18 research outputs found
Cover plants and performance of shanks depths under corn productivity
The direct sowing system is characterized by minimum soil rotation and maintenance of vegetal residues in cover. However, incorrect management excessive traffic of machines have caused the emergence of compacted layers, which can cause decrease of crop productivity. The objective of this work was to evaluate the soil parameters and maize crop yield after management with different performance depths of fertilizer shanks, associated to the cultivation of winter coverage plants, in compacted Latosol, conducted in a direct sowing system. The experiment was carried out in two agricultural years (2013/2014 and 2014/2015), in a dystroferric Red Latosol, with a very clayey texture. The experiment was conducted in a randomized complete block design, with treatments arranged in the strip scheme, with two factors and four replications, totaling 32 experimental units. The main treatments were composed by the combination of four performance depths of fertilizer shank (0.065, 0.095, 0.125 and 0.150 m) in the corn sowing process and the secondary ones by the cultivation of two winter coverage plants (black oats and turnip forage). The use of coverage plants and performance depths of the shank, among themselves, did not change the parameters of soil density and porosity, in the intercrop line. The final population of plants, seedling emergence speed index and maize production components did not vary as a result of the performance depth of the shank
Conditions of use of boom sprayers in the micro-region of Pato Branco, PR, Brazil
The technical inspection of agricultural sprayers is responsible for generating important subsidies to inform and guide their users. In this sense, the aim of this study was to evaluate the working conditions of boom sprayers regarding their conservation status in order to identify the problems that interfere with quality sprayings. Sixty-three agricultural sprayers from rural properties were evaluated in the micro-region of Pato Branco, PR. Less than half of applicators (42.9%) performed some type of training and 58.7% of the operators had knowledge about the working pressure indicated by the spray tip manufacturer, but 24.3% of them were working with the pressure out of the recommended or with a damaged manometer. The manometer was present and operative in only 71.4% of the sprayers. Only 54% of the collected flows were in accordance with that informed by the operator. Most of the interviewed producers still do not have adequate criteria for choosing spray tips nor frequency of their replacement
Fatores técnicos intervenientes na realização do exame de eletrorretinograma multifocal (ERGmf) Technical factors that influence multifocal electroretinogram (mfERG) recording
OBJETIVO: Descrever os principais fatores intervenientes observados durante a aquisição e análise do exame de eletrorretinograma multifocal (ERGmf), que afetam o registro gráfico das ondas obtidas e portanto sua análise. MÉTODOS: Análise dos fatores de erro observados durante a aquisição de 100 exames seqüenciais de eletrorretinograma multifocal, realizados com o Reti System da Roland Consult, no período de maio a julho de 2005. Os exames de eletrorretinograma multifocal foram realizados conforme recomendações internacionais, respeitando-se os parâmetros preestabelecidos do equipamento, com 61 elementos, e ângulo visual de 30º. Todos os pacientes foram submetidos à avaliação oftalmológica completa, excluindo-se aqueles com transparência inadequada de meios, córneas planas e os incapazes de visualizar as linhas de fixação. RESULTADOS: Os fatores intervenientes, que poderiam causar erros na interpretação dos resultados obtidos, observados e corrigidos durante a realização dos exames foram: fixação excêntrica, movimentação dos olhos, contração do orbicular, contração da musculatura cervical, não-correção adequada, não-transparência adequada do eletrodo corneano, deslocamento do eletrodo em geral para baixo, descentralização do suporte da lente corretora, distância inadequada paciente-monitor em pacientes com alta ametropia, altura inadequada dos olhos em relação ao centro da tela, ruído na freqüência de 60 HZ (rede elétrica) e de campo eletromagnético, impedâncias elevadas. No processamento das ondas, a utilização excessiva de filtros para remoção de ruídos dos registros obtidos, pode interferir na análise dos resultados obtidos. CONCLUSÕES: Cuidados simplesmente observacionais durante a aquisição dos sinais são de importância significativa para a obtenção de registros com boa morfologia e baixo nível de ruído. Permitindo, por meio de sua pronta correção, a análise correta e adequada da amplitude e do tempo implícito dos picos N1 e P1, fundamentais para a corroboração diagnóstica de lesões ou afecções retinianas.<br>PURPOSE: To describe the main intervening factors observed during the acquisition and analysis of multifocal electroretinogram (mfERG), that could affect the recorded signal, the obtained responses and their analysis. METHODS: The error factors observed during the acquisition of 100 sequential multifocal electroretinogram tests, in the period of May to July, 2005 were analyzed. The examinations of multifocal electroretinogram were carried out in agreement with international guideline recommendations, taking into account the established parameters of equipment, with 61 elements, and visual angle of 30º. All patients had been submitted to complete ophthalmologic examination, excluding those with inadequate transparency of ways, flat corneas and those incapable to visualize a central fixation target. RESULTS: The intervening factors, that could cause artifacts and errors in the interpretation of the obtained results, observed and corrected during the acquisition of multifocal electroretinogram were: eccentric or poor fixation, eye movements, orbicular contraction, cervical muscle contraction, inadequate transparency of the corneal electrode, electrode displacement, lens support decentralization, inadequate viewing distance in patients with high refractive errors, eye height inadequacy in relation to the center of the screen, electrical noise in 60 HZ frequency and electromagnetic field and high impedances. Excessive use of filters in wave processing for noise and artifact removal can interfere with the analysis of the obtained results. CONCLUSION: Simple observational cares during signal acquisition are of significant importance to ensure accuracy of the topographical electroretinogram information, good waveform morphology and low noise level register. Through their ready correction, the correct and adjusted analysis of the amplitude and of implicit time of peaks N1, P1 and N2 is reliable. Digital smooth system with specific frequency peak removal supply waves with more defined morphology with lower amplitude reduction than other available resources
Abordagem multidisciplinar no trauma facial: um relato de caso
Introdução: Em todo o mundo, diversas medidas de segurança têm sido aplicadas para minimizar os danos relacionados aos acidentes de trabalho. Ainda assim, muitos casos são rotineiramente encaminhados aos Prontos Socorros do Sistema Único de Saúde (SUS), particularmente nas zonas rurais. Objetivo: Relatar a abordagem multidisciplinar de um caso de traumatismo facial grave secundário a acidente de trabalho atendido no Conjunto Hospitalar de Sorocaba (CHS). Relato do Caso: Paciente masculino, 19 anos, branco, trabalhador rural, vítima de trauma após ter saltado de um trator em movimento durante o exercício de sua atividade laboral, trazido por seus familiares com hemiface direita, desfigurada pela avulsão da pele e da musculatura com exposição óssea, caracterizada à TC como fratura complexa zigomático-maxilar Le Fort tipo 2 à direita além da destruição do seio maxilar, do assoalho da órbita e dos rebordos orbitários lateral, superior e inferior. A abordagem cirúrgica foi realizada pelas equipes de Cirurgia Plástica, Cirurgia Bucomaxilofacial e Cirurgia Oftalmológica que procederam à reconstrução óssea por placas de titânio, estabilização da arcada dentária superior por amarramento e reposicionamento das partes moles. O globo ocular foi preservado por apresentar-se íntegro. Conclusões: A abordagem multidisciplinar das fraturas faciais complexas busca primariamente restaurar a complexa anatomia de toda essa região por primeira intenção. Considerando tratar-se de fratura secundária a um “acidente de trabalho”, ilustramos aqui uma trágica consequência do não uso dos equipamentos de proteção individual e da inobservância das normas de segurança