403 research outputs found
A Radio--Optical Reference Frame VIII. CCD observations from KPNO and CTIO: internal calibration and first results
In this pilot investigation, precise optical positions in the FK5 system are
presented for a set of 16 compact extragalactic radio sources, which will be
part of the future radio--optical reference frame. The 0.9 m KPNO and CTIO
telescopes equipped with 2K CCD's have been used for this project. The
astrometric properties of these instruments are investigated in detail. New
techniques of using wide field CCD observations for astrometry in general are
developed. An internal precision of 5 to 31 mas in position per single exposure
is found, depending on the brightness of the object. The tie to the primary
optical reference system is established by photographic astrometry using
dedicated astrographs on both hemispheres. An accuracy of mas per
source is estimated for the multi--step reduction procedure when based on the
future Hipparcos catalog, while the FK5--based positions suffer from system
errors of 100 to 200 mas as compared to the radio positions. This work provides
a contribution to the international effort to link the Hipparcos instrumental
coordinate system to the quasi--inertial VLBI radio reference frame. Precise
radio and optical astrometry of a large sample of compact extragalactic sources
will also contribute to the astrophysics of these objects by comparing the
respective centers of emission at the optical and radio wavelengths.Comment: AAS v.4 LaTeX, 2 parts on 1 file (main text + deluxetable), accepted
by AJ, Dec.95, fig. with reprint
The StarScan plate measuring machine: overview and calibrations
The StarScan machine at the U.S. Naval Observatory (USNO) completed measuring
photographic astrograph plates to allow determination of proper motions for the
USNO CCD Astrograph Catalog (UCAC) program. All applicable 1940 AGK2 plates,
about 2200 Hamburg Zone Astrograph plates, 900 Black Birch (USNO Twin
Astrograph) plates, and 300 Lick Astrograph plates have been measured. StarScan
comprises of a CCD camera, telecentric lens, air-bearing granite table, stepper
motor screws, and Heidenhain scales to operate in a step-stare mode. The
repeatability of StarScan measures is about 0.2 micrometer. The CCD mapping as
well as the global table coordinate system has been calibrated using a special
dot calibration plate and the overall accuracy of StarScan x,y data is derived
to be 0.5 micrometer. Application to real photographic plate data shows that
position information of at least 0.65 micrometer accuracy can be extracted from
course grain 103a-type emulsion astrometric plates. Transformations between
"direct" and "reverse" measures of fine grain emulsion plate measures are
obtained on the 0.3 micrometer level per well exposed stellar image and
coordinate, which is at the limit of the StarScan machine.Comment: 24 pages, 8 figures, accepted for PAS
Astrometric Positions and Proper Motions of 19 Radio Stars
We have used the Very Large Array, linked with the Pie Town Very Long
Baseline Array antenna, to determine astrometric positions of 19 radio stars in
the International Celestial Reference Frame (ICRF). The positions of these
stars were directly linked to the positions of distant quasars through phase
referencing observations. The positions of the ICRF quasars are known to 0.25
mas, thus providing an absolute reference at the angular resolution of our
radio observations. Average values for the errors in our derived positions for
all sources were 13 mas and 16 mas in R.A. and declination respectively, with
accuracies approaching 1-2 mas for some of the stars observed. Differences
between the ICRF positions of the 38 quasars, and those measured from our
observations showed no systematic offsets, with mean values of -0.3 mas in R.A.
