555 research outputs found

    Optimal duration of dual antiplatelet therapy after percutaneous coronary intervention or after acute coronary syndrome

    Get PDF
    To prevent recurrent ischaemic events, dual antiplatelet therapy (DAPT) is the standard of care after percutaneous coronary intervention and in the treatment of acute coronary syndrome. Recent evidence supports an adjusted DAPT duration in selected patients. The current paper aims to encourage cardiologists to actively search for patients benefiting from either shorter or prolonged duration DAPT and proposes an algorithm to identify patients who are likely to benefit from such an alternative strategy. Individualised DAPT duration should be considered in high-risk anatomic and/or clinical subgroups or in patients at increased haemorrhagic risk with low ischaemic risk. Both thrombotic and haemorrhagic risk should be assessed in all patients. In patients undergoing percutaneous coronary intervention, the interventional cardiologist could advise on the minimal duration of DAPT. However, in contrast to the minimum duration of DAPT for stent thrombosis prevention, longer duration DAPT is aimed at prevention of spontaneous myocardial infarction, and not at stent thrombos

    Angiography-based superficial wall strain of de novo stenotic coronary arteries:serial assessment of vessels treated with bioresorbable scaffold or drug-eluting stent

    Get PDF
    Objectives: This study sought to present an angiography-based computational model for serial assessment of superficial wall strain (SWS, dimensionless) of de-novo coronary stenoses treated with either bioresorbable scaffold (BRS) or drug-eluting stent (DES). Background: A novel method for SWS allows the assessment of the mechanical status of arteries in-vivo, which may help for predicting cardiovascular outcomes. Methods: Patients with arterial stenosis treated with BRS (n = 21) or DES (n = 21) were included from ABSORB Cohort B1 and AIDA trials. The SWS analyses were performed along with quantitative coronary angiography (QCA) at pre-PCI, post-PCI, and 5-year follow-up. Measurements of QCA and SWS parameters were quantified at the treated segment and adjacent 5-mm proximal and distal edges. Results: Before PCI, the peak SWS on the ‘to be treated’ segment (0.79 ± 0.36) was significantly higher than at both virtual edges (0.44 ± 0.14 and 0.45 ± 0.21; both p &lt; 0.001). The peak SWS in the treated segment significantly decreased by 0.44 ± 0.13 (p &lt; 0.001). The surface area of high SWS decreased from 69.97mm2 to 40.08mm2 (p = 0.002). The peak SWS in BRS group decreased to a similar extent (p = 0.775) from 0.81 ± 0.36 to 0.41 ± 0.14 (p &lt; 0.001), compared with DES group from 0.77 ± 0.39 to 0.47 ± 0.13 (p = 0.001). Relocation of high SWS to device edges was often observed in both groups after PCI (35 of 82 cases, 41.7 %). At follow-up of BRS, the peak SWS remained unchanged compared to post-PCI (0.40 ± 0.12 versus 0.36 ± 0.09, p = 0.319). Conclusion: Angiography-based SWS provided valuable information about the mechanical status of coronary arteries. Device implantation led to a significant decrease of SWS to a similar extent with either polymer-based scaffolds or permanent metallic stents.</p

    Side branch healing patterns of the Tryton dedicated bifurcation stent: a 1-year optical coherence tomography follow-up study

    Get PDF
    The bare-metal Tryton Side Branch (SB) Stent™ (Tryton Medical, Durham, NC, USA) is used with a drug-eluting stent (DES) in the main branch (MB) to treat bifurcation lesions. It is argued that a drug-eluting Tryton-version is needed to improve clinical outcomes, although previous registries have shown good clinical results. More insights in neo-intimal hyperplasia (NIH) growth patterns of the Tryton treatment strategy are needed to decide if and where to drug-coat the stent. Ten patients returned for follow-up angiography (mean follow-up time 393 ± 103 days) and optical coherence tomography (OCT) pullbacks from the MB were obtained in all patients and from the SB in six patients. A per-strut analysis showed an uncovered strut rate of 0.7 % and an incompletely-apposed strut rate of 0.8 %. Most incompletely-apposed struts were found at the bifurcation region, in the luminal half facing towards the SB. Mean NIH thickness in the proximal MB, distal MB and SB were 0.14 ± 0.11, 0.19 ± 0.11, and 0.34 ± 0.19 mm, respectively, with a variety of growth patterns observed in the SB. We found good vascular healing of the DES in the MB, while healing was less favourably in the SB part. Furthermore, we observed a variety of NIH growth patterns in this SB part and more studies are needed to investigate the relation between growth patterns and clinical outcomes