51 research outputs found

    Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery?:In Vitro and In Vivo Performances

    Get PDF
    Osteosynthesis systems are used to fixate bone segments in maxillofacial surgery. Titanium osteosynthesis systems are currently the gold standard. However, the disadvantages result in symptomatic removal in up to 40% of cases. Biodegradable osteosynthesis systems, composed of degradable polymers, could reduce the need for removal of osteosynthesis systems while avoiding the aforementioned disadvantages of titanium osteosyntheses. However, disadvantages of biodegradable systems include decreased mechanical properties and possible foreign body reactions. In this review, the literature that focused on the in vitro and in vivo performances of biodegradable and titanium osteosyntheses is discussed. The focus was on factors underlying the favorable clinical outcome of osteosyntheses, including the degradation characteristics of biodegradable osteosyntheses and the host response they elicit. Furthermore, recommendations for clinical usage and future research are given. Based on the available (clinical) evidence, biodegradable copolymeric osteosyntheses are a viable alternative to titanium osteosyntheses when applied to treat maxillofacial trauma, with similar efficacy and significantly lower symptomatic osteosynthesis removal. For orthognathic surgery, biodegradable copolymeric osteosyntheses are a valid alternative to titanium osteosyntheses, but a longer operation time is needed. An osteosynthesis system composed of an amorphous copolymer, preferably using ultrasound welding with well-contoured shapes and sufficient mechanical properties, has the greatest potential as a biocompatible biodegradable copolymeric osteosynthesis system. Future research should focus on surface modifications (e.g., nanogel coatings) and novel biodegradable materials (e.g., magnesium alloys and silk) to address the disadvantages of current osteosynthesis systems

    Retreatment of multiple failing maxillary implants after full arch rehabilitation:a retrospective, observational cohort study

    Get PDF
    The aim of this study was to assess implant retreatment in a group of patients whose maxillary implants were all failing after full arch rehabilitation. Treatment involved implant removal, augmentation, and placement of an overdenture supported by four to six implants. All consecutive patients referred between 2008 and 2018, following multiple late implant failures in the rehabilitated maxilla, were included in the study. Seventy implants in 15 patients were evaluated at 3.3 +/- 2.5 years (range 1.1-8.6 years) after loading. Implant survival, complications, clinical parameters, marginal bone loss, and patient-related outcome measures were recorded at the time of evaluation. Overall implant survival was 95.7%. Three implant failures occurred within the first year of function. Marginal bone loss was 0.32 +/- 0.46 mm; pocket probing depth was 4.55 +/- 1.59 mm. Plaque, calculus, inflammation, and bleeding were hardly seen (median index score 0). Patients scored their satisfaction with their overdentures as high (mean overall score 8.7 +/- 1.2, maximum 10). Chewing soft and tough food was scored as 'good' and hard food as 'moderate'. The mean Oral Health Impact Profile score was 29.5 +/- 33.3. It can be concluded that the replacement of multiple failing implants in an edentulous maxilla after bone augmentation is a safe and predictable treatment procedure when applied as an implant-supported overdenture

    Structural similarity analysis of midfacial fractures:a feasibility study

    Get PDF
    The structural similarity index metric is used to measure the similarity between two images. The aim here was to study the feasibility of this metric to measure the structural similarity and fracture characteristics of midfacial fractures in computed tomography (CT) datasets following radiation dose reduction, iterative reconstruction (IR) and deep learning reconstruction. Zygomaticomaxillary fractures were inflicted on four human cadaver specimen and scanned with standard and low dose CT protocols. Datasets were reconstructed using varying strengths of IR and the subsequently applying the PixelShine™ deep learning algorithm as post processing. Individual small and non-dislocated fractures were selected for the data analysis. After attenuating the osseous anatomy of interest, registration was performed to superimpose the datasets and subsequently to measure by structural image quality. Changes to the fracture characteristics were measured by comparing each fracture to the mirrored contralateral anatomy. Twelve fracture locations were included in the data analysis. The most structural image quality changes occurred with radiation dose reduction (0.980036±0.011904), whilst the effects of IR strength (0.995399±0.001059) and the deep learning algorithm (0.999996±0.000002) were small. Radiation dose reduction and IR strength tended to affect the fracture characteristics. Both the structural image quality and fracture characteristics were not affected by the use of the deep learning algorithm. In conclusion, evidence is provided for the feasibility of using the structural similarity index metric for the analysis of structural image quality and fracture characteristics

    Outcome of implants placed to retain craniofacial prostheses - A retrospective cohort study with a follow-up of up to 30 years