and -1.0 mas in declination. Standard deviations of the quasar position
differences of 17 mas and 11 mas in R.A. and declination respectively, are
consistent with the mean position errors determined for the stars. Our measured
positions were combined with previous Very Large Array measurements taken from
1978-1995 to determine the proper motions of 15 of the stars in our list. With
mean errors of approximately 1.6 mas/yr, the accuracies of our proper motions
approach those derived from Hipparcos, and for a few of the stars in our
program, are better than the Hipparcos values. Comparing the positions of our
radio stars with the Hipparcos catalog, we find that at the epoch of our
observations, the two frames are aligned to within formal errors of
approximately 3 mas. This result confirms that the Hipparcos frame is inertial
at the expected level.Comment: 20 pages, 9 figures Accepted by the Astronomical Journal, 2003 March
1
Early CT and FDG-metabolic tumour volume changes show a significant correlation with survival in stage I-III small cell lung cancer: A hypothesis generating study
BACKGROUND: Many patients with stage I–III small cell lung cancer (SCLC) experience disease progression short after the completion of concurrent chemoradiotherapy (CRT). The purpose of the current study was to evaluate whether CT or FDG metabolic response early after the start of chemotherapy, but before the beginning of chest RT, is predictive for survival in SCLC. METHODS: Fifteen stage I–III SCLC patients treated with concurrent CRT with an FDG-PET and CT scan available before the start of chemotherapy and after or during the first cycle of chemotherapy, but before the start of radiotherapy, were selected. The metabolic volume (MV) was defined both within the primary tumour and in the involved nodal stations using the 40% (MV40) and 50% (MV50) threshold of the maximum SUV. Metabolic and CT response was assessed by the relative change in MV and CT volume, respectively, between both time points. The association between response and overall survival (OS) was analysed by univariate cox regression analysis. The minimum follow-up was 18 months. RESULTS: Reductions in MV40 and MV50 were −36 ± 38% (126.4 to 68.7 cm(3)) and −44 ± 38% (90.2 to 27.8 cm(3)), respectively. The median CT volume reduction was −40 ± 64% (190.6 to 113.8 cm(3)). MV40 and MV50 changes showed a significant association with survival (HR = 1.02, 95% CI: 1.00–1.04 (p = 0.042); HR = 1.02, 95% CI: 1.00–1.04 (p = 0.048), respectively), indicating a 2% increase in survival probability for 1% reduction in metabolic volume. The CT volume change was also significantly correlated with survival (HR = 1.01, 95% CI: 1.00–1.03, p = 0.007). CONCLUSIONS: This hypothesis generating study shows that both the early CT and the MV changes show a significant correlation with survival in SCLC. A prospective study is planned in a larger patient cohort to allow multivariate analysis, with the final aim to select patients early during treatment that could benefit from dose intensification or alternative treatment
Surfactant effect in heteroepitaxial growth. The Pb - Co/Cu(111) case
A MonteCarlo simulations study has been performed in order to study the
effect of Pb as surfactant on the initial growth stage of Co/Cu(111). The main
characteristics of Co growing over Cu(111) face, i.e. the decorated double
layer steps, the multiple layer islands and the pools of vacancies, disappear
with the pre-evaporation of a Pb monolayer. Through MC simulations, a full
picture of these complex processes is obtained. Co quickly diffuses through the
Pb monolayer exchanging place with Cu atoms at the substrate. The exchange
process diffusion inhibits the formation of pure Co islands, reducing the
surface stress and then the formation of multilayer islands and the pools of
vacancies. On the other hand, the random exchange also suppress the nucleation
preferential sites generated by Co atoms at Cu steps, responsible of the step
decoration.Comment: 4 pages, latex, 2 figures embedded in the tex
Assessing the role of tumour-associated macrophage subsets in breast cancer subtypes using digital image analysis
Purpose: The number of M1-like and M2-like tumour-associated macrophages (TAMs) and their ratio can play a role in breast cancer development and progression. Early clinical trials using macrophage targeting compounds are currently ongoing. However, the most optimal detection method of M1-like and M2-like macrophage subsets and their clinical relevance in breast cancer is still unclear. We aimed to optimize the assessment of TAM subsets in different breast cancer subtypes, and therefore related TAM subset numbers and ratio to clinicopathological characteristics and clinical outcome. Methods: Tissue microarrays of 347 consecutive primary Luminal-A, Luminal-B, HER2-positive and triple-negative tumours of patients with early-stage breast cancer were serially sectioned and