119 research outputs found

    The role of optical coherence tomography and infrared oculography in assessing the visual pathway and CNS in multiple sclerosis

    Get PDF
    In this review, a current overview is provided of how optical coherence tomography and infrared oculography can aid in assessing the visual system and CNS in multiple sclerosis (MS). Both afferent and efferent visual disorders are common in MS and visual complaints can have a tremendous impact on daily functioning. Optical coherence tomography and infrared oculography can detect and quantify visual disorders with high accuracy, but could also serve as quantitative markers for inflammation, neurodegeneration and network changes including cognitive decline in MS patients. The assessment of the efferent and afferent visual pathways is relevant for monitoring and predicting the disease course, but is also potentially valuable as an outcome measure in therapeutic trials

    Is there a relationship between oculomotor fatigability and perceived fatigue in multiple sclerosis?

    Get PDF

    Quantification of Visual Fixation in Multiple Sclerosis

    Get PDF
    Purpose: Eye movement abnormalities are common in multiple sclerosis (MS), and infrared oculography is a noninvasive method for quantification. This study aims to describe and classify abnormalities of visual fixation and their clinical relevance in MS. Methods: A validated standardized infrared oculography protocol, Demonstrate Eye Movement Networks with Saccades, was used for quantifying gaze stability during a fixation task in MS patients and healthy controls. Saccadic intrusions, gaze drift, and stability of fixation around the drift line were used to subclassify MS patients by performing receiver operating characteristic analyses of different parameters. The relationship between the presence of abnormalities of fixation and visual functioning was analyzed using logistic regression models, which was adjusted for possible confounders. Results: This cross-sectional study included 213 subjects with MS and 57 healthy controls. Square wave jerk abnormalities were present in 24% of MS patients. The prevalence was higher in more disabled subjects. The presence of larger square wave jerks (with a higher amplitude) in the MS patients was related to complaints of focusing on stationary objects (odds ratio, 2.2; P = 0.035) and a lower vision-related quality of life (odds ratio, 2.56; P = 0.012). Conclusions: This study provided a comprehensive overview of the characteristics of problems with visual fixation in subjects with MS. The most important and most common finding was the presence of larger square wave jerks during fixation, which was related to visual functioning in daily life

    Saccadic fatigability in the oculomotor system

    Get PDF
    BACKGROUND: Fatigue is one of the most common and disabling symptoms in multiple sclerosis (MS), but challenging to quantify. This prospective study investigated if repeated saccadic eye movements enable measurement of oculomotor fatigability and can reflect on perceived fatigue in MS. METHODS: A standardized infrared oculography protocol (DEMoNS) was used for quantifying saccades in MS patients and healthy controls which included a first and a repeated pro-saccadic task (FPT and RPT). Saccadic peak velocity, latency, gain, area under the curve (AUC) and peak velocity divided by amplitude (Pv/Am) were calculated in both tasks. Perception based fatigue was assessed using the Checklist Individual Strength and the Neurological Fatigue Index (NFI). Linear regression models were used for assessing the relation between saccadic parameters and perceived fatigue. RESULTS: This study included 181 MS patients and 58 healthy controls subjects. From FPT to RPT, there were significant changes in saccadic parameters. Latency of both tasks was significantly related to NFI summary score (FPT: β = 0.022, p = .049, RPT: β 0.023, p = .021). These relationships were weakened after adjustment for Expanded Disability Status score (p > .05). There was however no significant group difference in changes in saccadic parameters. CONCLUSIONS: This study presents an objective and reproducible method for measuring saccadic fatigability. Saccadic fatigability was found to be of limited use in MS, and should be tested in conditions affecting ocular muscles or the neuromuscular junction

    Diagnosing and quantifying a common deficit in multiple sclerosis: Internuclear ophthalmoplegia

    Get PDF
    OBJECTIVE: We present an objective and quantitative approach for diagnosing internuclear ophthalmoplegia (INO) in multiple sclerosis (MS). METHODS: A validated standardized infrared oculography protocol (DEMoNS [Demonstrate Eye Movement Networks with Saccades]) was used for quantifying prosaccades in patients with MS and healthy controls (HCs). The versional dysconjugacy index (VDI) was calculated, which describes the ratio between the abducting and adducting eye. The VDI was determined for peak velocity, peak acceleration, peak velocity divided by amplitude, and area under the curve (AUC) of the saccadic trajectory. We calculated the diagnostic accuracy for the several VDI parameters by a receiver operating characteristic analysis comparing HCs and patients with MS. The National Eye Institute Visual Function Questionnaire-25 was used to investigate vision-related quality of life of MS patients with INO. RESULTS: Two hundred ten patients with MS and 58 HCs were included. The highest diagnostic accuracy was achieved by the VDI AUC of 15° horizontal prosaccades. Based on a combined VDI AUC and peak velocity divided by amplitude detection, the prevalence of an INO in MS calculated to 34%. In the INO group, 35.2% of the patients with MS reported any complaints of double vision, compared to 18.4% in the non-INO group (p = 0.010). MS patients with an INO had a lower overall vision-related quality of life (median 89.9, interquartile range 12.8) compared to patients without an INO (median 91.8, interquartile range 9.3, p = 0.011). CONCLUSIONS: This study provides an accurate quantitative and clinically relevant definition of an INO in MS. This infrared oculography-based INO standard will require prospective validation. The high prevalence of INO in MS provides an anatomically well described and accurately quantifiable model for treatment trials in MS

