17 research outputs found

    Faecal immunochemical tests (FIT) can help to rule out colorectal cancer in patients presenting in primary care with lower abdominal symptoms:a systematic review conducted to inform new NICE DG30 diagnostic guidance

    Get PDF
    __Background:__ This study has attempted to assess the effectiveness of quantitative faecal immunochemical tests (FIT) for triage of people presenting with lower abdominal symptoms, where a referral to secondary care for investigation of suspected colorectal cancer (CRC) is being considered, particularly when the 2-week criteria are not met. __Methods:__ We conducted a systematic review following published guidelines for systematic reviews of diagnostic tests. Twenty-one resources were searched up until March 2016. Summary estimates were calculated using a bivariate model or a random-effects logistic regression model. __Results:__ Nine studies are included in this review. One additional study, included in our systematic review, was provided as 'academic in confidence' and cannot be described herein. When FIT was based on a single faecal sample and a cut-off of 10 μg Hb/g faeces, sensitivity estimates indicated that a negative result using either the OC-Sensor or HM-JACKarc may be adequate to rule out nearly all CRC; the summary estimate of sensitivity for the OC-Sensor was 92.1%, based on four studies, and the only study of HM-JACKarc to assess the 10 μg Hb/g faeces cut-off reported a sensitivity of 100%. The corresponding specificity estimates were 85.8% (95% CI 78.3-91.0%) and 76.6%, respectively. When the diagnostic criterion was changed to include lower grades of neoplasia, i.e. the target condition included higher risk adenoma (HRA) as well as CRC, the rule-out performance of both FIT assays was reduced. __Conclusions:__ There is evidence to suggest that triage using FIT at a cut-off around 10 μg Hb/g faeces has the potential to correctly rule out CRC and avoid colonoscopy in 75-80% of symptomatic patients. Systematic review registration: PROSPERO 4201603772

    Double sampling of a faecal immunochemical test is not superior to single sampling for detection of colorectal neoplasia: a colonoscopy controlled prospective cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A single sampled faecal immunochemical test (FIT) has moderate sensitivity for colorectal cancer and advanced adenomas. Repeated FIT sampling could improve test sensitivity. The aim of the present study is to determine whether any of three different strategies of double FIT sampling has a better combination of sensitivity and specificity than single FIT sampling.</p> <p>Methods</p> <p>Test performance of single FIT sampling in subjects scheduled for colonoscopy was compared to double FIT sampling intra-individually. Test positivity of double FIT sampling was evaluated in three different ways: 1) "one of two FITs+" when at least one out of two measurements exceeded the cut-off value, 2) "two of two FITs+" when both measurements exceeded the cut-off value, 3) "mean of two FITs+" when the geometric mean of two FITs exceeded the cut-off value. Receiver operator curves were calculated and sensitivity of single and the three strategies of double FIT sampling were compared at a fixed level of specificity.</p> <p>Results</p> <p>In 124 of 1096 subjects, screen relevant neoplasia (SRN) were found (i.e. early stage CRC or advanced adenomas). At any cut-off, "two of two FITs+" resulted in the lowest and "one of two FITs+" in the highest sensitivity for SRN (range 35-44% and 42%-54% respectively). ROC's of double FIT sampling were similar to single FIT sampling. At specificities of 85/90/95%, sensitivity of any double FIT sampling strategy did not differ significantly from single FIT (p-values 0.07-1).</p> <p>Conclusion</p> <p>At any cut off, "one of two FITs+" is the most sensitive double FIT sampling strategy. However, at a given specificity level, sensitivity of any double FIT sampling strategy for SRN is comparable to single FIT sampling at a different cut-off value. None of the double FIT strategies has a superior combination of sensitivity and specificity over single FIT.</p

    Findings in the Colon

    No full text

    Diversity of endoscopy center operations and practice variation across California¿s safety-net hospital system: a statewide survey

    Get PDF
    Abstract Background Little is known about endoscopic services provided or operational practice variation within California public hospital endoscopy centers. Methods A survey was distributed to all 18 California public hospitals with endoscopy centers to assess operational practices. Results Eight of 18 hospitals responded to the survey. Six of the eight responding hospitals used a closed access system for patient referrals. Mean wait time for an endoscopic procedure was 42.4 ± 37.7 days (N = 8) with a mean procedure no-show/cancellation rate of 14.5 ± 8.0% (N = 7). All responding public hospitals performed colonoscopy, esophagogastroduodenoscopy, PEG tube placement, and endoscopic retrograde cholangiopancreatography (ERCP) with two hospitals performing endoscopic ultrasound. There was significant practice variation in the documentation of endoscopic quality and performance measurements among the responding hospitals. Multiple methods were used to communicate pathology results to patients: GI clinic visit (6/8), primary physician (4/8), telephone (2/8) or letter (1/8). Conclusion Our study highlights the diversity and practice variations of endoscopy center operations at California public hospitals and serves as a catalyst for future collaborations among safety-net hospitals
    corecore