97 research outputs found

    Combination of PCR targeting the VD2 of omp1 and reverse line blot analysis for typing of urogenital Chlamydia trachomatis serovars in cervical scrape specimens.

    Get PDF
    50% contained both serovars D and E. The nested VD2 PCR-RLB developed is a simple, fast, and specific method for the identification of individual urogenital C. trachomatis serovars previously detected by using plasmid PCR. Moreover, it is an appropriate method for studying multiple C. trachomatis infections and for use in large epidemiological studies

    Micro-computed tomography of pulmonary fibrosis in mice induced by adenoviral gene transfer of biologically active transforming growth factor-β1

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Micro-computed tomography (micro-CT) is a novel tool for monitoring acute and chronic disease states in small laboratory animals. Its value for assessing progressive lung fibrosis in mice has not been reported so far. Here we examined the importance of in vivo micro-CT as non-invasive tool to assess progression of pulmonary fibrosis in mice over time.</p> <p>Methods</p> <p>Pulmonary fibrosis was induced in mice by intratracheal delivery of an adenoviral gene vector encoding biologically active TGF-ß1 (AdTGF-ß1). Respiratory gated and ungated micro-CT scans were performed at 1, 2, 3, and 4 weeks post pulmonary adenoviral gene or control vector delivery, and were then correlated with respective histopathology-based Ashcroft scoring of pulmonary fibrosis in mice. Visual assessment of image quality and consolidation was performed by 3 observers and a semi-automated quantification algorithm was applied to quantify aerated pulmonary volume as an inverse surrogate marker for pulmonary fibrosis.</p> <p>Results</p> <p>We found a significant correlation between classical Ashcroft scoring and micro-CT assessment using both visual assessment and the semi-automated quantification algorithm. Pulmonary fibrosis could be clearly detected in micro-CT, image quality values were higher for respiratory gated exams, although differences were not significant. For assessment of fibrosis no significant difference between respiratory gated and ungated exams was observed.</p> <p>Conclusions</p> <p>Together, we show that micro-CT is a powerful tool to assess pulmonary fibrosis in mice, using both visual assessment and semi-automated quantification algorithms. These data may be important in view of pre-clinical pharmacologic interventions for the treatment of lung fibrosis in small laboratory animals.</p

    The contribution of HPV18 to cervical cancer is underestimated using high-grade CIN as a measure of screening efficiency

    Get PDF
    In one geographical area, 14 high-risk human papillomavirus types in cervical intraepithelial neoplasia (CIN2/3; n=139) and cervical squamous cell carcinoma (SCC; n=84) were analysed. HPV18 was more prevalent in SCC than CIN2/3 (OR 9.8; 95% confidence interval: 2.5–39). Other high-risk types prevalences corresponded in CIN2/3 and SCC. Evaluations using CIN2/3 as a measure of efficiency underestimate the contribution of HPV18 to SCC

    Papillomavirus infection in rural women in southern India

    Get PDF
    To investigate the prevalence of, and the risk factors for, cervical infection with 44 types of human papillomavirus (HPV) in a rural area in the Dindigul District, Tamil Nadu, India, we interviewed and obtained cervical cell samples from 1891 married women aged 16–59 years. HPV prevalence was 16.9% overall and 14.0% among women without cervical abnormalities, or 17.7 and 15.2%, respectively, age-standardised to the world standard population. In all, 21.9% of infections involved more than one HPV type. High-risk HPV types predominated, particularly HPV 16 (22.5% of women infected), followed by HPV 56, HPV 31, HPV 33 and HPV 18. Unlike most populations studied in developed countries, HPV prevalence was constant across the age groups. HPV positivity was inversely associated with education level (odds ratio (OR) among women with high school vs no education=0.6) and positively associated with widowhood and divorce (OR=1.7), nulligravidity (OR=2.3), and condom use (OR=2.6). It is unclear how much low clearance of, or frequent reinfection with HPV accounted for the study prevalence of infection in different age groups

    Preferential risk of HPV16 for squamous cell carcinoma and of HPV18 for adenocarcinoma of the cervix compared to women with normal cytology in The Netherlands

    Get PDF
    We present the type-distribution of high-risk human papillomavirus (HPV) types in women with normal cytology (n=1467), adenocarcinoma in situ (ACIS) (n=61), adenocarcinoma (n=70), and squamous cell carcinoma (SCC) (n=83). Cervical adenocarcinoma and ACIS were significantly more frequently associated with HPV18 (ORMH 15.0; 95% CI 8.6–26.1 and 21.8; 95% CI 11.9–39.8, respectively) than normal cytology. Human papillomavirus16 was only associated with adenocarcinoma and ACIS after exclusion of HPV18-positive cases (ORMH 6.6; 95% CI 2.8–16.0 and 9.4; 95% CI 2.8–31.2, respectively). For SCC, HPV16 prevalence was elevated (ORMH 7.0; 95% CI 3.9–12.4) compared to cases with normal cytology, and HPV18 prevalence was only increased after exclusion of HPV16-positive cases (ORMH 4.3; 95% CI 1.6–11.6). These results suggest that HPV18 is mainly a risk factor for the development of adenocarcinoma whereas HPV16 is associated with both SCC and adenocarcinoma

    A second generation cervico-vaginal lavage device shows similar performance as its preceding version with respect to DNA yield and HPV DNA results

