7 research outputs found

    Poor reproducibility of compression elastography in the Achilles tendon: same day and consecutive day measurements.

    Get PDF
    OBJECTIVE To determine the reproducibility of compression elastography (CE) when measuring strain data, a measure of stiffness of the human Achilles tendon in vivo, over consecutive measures, consecutive days and when using different foot positions. MATERIALS AND METHODS Eight participants (4 males, 4 females; mean age 25.5 ± 2.51 years, range 21-30 years; height 173.6 ± 11.7 cm, range 156-189 cm) had five consecutive CE measurements taken on one day and a further five CE measures taken, one per day, at the same time of day, every day for a consecutive 5-day period. These 80 measurements were used to assess both the repeatability and reproducibility of the technique. Means, standard deviations, coefficient of variation (CV), Pearson correlation analysis (R) and intra-class correlation coefficients (ICC) were calculated. RESULTS For CE data, all CVs were above 53%, R values indicated no-to-weak correlations between measures at best (range 0.01-0.25), and ICC values were all classified in the poor category (range 0.00-0.11). CVs for length and diameter measures were acceptably low indicating a high level of reliability. CONCLUSIONS Given the wide variation obtained in the CE results, it was concluded that CE using this specific system has a low level of reproducibility for measuring the stiffness of the human Achilles tendon in vivo over consecutive days, consecutive measures and in different foot positions

    Relationship between neovascularization and clinical severity in Achilles tendinopathy in 556 paired measurements

    No full text
    Neovascularization is frequently observed in tendinopathy. Previous studies have focused on the role of neovascularization in Achilles tendinopathy, but have been conducted in small series. It is still unclear whether the degree of neovascularization is related to severity of symptoms. The purpose was to study the relationship between ultrasonographic neovascularization and clinical severity in patients with Achilles tendinopathy. In this prospective cohort study, data on 127 patients (141 tendons) were assembled from databases of three clinical trials. All patients followed an eccentric exercise program. The ohberg neovascularization score (0-4+) and Victorian Institute of Sports Assessment-Achilles (VISA-A) score (split into domains: pain, function and activity) were collected during baseline and follow-up. The relationship between neovascularization and VISA-A score was calculated. At baseline, 107 tendons (76%) showed some degree of neovascularization. In 556 coupled measurements, neovascularization was weakly related to the VISA-A score [Exp (B) 1.017, 95% confidence interval (CI), 1.007-1.026]. No significant relationship was found between neovascularization and the pain domain (P=0.277) and the activity domain (P=0.283), but there was between neovascularization and the function domain of the VISA-A score [Exp (B)=1.067, 95% CI 1.018-1.119]. In conclusion, neovascularization in Achilles tendinopathy is weakly related to clinical severity, mainly based on the function domain of the VISA-A score
    corecore