    The prevalence of internuclear ophthalmoparesis in a population-based cohort of individuals with multiple sclerosis

    Get PDF
    BACKGROUND: Internuclear ophthalmoparesis (INO) occurs in 15-52% of individuals with multiple sclerosis (MS) and is reliably detected by infrared oculography. Methods for diagnosing INO with infrared oculography and the association between INO and MS characteristics need confirmation. We aimed to describe INO prevalence and the clinical characteristics of individuals with MS and INO in a population-based cohort of individuals with MS born in the year 1966 (Project Y). METHODS: Previously described thresholds for the versional dysconjugacy index (VDI), assessed with standardized infrared oculography, were used to detect INO in participants of project Y. Clinical characteristics, visual functioning and complaints were compared between individuals with MS with INO and individuals with MS without INO. RESULTS: Two-hundred-twenty individuals with MS and 110 healthy controls were included. VDI values exceeding the threshold for INO presented in 53 (24%) individuals with MS and 19 controls (13%). INO was associated with male sex, greater disability, worse cognition and worse arm function in individuals with MS. There was no association with disease duration, visual functioning or complaints. CONCLUSIONS: INO is prevalent among individuals with MS aged fifty-three and related to clinical characteristics of MS. INO was more frequently detected in healthy controls than previous studies, implying that oculography based diagnosis of INO requires further refinement

    A standardized protocol for quantification of saccadic eye movements: DEMoNS

    Get PDF
    OBJECTIVE: Quantitative saccadic testing is a non-invasive method of evaluating the neural networks involved in the control of eye movements. The aim of this study is to provide a standardized and reproducible protocol for infrared oculography measurements of eye movements and analysis, which can be applied for various diseases in a multicenter setting. METHODS: Development of a protocol to Demonstrate Eye Movement Networks with Saccades (DEMoNS) using infrared oculography. Automated analysis methods were used to calculate parameters describing the characteristics of the saccadic eye movements. The two measurements of the subjects were compared with descriptive and reproducibility statistics. RESULTS: Infrared oculography measurements of all subjects were performed using the DEMoNS protocol and various saccadic parameters were calculated automatically from 28 subjects. Saccadic parameters such as: peak velocity, latency and saccade pair ratios showed excellent reproducibility (intra-class correlation coefficients > 0.9). Parameters describing performance of more complex tasks showed moderate to good reproducibility (intra-class correlation coefficients 0.63-0.78). CONCLUSIONS: This study provides a standardized and transparent protocol for measuring and analyzing saccadic eye movements in a multicenter setting. The DEMoNS protocol details outcome measures for treatment trial which are of excellent reproducibility. The DEMoNS protocol can be applied to the study of saccadic eye movements in various neurodegenerative and motor diseases

    A paediatric bone index derived by automated radiogrammetry

    Get PDF
    Hand radiographs are obtained routinely to determine bone age of children. This paper presents a method that determines a Paediatric Bone Index automatically from such radiographs. The Paediatric Bone Index is designed to have minimal relative standard deviation (7.5%), and the precision is determined to be 1.42%. Introduction We present a computerised method to determine bone mass of children based on hand radiographs, including a reference database for normal Caucasian children. Methods Normal Danish subjects (1,867), of ages 7-17, and 531 normal Dutch subjects of ages 5-19 were included. Historically, three different indices of bone mass have been used in radiogrammetry all based on A = pi TW(1 - T/W), where T is the cortical thickness and W the bone width. The indices are the metacarpal index A/W-2, DXR-BMD=A/W, and Exton-Smith's index A/(WL), where L is the length of the bone. These indices are compared with new indices of the form A/((WLb)-L-a), and it is argued that the preferred index has minimal SD relative to the mean value at each bone age and sex. Finally, longitudinal series of X-rays of 20 Japanese children are used to derive the precision of the measurements. Results The preferred index is A/((WL0.33)-L-1.33), which is named the Paediatric Bone Index, PBI. It has mean relative SD 7.5% and precision 1.42%. Conclusions As part of the BoneXpert method for automated bone age determination, our method facilitates retrospective research studies involving validation of the proposed index against fracture incidence and adult bone mineral densit
    • …
    corecore