    Get PDF
    Contains fulltext : 118480.pdf (publisher's version ) (Open Access)BACKGROUND: Attendance rates of cervical screening programs can be increased by offering HPV self-sampling to non-attendees. Acceptability, DNA yield, lavage volumes and choice of hrHPV test can influence effectiveness of the self-sampling procedures and could therefore play a role in recruiting non-attendees. To increase user-friendliness, a frequently used lavage sampler was modified. In this study, we compared this second generation lavage device with the first generation device within similar birth cohorts. METHODS: Within a large self-sampling cohort-study among non-responders of the Dutch cervical screening program, a subset of 2,644 women received a second generation self-sampling lavage device, while 11,977 women, matched for age and ZIP-code, received the first generation model. The second generation device was different in shape, color, lavage volume, and packaging, in comparison to its first generation model. The Cochran's test was used to compare both devices for hrHPV positivity rate and response rate. To correct for possible heterogeneity between age and ZIP codes in both groups the Breslow-Day test of homogeneity was used. A T-test was utilized to compare DNA yields of the obtained material in both groups. RESULTS: Median DNA yields were 90.4 mug/ml (95% CI 83.2-97.5) and 91.1 mug/ml (95% CI 77.8-104.4, p= 0.726) and hrHPV positivity rates were 8.2% and 6.9% (p= 0.419) per sample self-collected by the second - and the first generation of the device (p= 0.726), respectively. In addition, response rates were comparable for the two models (35.4% versus 34.4%, p= 0.654). CONCLUSIONS: Replacing the first generation self-sampling device by an ergonomically improved, second generation device resulted in equal DNA yields, comparable hrHPV positivity rates and similar response rates. Therefore, it can be concluded that the clinical performance of the first and second generation models are similar. Moreover, participation of non-attendees in cervical cancer screening is probably not predominantly determined by the type of self-collection device

    Single-tube multiplex PCR using type-specific E6/E7 primers and capillary electrophoresis genotypes 21 human papillomaviruses in neoplasia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Human papillomavirus (HPV) <it>E6/E7 </it>type-specific oncogenes are required for cervical carcinogenesis. Current PCR protocols for genotyping high-risk HPV in cervical screening are not standardized and usually use consensus primers targeting HPV capsid genes, which are often deleted in neoplasia. PCR fragments are detected using specialized equipment and extra steps, including probe hybridization or primer extension. In published papers, analytical sensitivity is typically compared with a different protocol on the same sample set.</p> <p>A single-tube multiplex PCR containing type-specific primers was developed to target the <it>E6/E7 </it>genes of two low-risk and 19 high-risk genotypes (HPV6, 11 and 16, 18, 26, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68, 70, 73 and 82) and the resulting short fragments were directly genotyped by high-resolution fluorescence capillary electrophoresis.</p> <p>Results</p> <p>The method was validated using long oligonucleotide templates, plasmid clones and 207 clinical samples of DNA from liquid-based cytology, fresh and formalin-fixed specimens and FTA Microcards<sup>® </sup>imprinted with cut tumor surfaces, swabbed cervical cancers or ejected aspirates from nodal metastases of head and neck carcinomas. Between one and five long oligonucleotide targets per sample were detected without false calls. Each of the 21 genotypes was detected in the clinical sample set with up to five types simultaneously detected in individual specimens. All 101 significant cervical neoplasias (CIN 2 and above), except one adenocarcinoma, contained <it>E6/E7 </it>genes. The resulting genotype distribution accorded with the national pattern with HPV16 and 18 accounting for 69% of tumors. Rare HPV types 70 and 73 were present as the sole genotype in one carcinoma each. One cervical SCC contained DNA from HPV6 and 11 only. Six of twelve oropharyngeal cancer metastases and three neck metastases of unknown origin bore <it>E6/E7 </it>DNA; all but one were HPV16. One neck aspirate contained atypical squames with HPV26.</p> <p>Analytical sensitivity in dilute plasmid mixes was variable.</p> <p>Conclusions</p> <p>A primer-rich PCR readily detects the <it>E6/E7 </it>oncogenes of 21 HPV types in cellular and fixed tissue specimens. The method is straightforward, robust and reproducible and avoids post-PCR enzymatic and hybridization steps while detecting HPV with high clinical sensitivity in significant HPV-related neoplasia regardless of specimen type.</p

    A quantitative polymerase chain reaction-enzyme immunoassay for accurate measurements of human papillomavirus type 16 DNA levels in cervical scrapings

    Get PDF
    A quantitative polymerase chain reaction-enzyme immunoassay (Q-PCR-EIA) was developed to measure the amount of human papillomavirus (HPV) 16 DNA per genome equivalent in cervical scrapings. The quantitative approach was based on a combined competitive PCR for both HPV 16, using the general primer GP5+/6+ PCR, and β-globin DNA. The two competitive PCRs involve co-amplification of target sequences and exogenously added DNA constructs carrying a rearranged 30 bp sequence in the probe-binding region. The accuracy of quantification by combining the two competitive PCR assays was validated on mixtures of HPV 16 containing cervical cancer cells of CaSki and SiHa cell lines. Comparison of this fully quantitative PCR assay with two semi-quantitative HPV PCR assays on a series of crude cell suspensions from HPV 16 containing cervical scrapings revealed remarkable differences in the calculated relative HPV load between samples. We found evidence that correction for both intertube variations in PCR efficiency and number of input cells/integrity of DNA significantly influence the outcome of studies on viral DNA load in crude cell suspensions of cervical scrapings. Therefore, accurate measurements on viral DNA load in cervical scrapings require corrections for these phenomena, which can be achieved by application of this fully quantitative approach. © 1999 Cancer Research Campaig
    corecore