19 research outputs found

    Quantitative measurements of absorption spectra in scattering media by low-coherence spectroscopy

    Get PDF
    Low-coherence spectroscopy (LCS) is a spectroscopic method that allows for quantitative and localized assessment of absorption spectra by combining reflection spectroscopy with low-coherence interferometry. We describe absorption coefficient (µa) measurements by LCS in tissue simulating phantoms with varying scattering and absorbing properties. We used LCS in the 455–680 nm wavelength range with a spectral resolution of 8 nmto obtain µa spectra with ±0.5 mm−1 accuracy. We conclude that LCS is a promising technique for the in vivo determination of tissue chromophore concentrations

    Pressure and Flow Relations in the Systemic Arterial Tree Throughout Development From Newborn to Adult

    Get PDF
    Objective: Distributed models of the arterial tree allow studying the effect of physiological and pathophysiological changes in the vasculature on hemodynamics. For the adult, several models exist; however, a model encompassing the full age range from newborn to adult was until now lacking. Our goal is to describe a complete distributed hemodynamic model for normal development from newborn to adult. Methods: The arterial system was modeled by 121 segments characterized by length, radius, wall thickness, wall stiffness, and wall viscosity. The final segments ended in three-element Windkessels. All parameters were adapted based on body height and weight as a function of age as described in the literature. Results: Pressures and flows are calculated as a function of age at sites along the arterial tree. Central to peripheral transfer functions are given. Our results indicate that peripheral pressure in younger children resembles central pressure. Furthermore, total arterial compliance, inertance and impedance are calculated. Findings indicate that the arterial tree can be simulated by using a three-element Windkessel system. Pulse wave velocity in the aorta was found to increase during development. Conclusions: The arterial system, modeled from newborn to adult bears clinical significance, both for the interpretation of peripheral measured pressure in younger and older children, and for using a Windkessel model to determine flow from pressure measurements

    Acardius anceps with neck cyst and cleft palate : Three dimensional skeletal computed tomography reconstruction with discussion of the literature

    No full text
    Acardiac twinning is a rare anomaly of monochorionic twin pregnancies. Acardiac fetuses lack a functional heart but are passively perfused by arterial blood from their pump co-twin causing the acardiac body to be hypoxemic. In this report, we present an acardius anceps, therapeutically laser separated from its pump twin at 16 weeks. The healthy pump twin and macerated acardiac body were born at 40 3/7 weeks. A three dimensional (3D) reconstruction was made by CT images, showing cranial bones, spinal column, pelvis and lower extremities but absent arms. A cyst in the neck of the acardiac twin was identified by postnatal sonography; this was also described in four literature cases, and was additionally observed by us in two other acardiac twins. Median cleft palate was identified by oral cavity inspection but undetectable in the reconstruction. In the literature, we found 21 other acardiac anceps twins with a cleft palate. From the two larger published series, with 12 clefts in 21 acardiac anceps twins, a cleft palate occurs in over 50% during acardiac twinning. Our first hypothesis is that acardiac fetuses develop an oral cleft palate when acardiac onset starts prior to 11 weeks, because 11 weeks includes the period of embryonic oral cavity formation, and no cleft occurs when onset starts later than 11 weeks. Our second hypothesis is that cysts and cleft palates are more common in acardiac twins than currently known, likely reflecting that acardiac bodies are hypoxemic and that hypoxia contributes to the development of both cysts and clefts

    Why does second trimester demise of a monochorionic twin not result in acardiac twinning?

    Get PDF
    Background: We previously explained why acardiac twinning occurs in the first trimester. We raised the question why a sudden demised monochorionic twin beyond the first trimester does not lead to acardiac twinning. We argued that exsanguinated blood from the live twin would strongly increase the demised twins' vascular resistance, preventing its perfusion and acardiac onset. However, our current hypothesis is that perfusion of the demised twin does occur but that it is insufficient for onset of acardiac twinning. Methods: We analyzed blood pressures and flows in a vascular resistance model of a monochorionic twin pregnancy where one of the fetuses demised. The resistance model consists of a demised twin with a (former) placenta, a live twin and its placenta, and arterioarterial (AA) and venovenous placental anastomoses. We assumed that only twins with a weight of at least 33% of normal survived the first trimester and that exsanguination of more than 50% of its blood volume is fatal for the live twin. Results: At 20 weeks, only AA anastomoses with radii ≲1 mm keep the exsanguinated blood volume below 50%. Then, perfusion of the deceased body with arterial blood from the live fetus is about 5–40 times smaller than when that body was alive. Beyond 20 weeks, this factor is even smaller. At 14 weeks, this factor is at most 2. Conclusion: We hypothesize that this small perfusion flow of arterial blood prevents further growth of the deceased body and hence precludes onset of acardiac twinning

    Oxygen saturation-dependent absorption and scattering of blood

    Get PDF
    We report on the scattering properties of oxygenated and deoxygenated whole blood from 250 to 1000 nm. We determine the complex refractive index of oxygenated and deoxygenated hemoglobin using a Kramers-Kronig analysis and optical coherence tomography measurements. Combining these data with Mie theory, the scattering properties are calculated. The strong oxygen saturation dependent scattering effects should be taken into account in the data analysis of optical oxymetry
    corecore