    Get PDF
    OBJECTIVES: To retrospectively assess the treatment outcomes of endosseous implants placed to retain craniofacial prostheses. MATERIAL AND METHODS: Patients with craniofacial defects resulting from congenital disease, trauma, or oncologic treatment had implant retained prostheses placed in the mastoid, orbital, or nasal region and then assessed over a period of up to 30 years. Implant survival rates were calculated with the Kaplan-Meier method. Clinical assessments consisted of scoring skin reactions under the prosthesis and the peri-implant skin reactions. Possible risk factors for implant loss were identified. Patient satisfaction was evaluated using a 10-point VAS-scale. RESULTS: A total of 525 implants placed in 201 patients were included. The median follow up was 71 months (IQR 28-174 months). Implants placed in the mastoid and nasal region showed the highest overall implant survival rates (10-year implant survival rates of 93.7% and 92.5%, respectively), while the orbital implants had the lowest overall survival rate (84.2%). Radiotherapy was a significant risk factor for implant loss (HR 3.14, p < 0.001). No differences in implant loss were found between pre- and post-operative radiotherapy (p = 0.89). Soft tissue problems were not frequently encountered, and the patients were highly satisfied with their implant-retained prosthesis. CONCLUSION: Implants used to retain craniofacial prostheses have high survival and patient satisfaction rates and can thus be considered as a predictable treatment option. Radiation is the most important risk factor for implant loss

    Diagnostic accuracy of physical examination findings for midfacial fractures:a systematic review and meta-analysis

    Get PDF
    OBJECTIVES: To conduct a systematic review and meta-analysis to assess the diagnostic accuracy of physical examination findings and related clinical decision aids for midfacial fractures in comparison to computed tomography and cone beam computed tomography. MATERIAL AND METHODS: A systematic review was performed by searching the MEDLINE, Cochrane, EMBASE, and CINAHL databases. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Pooled sensitivity, specificity, and diagnostic odds ratios with the corresponding 95% confidence intervals were calculated for each physical examination finding and reported clinical decision aids. RESULTS: After screening 2367 records, 12 studies were included. High risk of patient selection bias was detected in three studies (25%). Additionally, high concerns regarding applicability were found for the patient selection in five studies (41.7%), and for the reference standard in eleven studies (91.7%). Of the total 42 individual physical examination findings, only 31 were suitable for a meta-analysis. High specificity and low sensitivity were found for most findings. The pooled diagnostic odds ratio ranged from 1.07 to 11.38. Clinical decision aids were reported by 8 studies, but none were constructed specifically for midfacial fractures. CONCLUSION: Based on the current available evidence, the absence of physical examination findings can successfully identify patients who do not have a midfacial fracture, but the presence of individual findings does not necessarily mean that the patient has a midfacial fracture. Although various clinical decision aids were presented, none focused on exclusively midfacial fractures. CLINICAL RELEVANCE: The diagnostic accuracy of physical examination findings can be used to diagnose a midfacial fracture so as to reduce unnecessary imaging, health care costs, and exposure to ionizing radiation

    Iterative reconstruction and deep learning algorithms for enabling low-dose computed tomography in midfacial trauma

    Get PDF
    OBJECTIVES: The objective of this study was to quantitatively assess the image quality of Advanced Modeled Iterative Reconstruction (ADMIRE) and the PixelShine (PS) deep learning algorithm for the optimization of low-dose computed tomography protocols in midfacial trauma. STUDY DESIGN: Six fresh frozen human cadaver head specimens were scanned by computed tomography using both standard and low-dose scan protocols. Three iterative reconstruction strengths were applied to reconstruct bone and soft tissue data sets and these were subsequently applied to the PS algorithm. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for each data set by using the image noise measurements of 10 consecutive image slices from a standardized region of interest template. RESULTS: The low-dose scan protocol resulted in a 61.7% decrease in the radiation dose. Radiation dose reduction significantly reduced, and iterative reconstruction and the deep learning algorithm significantly improved, the CNR for bone and soft tissue data sets. The algorithms improved image quality after substantial dose reduction. The greatest improvement in SNRs and CNRs was found using the iterative reconstruction algorithm. CONCLUSION: Both the ADMIRE and PS algorithms significantly improved image quality after substantial radiation dose reduction

    Reliability and accuracy of the torque applied to osteosynthesis screws by maxillofacial surgeons and residents

    Get PDF
    Applying the right torque to osteosynthesis screws is important for undisturbed bone healing. This study aimed to compare test-retest and intra-individual reliabilities of the torque applied to 1.5 mm and 2.0 mm osteosynthesis screws by residents and oral and maxillofacial surgeons (OMF-surgeons), to define the reference torque intervals, and to compare reference torque interval compliances. Five experienced OMF-surgeons and 20 residents, 5 of each 4 residency years, were included. Each participant inserted six 1.5 x 4 mm and six 2.0 x 6 mm screws into a preclinical model at two test moments 2 weeks apart (T1 and T2). Participants were blinded for the applied torque. Descriptive statistics, reference intervals, and intra-class correlation coefficients (ICC) were calculated. The OMF-surgeons complied more to the reference intervals (1.5 mm screws: 95% and 2.0 mm screws: 100%) than the residents (82% and 90%, respectively; P = 0.009 and P = 0.007) with the ICCs ranging between 0.85-0.95 and 0.45-0.97, respectively. The residents' accuracy and reliability were inadequate regarding the 1.5 mm screws but both measures improved at T2 for both screw types compared to T1, indicating a learning effect. Training residents and/or verifying the applied torque by experienced OMF-surgeons remains necessary to achieve high accuracy and reliability, particularly for 1.5 mm screws
    • …
    corecore