immunohistochemically stained for the pan-macrophage marker CD68 and the M2-like macrophage markers CD163, CSF-1R and CD206. TAM numbers were quantified using a digital image analysis algorithm. M1-like macrophage numbers were calculated by subtracting M2-like TAM numbers from the total TAM number. Results: M2-like markers CD163 and CSF-1R showed a moderate positive association with each other and with CD68 (r ≥ 0.47), but only weakly with CD206 (r ≤ 0.06). CD68 + , CD163 + and CSF-1R + macrophages correlated with tumour grade in Luminal-B tumours (P < 0.001). Total or subset TAM numbers did not correlate with disease outcome in any breast cancer subtype. Conclusion: In conclusion, macrophages and their subsets can be detected by means of a panel of TAM markers and are related to unfavourable clinicopathological characteristics in Luminal-B breast cancer. However, their impact on outcome remains unclear. Preferably, this should be determined in prospective series
Renal uptake of different radiolabelled peptides is mediated by megalin: SPECT and biodistribution studies in megalin-deficient mice
Contains fulltext :
98302.pdf (publisher's version ) (Closed access)PURPOSE: Radiolabelled peptides used for peptide receptor radionuclide therapy are excreted mainly via the kidneys and are partly reabsorbed and retained in the proximal tubular cells. The resulting high renal radiation dose can cause nephrotoxicity, limiting the maximum activity dose and the effectiveness of peptide receptor radionuclide therapy. The mechanisms of kidney reabsorption of these peptides are incompletely understood, but the scavenger receptor megalin has been shown to play a role in the reabsorption of (111)In-octreotide. In this study, the role of megalin in the renal reabsorption of various relevant radiolabelled peptides was investigated. METHODS: Groups of kidney-specific megalin-deficient mice and wild-type mice were injected with (111)In-labelled somatostatin, exendin, neurotensin or minigastrin analogues. Single photon emission computed tomographic (SPECT) images of the kidneys were acquired and analysed quantitatively, or the animals were killed 3 h after injection and the activity concentration in the kidneys was measured. RESULTS: Megalin-deficient mice showed significantly lower uptake of all studied radiolabelled peptides in the kidneys, ranging from 22% ((111)In-octreotide) to 65% ((111)In-exendin) of uptake in wild-type kidneys. Quantitative analysis of renal uptake by SPECT and ex vivo measurements showed a very good correlation. CONCLUSION: Megalin is involved in the renal reabsorption of radiolabelled octreotide, octreotate, exendin, neurotensin and minigastrin. This knowledge may help in the design of strategies to reduce this reabsorption and the resulting nephrotoxicity in peptide receptor radionuclide therapy, enabling more effective therapy. Small-animal SPECT is an accurate tool, allowing in vivo quantification of renal uptake and serial measurements in individual mice
Glycogen synthase 1 targeting reveals a metabolic vulnerability in triple-negative breast cancer
BACKGROUND: Hypoxia-induced glycogen turnover is implicated in cancer proliferation and therapy resistance. Triple-negative breast cancers (TNBCs), characterized by a hypoxic tumor microenvironment, respond poorly to therapy. We studied the expression of glycogen synthase 1 (GYS1), the key regulator of glycogenesis, and other glycogen-related enzymes in primary tumors of patients with breast cancer and evaluated the impact of GYS1 downregulation in preclinical models.METHODS: mRNA expression of GYS1 and other glycogen-related enzymes in primary breast tumors and the correlation with patient survival were studied in the METABRIC dataset (n = 1904). Immunohistochemical staining of GYS1 and glycogen was performed on a tissue microarray of primary breast cancers (n = 337). In four breast cancer cell lines and a mouse xenograft model of triple-negative breast cancer, GYS1 was downregulated using small-interfering or stably expressed short-hairpin RNAs to study the effect of downregulation on breast cancer cell proliferation, glycogen content and sensitivity to various metabolically targeted drugs.RESULTS: High GYS1 mRNA expression was associated with poor patient overall survival (HR 1.20, P = 0.009), especially in the TNBC subgroup (HR 1.52, P = 0.014). Immunohistochemical GYS1 expression in primary breast tumors was highest in TNBCs (median H-score 80, IQR 53-121) and other Ki67-high tumors (median H-score 85, IQR 57-124) (P < 0.0001). Knockdown of GYS1 impaired proliferation of breast cancer cells, depleted glycogen stores and delayed growth of MDA-MB-231 xenografts. Knockdown of GYS1 made breast cancer cells more vulnerable to inhibition of mitochondrial proteostasis.CONCLUSIONS: Our findings highlight GYS1 as potential therapeutic target in breast cancer, especially in TNBC and other highly proliferative subsets.</p
- …