10 research outputs found

    Experimental and numerical study on the T-Stub behaviour with preloaded bolts under large deformations

    No full text
    The bolts and their arrangement strongly influence stiffness, strength and ductility of T-Stub connections. Preloaded bolts are typically adopted to improve the stiffness and limit the opening of the connection under serviceability conditions. EN1993-1-8 allows using two types of high resistance preloaded bolts, namely the German HV (acronym of Hochfeste Bolzen mit Vorspannung, which is the German for High Resistance bolts for pretension and the British/French HR (acronym of High Resistance) without making any distinction. However, the tensile failure modes of these bolts are different (i.e. nut stripping for HV and shank necking for HR) and may affect the ultimate tensile response of the T-Stub connections with weak bolts (e.g. failure mode type 2 and 3). Furthermore, despite the effects of geometrical non-linearities at large deformations are not specifically addressed in current codes, the membrane action developing in the flange and the shear force and bending moment in the bolt may influence the reserve of ductility of the T-Stub that plays an important role in case of seismic and robustness scenarios. In addition, the presence of initial imperfections (e.g. the misalignment of the web as respect to the bolts and the flange bowing) can influence the non-linear behaviour of the connection. The influence of all these aspects on resistance and ductility of T-Stub connections are investigated by means of both experimental monotonic tests and parametric finite element analyses. On the basis of the obtained results, design rules are discussed with the aim to guarantee extra ductility of T-Stub connections

    Finite element modelling of detachable short links

    No full text
    Eccentrically braced frames with replaceable links are viable seismic resisting systems that guarantee large dissipative capacity and quick and easy replacement of the damaged dissipative zones after seismic events, thus reducing the repair costs. Experimental tests carried out within DUAREM research project [12] demonstrated the high effectiveness of this system and highlighted the importance of the bolted connections of the shear links on the system response at both global and local level. In order to investigate the behaviour of the tested detachable links, finite element analyses have been carried out. The finite element (FE) models are calibrated on the basis of the experimental response curves in terms of the shear force and link rotation. Once calibrated the finite element models, several parameters have been investigated such as the type of pre-loadable bolts (i.e. HR and HV), the level of bolt clamping force, the boundary conditions, the presence of constructional tolerances (e.g. initial gap between end-plate at both link ends). The results from the parametric study enables the characterization of the shear and axial force interaction on the link end connections

    Removable friction dampers for low-damage steel beam-to-column joints

    No full text
    Beam-to-column joints equipped with friction dampers are promising solutions to improve the performance of steel moment resisting frames due to the possibility to guarantee large dissipation capacity limiting the structural damage under severe seismic conditions. In this paper, the experimental tests and the numerical simulations of two types of joints are shown and discussed with the aim of developing pre-qualified configurations. The friction dampers are designed to be easily removable from both the lower beam flange and the column face by means of bolted connections. The devices are composed of a stack of steel plates conceived to assure symmetrical friction. The friction surface is set in vertical direction in first case and in horizontal direction in the second type. The experimental tests confirmed the effectiveness of both examined joints and the finite element analyses allowed characterizing their local response, thus providing additional insights to improve the design requirements

    Robustness of seismically pre-qualified extended stiffened beam-to-column joints

    No full text
    Steel joints for moment resisting frames in seismic areas are designed in accordance with the capacity-based design principles This design philosophy can be also effectively implemented to enhance the robustness of structures against progressive collapse. In this article the effectiveness of seismic design criteria on the robustness of beam-to-column joints is investigated. The numerical investigation was carried out on a set of European beam-to-column assemblies equipped with extended stiffened end-plate connections. The beams in the analyzed models were axially-restrained and subjected to large rotational demands, characteristic of the column loss scenario. The results show that the joints designed in accordance with seismic requirements have an adequate performance, provided that the axial resistance of half of the connection is larger than the plastic resistance of the beam

    Finite element analyses on free from damage seismic resisting beam-to-column joints

    No full text
    The seismic design strategy implemented in current codes is based on the capacity design principles that allow the formation of plastic hinges into predefined parts of the structure. Therefore, significant damage is expected at ultimate limit state, to which high repair costs are associated. Recently, new design strategies have been proposed in order to avoid the damage of the structure. The most of them are grouped into two categories, namely i) using special damping devices introduced in the structure as additional resisting element; ii) changing the dissipation mechanism of the structure by means of friction-based dissipative joints. The second possibility is promising and really effective because it guarantees no architectural interference if adopted for moment-resisting frames (MRFs), and low forces transferred to the foundations. The novelty of free from damage (FREEDAM) joints lays in the fact that the energy is dissipated by friction at the interface between plates in contact instead of the classical plastic deformation energy dissipation mechanism. In this paper, the seismic behaviour of FREEDAM joints is investigated by means of parametric finite element analyses carried out in order to examine the influence of geometric and mechanical feature of the friction device (e.g. position of friction plane, type of friction interface, bolt clamping, bolt strength). The accuracy of finite element models is also validated on the basis of some experimental tests

    The fire behaviour of extended stiffened joints designed for seismic actions

    No full text
    The structural behaviour of steel moment resisting frames (MRFs) is strongly dependent on the beam-to-column joint behaviour. The role of the joints is crucial especially under accidental natural and human induced actions, as in the cases of earthquake and fire scenarios, which can occur subsequently after severe seismic events in urban areas. The study summarized in this paper aims at investigating the fire behaviour of seismically designed extended stiffened end-plate joint by means of finite element analyses (FEAs). The joint performance was investigated considering two scenarios: (i) in the first case the assemblies were subjected only to the fire action; (ii) in the second scenario the fire actions were applied to seismically damaged joints. The numerical results show that the fire action changes the restraining capacity of the joint, and local failure can also occur, especially when fire occurs after severe seismic damage

    Seismic response of steel Moment Resisting Frames equipped with friction beam-to-column joints

    No full text
    The use of supplementary dissipative devices is an effective design strategy to improve the seismic response of structures. Friction devices inserted into beam-to-column joints can be a viable solution to optimize the seismic performance of steel Moment Resisting Frames (MRFs). The joints equipped with such devices are full rigid but very ductile partial strength, whose resistance can be easily calibrated to match the EC8 design moments with negligible overstrength. On the contrary, EC8-compliant MRFs equipped with traditional full-strength joints are often characterized by large beam overstrength due to the need to satisfy both serviceability and stability checks that lead largely oversizing the columns. In this paper, three design criteria for MRFs equipped with friction beam-to-column joints are described and examined by means non-linear static and dynamic analyses. The discussion of the results highlights the benefits of friction joints as well as the effectiveness of the examined design criteria