Dawley rats were exposed nose-only to citrate-buffered 20- or 110-nm AgNP (C20 or C110, respectively) or citrate buffer alone for 6 hr. The nasal cavity and OB were examined for the presence of Ag and for biological responses up to 56 days post-exposure (8 weeks).ResultsThe highest nasal Ag deposition was observed on Day 0 for both AgNP sizes. Inhalation of aerosolized C20 resulted in rapid translocation of Ag to the OB and in microglial activation at Days 0, 1, and 7. In contrast, inhalation of C110 resulted in a gradual but progressive transport of Ag to and retention in the OB, with a trend for microglial activation to variably be above control.ConclusionsThe results of this study show that after rats experienced a 6-hr inhalation exposure to 20- and 110-nm AgNP at a single point in time, Ag deposition in the nose, the rate of translocation to the brain, and subsequent microglial activation in the OB differed depending on AgNP size and time since exposure. Citation: Patchin ES, Anderson DS, Silva RM, Uyeminami DL, Scott GM, Guo T, Van Winkle LS, Pinkerton KE. 2016. Size-dependent deposition, translocation, and microglial activation of inhaled silver nanoparticles in the rodent nose and brain. Environ Health Perspect 124:1870-1875; http://dx.doi.org/10.1289/EHP234
Recommended from our members
Defining and determining the significance of impacts: concepts and methods
A Comparison of Teachers Perceptions, Misconceptions, and Teaching of Students with Dyslexia
Teachers commonly work with students with dyslexia. They may not have been aware that the reason a student struggled with many academic tasks, was due to challenges with mental processing associated with the dyslexia. Dyslexia tends to be difficult to recognize. However, the commonly associated behaviors such as acting out, withdrawing, or simply trying and failing are readily noticeable. Because of the hidden nature of dyslexia, many teachers may attribute students’ lack of academic success to other easily explainable issues, such as attention deficit disorder or issues with family function. Students’ academic and potentially life-long success, could be influenced by the lack of teacher awareness or ability to recognize the executive functioning issues of students with dyslexia. Thus, there is a need for teachers at all levels to understand what dyslexia is, hold accurate conceptions of dyslexia, and know how to effectively support the learning of students with dyslexia. Given the critical role teachers play in working with students with dyslexia and the potential teachers have to support or hinder students long term success, there is warrant for examining the perceptions, attitudes, misconceptions, and practice of teachers working with students with dyslexia
Recommended from our members
Investigations into Cost Reductions of X-band Instrumentation
The prohibitive costs of commercial test equipment for making fast and accurate pulsed phase and amplitude measurements at X-Band result in decreased productivity due to shortages of shared equipment across the test laboratory. In addition, most current set-ups rely on the use of pulsed power heads which do not allow for the measurement of phase thereby limiting the flexibility of available measurements. In this paper, we investigate less expensive in-house designed instrumentation based upon commercial satellite down converters and widely available logarithmic detector amplifiers and phase detectors. The techniques are used to measure X-Band pulses with widths of 50 ns to 10's of usec. We expect a dynamic range of 30-40 dB with accuracies of better than +/- 0.1 dB and +/- 1 degree of phase. We show preliminary results of the built and tested modules. Block diagrams of the down conversion scheme, and the architecture of a multi-signal X-band RF monitor and measurement system is illustrated. Measured results, and possible modifications and upgrades are presented
Novel lanthanide-labeled metal oxide nanoparticles improve the measurement of in vivo clearance and translocation
Abstract The deposition, clearance and translocation of europium-doped gadolinium oxide nanoparticles in a mouse lung were investigated experimentally. Nanoparticles were synthesized by spray flame pyrolysis. The particle size, crystallinity and surface properties were characterized. Following instillation, the concentrations of particles in organs were determined with inductively coupled plasma mass spectrometry. The protein corona coating the nanoparticles was found to be similar to the coating on more environmentally relevant nanoparticles such as iron oxide. Measurements of the solubility of the nanoparticles in surrogates of biological fluids indicated very little propensity for dissolution, and the elemental ratio of particle constituents did not change, adding further support to the contention that intact nanoparticles were measured. The particles were intratracheally instilled into the mouse lung. After 24 hours, the target organs were harvested, acid digested and the nanoparticle mass in each organ was measured by inductively coupled plasma mass spectrometry (ICP-MS). The nanoparticles were detected in all the studied organs at low ppb levels; 59% of the particles remained in the lung. A significant amount of particles was also detected in the feces, suggesting fast clearance mechanisms. The nanoparticle system used in this work is highly suitable for quantitatively determining deposition, transport and clearance of nanoparticles from the lung, providing a quantified measure of delivered dose.</p
A twist in chiral interaction between biological helices
Using an exact solution for the pair interaction potential, we show that
long, rigid, chiral molecules with helical surface charge patterns have a
preferential interaxial angle ~((RH)^1/2)/L, where L is the length of the
molecules, R is the closest distance between their axes, and H is the helical
pitch. Estimates based on this formula suggest a solution for the puzzle of
small interaxial angles in a-helix bundles and in cholesteric phases of DNA.Comment: 7 pages, 2 figures, PDF file onl
- …