244 research outputs found

    Current Accuracy of Augmented Reality Neuronavigation Systems: Systematic Review and Meta-Analysis

    Full text link
    BACKGROUND Augmented reality neuronavigation (ARN) systems can overlay three-dimensional anatomy and pathology without the need for a two-dimensional external monitor. Accuracy is crucial for their clinical applicability. We performed a systematic review regarding the reported accuracy of ARN systems and compared them with the accuracy of conventional infrared neuronavigation (CIN). OBJECTIVE Explore the current navigation accuracy of ARN systems and compare them with CIN. METHODS Pubmed and Embase were searched for ARN and CIN systems. For ARN: type of system, method of patient-to-image registration, accuracy method and accuracy of the system was noted. For CIN: navigation accuracy, expressed as target registration error (TRE), was noted. A meta-analysis was performed comparing the TRE of ARN and CIN systems. RESULTS 35 studies were included, 12 for ARN and 23 for CIN. ARN systems were divided into head-mounted display and heads-up display. In ARN, four methods were encountered for patient-to-image registration, of which point-pair matching was the one most frequently used. Five methods for assessing accuracy were described. 94 TRE measurements of ARN systems were compared with 9058 TRE measurements of CIN systems. Mean TRE was 2.5 mm (CI 95% 0.7 - 4.4) for ARN systems and 2.6 mm (CI 95% 2.1 - 3.1) for CIN systems. CONCLUSIONS In ARN, there seems to be lack of agreement regarding the best method to assess accuracy. Nevertheless, ARN systems seem able to achieve an accuracy comparable with CIN systems. Future studies should be prospective and compare TREs which should be measured in a standardized fashion

    Comparing the influence of mixed reality, a 3D viewer, and MRI on the spatial understanding of brain tumours

    Get PDF
    Background: Multiple 3D visualization techniques are available that obviates the need for the surgeon to mentally transform the 2D planes from MRI to the 3D anatomy of the patient. We assessed the spatial understanding of a brain tumour when visualized with MRI, 3D models on a monitor or 3D models in mixed reality.Methods: Medical students, neurosurgical residents and neurosurgeons were divided into three groups based on the imaging modality used for preparation: MRI, 3D viewer and mixed reality. After preparation, the participants needed to position, scale, and rotate a virtual tumour inside a virtual head of the patient in the same orientation as the original tumour would be. Primary outcome was the amount of overlap between the placed tumour and the original tumour to evaluate accuracy. Secondary outcomes were the position, volume and rotation deviation compared to the original tumour.Results: A total of 12 medical students, 12 neurosurgical residents, and 12 neurosurgeons were included. For medical students, the mean amount of overlap for the MRI, 3D viewer and mixed reality group was 0.26 (0.22), 0.38 (0.20) and 0.48 (0.20) respectively. For residents 0.45 (0.23), 0.45 (0.19) and 0.68 (0.11) and for neurosurgeons 0.39 (0.20), 0.50 (0.27) and 0.67 (0.14). The amount of overlap for mixed reality was significantly higher on all expertise levels compared to MRI and on resident and neurosurgeon level also compared to the 3D viewer. Furthermore, mixed reality showed the lowest deviations in position, volume and rotation on all expertise levels.Conclusion: Mixed reality enhances the spatial understanding of brain tumours compared to MRI and 3D models on a monitor. The preoperative use of mixed reality may therefore support the surgeon to improve spatial 3D related surgical tasks such as patient positioning and planning surgical trajectories

    autoTICI: Automatic Brain Tissue Reperfusion Scoring on 2D DSA Images of Acute Ischemic Stroke Patients

    Get PDF
    The Thrombolysis in Cerebral Infarction (TICI) score is an important metric for reperfusion therapy assessment in acute ischemic stroke. It is commonly used as a technical outcome measure after endovascular treatment (EVT). Existing TICI scores are defined in coarse ordinal grades based on visual inspection, leading to inter- and intra-observer variation. In this work, we present autoTICI, an automatic and quantitative TICI scoring method. First, each digital subtraction angiography (DSA) sequence is separated into four phases (non-contrast, arterial, parenchymal and venous phase) using a multi-path convolutional neural network (CNN), which exploits spatio-temporal features. The network also incorporates sequence level label dependencies in the form of a state-transition matrix. Next, a minimum intensity map (MINIP) is computed using the motion corrected arterial and parenchymal frames. On the MINIP image, vessel, perfusion and background pixels are segmented. Finally, we quantify the autoTICI score as the ratio of reperfused pixels after EVT. On a routinely acquired multi-center dataset, the proposed autoTICI shows good correlation with the extended TICI (eTICI) reference with an average area under the curve (AUC) score of 0.81. The AUC score is 0.90 with respect to the dichotomized eTICI. In terms of clinical outcome prediction, we demonstrate that autoTICI is overall comparable to eTICI.Comment: 10 pages; submitted to IEEE TM

    Effect of first pass reperfusion on outcome in patients with posterior circulation ischemic stroke

