6 research outputs found

    Use of Polypropylene Strips for Reinforcement of the Cruroplasty in Laparoscopic Paraesophageal Hernia Repair: A Retrospective Cohort Study

    No full text
    Introduction: Laparoscopic paraesophageal hernia repair is an effective treatment for symptomatic paraesophageal hernias. To reduce recurrence rates, the use of prosthetics for the crural repair has been suggested. Mesh-related complications are rare but known to be disastrous. To address another form of crural repair, polypropylene strips are suggested. This study aimed to assess peri-and postoperative complications of reinforcement of cruroplasty with polypropylene strips. Methods: From 2013 to 2020, patients with a primary or recurrent type 2, 3, or 4 paraesophageal hernia that underwent cruroplasty with polypropylene strips were retrospectively reviewed. Intra-and postoperative complications were graded according to the Clavien-Dindo classification. The incidence of symptomatic recurrent hiatal hernia (CT or endoscopy proven) and hospital stay were assessed. Results: One hundred fifty-eight patients were included. Mean age was 65 years (standard deviation 10.4), and 119 patients were female (75.3%). Almost 50% of surgeries took place between 2018 and 2020. Median follow-up was 7 months (interquartile range 17.5). Mean operation time in the primary hernia group was 159 min (standard deviation 39.0), and length of stay was 4.4 days. In 3/158 patients (2.0%), intraoperative complications occurred. Two patients developed a grade 4 and seven patients a grade 3 postoperative complication. No mortality was recorded. Twelve recurrences (8.2%) were detected in the primary hernia group and one (9.1%) in the recurrent hernia group. Conclusion: There were no mesh-related complications seen and symptomatic recurrence rate was low, but longer follow-up is needed

    A new three-step hybrid approach is a safe procedure for incisional hernia: early experiences with a single centre retrospective cohort

    Get PDF
    Purpose: In this study, a three-step novel surgical technique was developed for incisional hernia, in which a laparoscopic procedure with a mini-laparotomy is combined: so-called ‘three-step incisional hybrid repair’. The aim of this study was to reduce the risk of intestinal lacerations during adhesiolysis and recurrence rate by better symmetrical overlap placement of the mesh. Objectives: To evaluate first perioperative outcomes with this technique. Methods: From 2016 to 2020, 70 patients (65.7% females) with an incisional hernia of > 2 and ≤ 10 cm underwent a elective three-step incisional hybrid repair in two non-academic hospitals performed by two surgeons specialised in abdominal wall surgery. Intra- and postoperative complications, operation time, hospitalisation time and hernia recurrence were assessed. Results: Mean operation time was 100 min. Mean hernia size was 4.8 cm; 45 patients (64.3%) had a hernia of 1–5 cm, 25 patients (35.7%) of 6–10 cm. Eight patients had a grade 1 complication (11.4%), five patients a grade 2 (7.1%), two patients (2.8%) a grade 4 complication and one patient (1.4%) a grade 5 complication. Five patients had an intraoperative complication (7.0%), two enterotomies, one serosa injury, one omentum bleeding and one laceration of an epigastric vessel. Mean length of stay was 3.3 days. Four patients (5.6%) developed a hernia recurrence during a mean follow-up of 19.5 weeks. Conclusion: A three-step hybrid incisional hernia repair is a safe alternative for incisional hernia repair. Intraoperative complications rate was low

    Medialization after combined anterior and posterior component separation in giant incisional hernia surgery, an anatomical study

    Get PDF
    Background: To obtain tension-free closure for giant incisional hernia repair, anterior or posterior component separation is often performed. In patients with an extreme diameter hernia, anterior component separation and posterior component separation may be combined. The aim of this study was to assess the additional medialization after simultaneous anterior component separation and posterior component separation. Methods: Fresh-frozen post mortem human specimens were used. Both sides of the abdominal wall were subjected to retro-rectus dissection (Rives-Stoppa), anterior component separation and posterior component separation, the order in which the component separation techniques were performed was reversed for the contralateral side. Medialization was measured at 3 reference points. Results: Anterior component separation provided most medialization for the anterior rectus sheath, posterior component separation provided most medialization for the posterior rectus sheath. After combined component separation techniques total median medialization ranged between 5.8 and 9.2 cm for the anterior rectus sheath, and between 10.1 and 14.2 cm for the posterior rectus sheath (depending on the level on the abdomen). For the anterior rectus sheath, additional posterior component separation after anterior component separation provided 15% to 16%, and additional anterior component separation after posterior component separation provided 32% to 38% of the total medialization after combined component separation techniques. For the posterior rectus sheath, additional posterior component separation after anterior component separation provided 50% to 59%, and additional anterior component separation after posterior component separation provided 11% to 17% of the total medialization after combined component separation techniques. Retro-rectus dissection alone contributed up to 41% of maximum obtainable medialization. Conclusion: Anterior component separation provided most medialization of the anterior rectus sheath and posterior component separation provided most medialization of the posterior rectus sheath. Combined component separation techniques provide marginal additional medialization, clinical use of this technique should be carefully balanced against additional risks

    Outcomes of Incisional Hernia Repair Surgery After Multiple Re-recurrences: A Propensity Score Matched Analysis

    Get PDF
    Background: Patients with a re-recurrent hernia may account for up to 20% of all incisional hernia (IH) patients. IH repair in this population may be complex due to an altered anatomical and biological situation as a result of previous procedures and outcomes of IH repair in this population have not been thoroughly assessed. This study aims to assess outcomes of IH repair by dedicated hernia surgeons in patients who have already had two or more re-recurrences. Methods: A propensity score matched analysis was performed using a registry-based, prospective cohort. Patients who underwent IH repair after ≥ 2 re-recurrences operated between 2011 and 2018 and who fulfilled 1 year follow-up visit were included. Patients with similar follow-up who underwent primary IH repair were propensity score matched (1:3) and served as control group. Patient baseline characteristics, surgical and functional outcomes were analyzed and compared between both groups. Results: Seventy-three patients operated on after ≥ 2 IH re-recurrences were matched to 219 patients undergoing primary IH repair. After propensity score matching, no significant differences in patient baseline characteristics were present between groups. The incidence of re-recurrence was similar between groups (≥ 2 re-recurrences: 25% versus control 24%, p = 0.811). The incidence of complications, as well as long-term pain, was similar between both groups. Conclusion: IH repair in patients who have experienced multiple re-recurrences results in outcomes comparable to patients operated for a primary IH with a similar risk profile. Further surgery in patients who have already experienced multiple hernia re-recurrences is justifiable when performed by a dedicated hernia surgeon
    corecore