2,487 research outputs found
Empowering patients with high myopia:The significance of education
Purpose: To investigate the status of patient education among highly myopic individuals focusing on the presence, sources, content, timing of the education and impact on patients. Methods: Self-reported data were collected through an online 13-item questionnaire consisting of open and multiple-choice questions. The questionnaire was sent to 250 highly myopic members of a patient organization in the Netherlands, of whom 128 (51%) responded. Results: At least one acute event had occurred in 66% (84/128) of participants at the time of the questionnaire. Among all participants, 25% (32/128) had not received patient education regarding alarm symptoms for any of these events. Among those who had been informed, the ophthalmologist was the most frequent (57%, 73/128) source of information. Participants who visited the ophthalmologist annually were more frequently informed than participants without annual visits (53%, 26/49 versus 26%, 9/35, p = 0.002). Those not informed were more likely to have a more than 3 days patient delay (92%, 12/13). Doctors delay was also present; 26% (22/84) of the participants with alarm symptoms had to wait 2 or more days before the first appointment. Long-term consequences of myopia had been discussed with 102 participants (80%, 102/128), again with the ophthalmologist as the most frequent source (59%, 76/128). Perspectives: Many myopic individuals have not been educated about their increased risk of acute events, which can result in patient delay and serious consequences with respect to visual prognosis. These findings underscore the critical importance of integrating patient education across the entire ophthalmic care chain for myopia.</p
Low-loss singlemode PECVD silicon nitride photonic wire waveguides for 532-900 nm wavelength window fabricated within a CMOS pilot line
PECVD silicon nitride photonic wire waveguides have been fabricated in a CMOS pilot line. Both clad and unclad single mode wire waveguides were measured at lambda = 532, 780, and 900 nm, respectively. The dependence of loss on wire width, wavelength, and cladding is discussed in detail. Cladded multimode and singlemode waveguides show a loss well below 1 dB/cm in the 532-900 nm wavelength range. For singlemode unclad waveguides, losses < 1 dB/cm were achieved at lambda = 900 nm, whereas losses were measured in the range of 1-3 dB/cm for lambda = 780 and 532 nm, respectively
Characterization of PECVD Silicon Nitride Photonic Components at 532 and 900 nm Wavelength
Low temperature PECVD silicon nitride photonic waveguides have been fabricated by both electron beam lithography and 200 mm DUV lithography. Propagation losses and bend losses were both measured at 532 and 900 nm wavelength, revealing sub 1dB/cm propagation losses for cladded waveguides at both wavelengths for single mode operation. Without cladding, propagation losses were measured to be in the 1-3 dB range for 532 nm and remain below 1 dB/cm for 900 nm for single mode waveguides. Bend losses were measured for 532 nm and were well below 0.1 dB per 90 degree bend for radii larger than 10 mu m
Gastropods
82 p. : ill. ; 24 cm.Includes bibliographical references (p. 69-82)
Genetic analysis of heterogeneous subsets of circulating tumour cells from high grade serous ovarian carcinoma patients
Circulating tumour cells (CTCs) are heterogenous and contain genetic information from the tumour of origin. They bear specific intra- and extra-cellular protein markers aiding in their detection. However, since these markers may be shared with other rare cells in the blood, only genetic testing can confirm their malignancy. Herein, we analyse different CTC subsets using single cell whole genome DNA sequencing to validate their malignant origin. We randomly selected putative CTCs identified by immunostaining that were isolated from 4 patients with high grade serous ovarian cancer (HGSOC) and one with benign cystadenoma. We specifically targeted CTCs positive for epithelial (CK/EpCAMpos), mesenchymal (vimentinpos), and pseudoendothelial (CK/EpCAMpos plus CD31pos) markers. We isolated these cells and performed whole genome amplification (WGA) and low-pass whole-genome sequencing (LP-WGS) for analysis of copy number alterations (CNA). Of the CK/EpCAMpos cells analysed from the HGSOC patients, 2 of 3 cells showed diverse chromosomal CNAs. However, the 4 pseudoendothelial cells (CK/EpCAMpos plus CD31pos) observed in the HGSOC cases did not carry any CNA. Lastly, two of the clusters of vimentin positive cells sequenced from those found in the benign cystadenoma case had CNA. Despite the low number of cells analysed, our results underscore the importance of genetic analysis of putative CTCs to confirm their neoplastic origin. In particular, it highlights the presence of a population of CK/EpCAMpos cells that are not tumour cells in patients with HGSOC, which otherwise would be counted as CTCs
- …