    Get PDF
    BACKGROUND: First pass reperfusion (FPR), that is, excellent reperfusion (expanded treatment in cerebral ischemia (eTICI) 2C-3) in one pass, after endovascular treatment (EVT) of an occluded artery in the anterior circulation, is associated with favorable clinical outcome, even when compared with multiple pass excellent reperfusion (MPR). In patients with posterior circulation ischemic stroke (PCS), the same association is expected, but currently unknown. We aimed to assess characteristics associated with FPR and the influence of FPR versus MPR on outcomes in patients with PCS. METHODS: We used data from the MR CLEAN Registry, a prospective observational study. The effect of FPR on 24-hour National Institutes of Health Stroke Scale (NIHSS) score, as percentage reduction, and on modified Rankin Scale (mRS) scores at 3 months, was tested with linear and ordinal logistic regression models. RESULTS: Of 224 patients with PCS, 45 patients had FPR, 47 had MPR, and 90 had no excellent reperfusion (eTICI <2C). We did not find an association between any of the patient, imaging, or treatment characteristics and FPR. FPR was associated with better NIHSS (-45% (95% CI: -65% to -12%)) and better mRS scores (adjusted common odds ratio (acOR): 2.16 (95% CI: 1.23 to 3.79)) compared with no FPR. Outcomes after FPR were also more favorable compared with MPR, but the effect was smaller and not statistically significant (NIHSS: -14% (95% CI: -51% to 49%), mRS acOR: 1.50 (95% CI: 0.75 to 3.00)). CONCLUSIONS: FPR in patients with PCS is associated with favorable clinical outcome in comparison with no FPR. In comparison with MPR, the effect of FPR was no longer statistically significant. Nevertheless, our data support the notion that FPR should be the treatment target to pursue in every patient treated with EVT

    Determinants of Symptomatic Intracranial Hemorrhage After Endovascular Stroke Treatment:A Retrospective Cohort Study

    Get PDF
    Background: Symptomatic intracranial hemorrhage (sICH) is a serious complication after endovascular treatment for ischemic stroke. We aimed to identify determinants of its occurrence and location. Methods: We retrospectively analyzed data from the Dutch MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) and MR CLEAN registry. We included adult patients with a large vessel occlusion in the anterior circulation who underwent endovascular treatment within 6.5 hours of stroke onset. We used univariable and multivariable logistic regression analyses to identify determinants of overall sICH occurrence, sICH within infarcted brain tissue, and sICH outside infarcted brain tissue. Results: SICH occurred in 203 (6%) of 3313 included patients and was located within infarcted brain tissue in 50 (25%), outside infarcted brain tissue in 23 (11%), and both within and outside infarcted brain tissue in 116 (57%) patients. In 14 patients (7%), data on location were missing. Prior antiplatelet use, baseline systolic blood pressure, baseline plasma glucose levels, post-endovascular treatment modified treatment in cerebral ischemia score, and duration of procedure were associated with all outcome parameters. In addition, determinants of sICH within infarcted brain tissue included history of myocardial infarction (adjusted odds ratio, 1.65 [95% CI, 1.06-2.56]) and poor collateral score (adjusted odds ratio, 1.42 [95% CI, 1.02-1.95]), whereas determinants of sICH outside infarcted brain tissue included level of occlusion on computed tomography angiography (internal carotid artery or internal carotid artery terminus compared with M1: adjusted odds ratio, 1.79 [95% CI, 1.16-2.78]). Conclusions: Several factors, some potentially modifiable, are associated with sICH occurrence. Further studies should investigate whether modification of baseline systolic blood pressure or plasma glucose level could reduce the risk of sICH. In addition, determinants differ per location of sICH, supporting the hypothesis of varying underlying mechanisms. Registration: URL: https://www.isrctn.com/; Unique identifier: ISRCTN10888758

    Radiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study

    Get PDF
    Background To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). Methods Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced dose and reconstructed with filtered back projection (FBP) and IR. Objective image quality in terms of noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as subjective image quality were evaluated. Results Noise, SNR and CNR were improved with IR at routine and 52% reduced dose, compared to FBP at routine dose. The lowest dose level resulted in decreased objective image quality with both FBP and IR. Subjective image quality was excellent at all dose levels. Conclusion IR resulted in improved objective image quality at routine dose and 52% reduced dose, while objective image quality deteriorated at 81% reduced dose. Subjective image quality was not affected by dose reduction

    Changes in vitamin-D metabolites and parathyroid hormone in plasma following cholecalciferol administration to pre- and postmenopausal women in the Netherlands in early spring and to postmenopausal women in Curacao

    Get PDF
    To study the effect on plasma 25-hydroxycholecalciferol (25(OH)D), 1, 25-dihydroxycholecalciferol (1, 25(OH)(2)D) and parathyroid hormone (PTH) we supplemented premenopausal (aged 30 (so 7) years) and postmenopausal (aged 61 (so 2) years) white women living in The Netherlands in late winter/early spring, and elderly black and white women (aged 75 (so 6) years) living in Curacao (Dutch Antilles) with either 10 or 20 mu g cholecalciferol/d for 4, 5 and 9 weeks respectively, Baseline plasma 25(OH)D concentration of Dutch women was lower than that of Curacao women, Postmenopausal Dutch women had a higher PTH concentration in plasma than premenopausal Dutch and postmenopausal Curacao women, There were no differences in plasma 1,25(OH),D, Cholecalciferol administration increased 25(OH)D in all groups, 1, 25(OH),D in postmenopausal Curacao women and PTH in postmenopausal Curacao women and premenopausal Dutch women, Serum and urinary Ca and phosphate concentrations did not change, There were no response differences between 10 and 20 mu g doses, Oral cholecalciferol administration (either 10 or 20 mu g/d) to women living at northern latitudes in late winter/early spring increased 25(OH)D levels to the baseline levels of elderly people living in the tropics
    • …
    corecore