13 research outputs found

    Curiosity model policy optimization for robotic manipulator tracking control with input saturation in uncertain environment

    Get PDF
    In uncertain environments with robot input saturation, both model-based reinforcement learning (MBRL) and traditional controllers struggle to perform control tasks optimally. In this study, an algorithmic framework of Curiosity Model Policy Optimization (CMPO) is proposed by combining curiosity and model-based approach, where tracking errors are reduced via training agents on control gains for traditional model-free controllers. To begin with, a metric for judging positive and negative curiosity is proposed. Constrained optimization is employed to update the curiosity ratio, which improves the efficiency of agent training. Next, the novelty distance buffer ratio is defined to reduce bias between the environment and the model. Finally, CMPO is simulated with traditional controllers and baseline MBRL algorithms in the robotic environment designed with non-linear rewards. The experimental results illustrate that the algorithm achieves superior tracking performance and generalization capabilities

    The ratio of CRP to prealbumin levels predict mortality in patients with hospital-acquired acute kidney injury

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Animal and human studies suggest that inflammation and malnutrition are common in acute kidney injury (AKI) patients. However, only a few studies reported CRP, a marker of inflammation, albumin, prealbumin and cholesterol, markers of nutritional status were associated with the prognosis of AKI patients. No study examined whether the combination of inflammatory and nutritional markers could predict the mortality of AKI patients.</p> <p>Methods</p> <p>155 patients with hospital-acquired AKI were recruited to this prospective cohort study according to RIFLE (Risk, Injury, Failure, Lost or End Stage Kidney) criteria. C-reactive protein (CRP), and the nutritional markers (albumin, prealbumin and cholesterol) measured at nephrology consultation were analyzed in relation to all cause mortality of these patients. In addition, CRP and prealbumin were also measured in healthy controls (n = 45), maintenance hemodialysis (n = 70) and peritoneal dialysis patients (n = 50) and then compared with AKI patients.</p> <p>Results</p> <p>Compared with healthy controls and end-stage renal disease patients on maintenance hemodialysis or peritoneal dialysis, patients with AKI had significantly higher levels of CRP/prealbumin (<it>p </it>< 0.001). Higher level of serum CRP and lower levels of albumin, prealbumin and cholesterol were found to be significant in the patients with AKI who died within 28 days than those who survived >28 days. Similarly, the combined factors including the ratio of CRP to albumin (CRP/albumin), CRP/prealbumin and CRP/cholesterol were also significantly higher in the former group (<it>p </it>< 0.001 for all). Multivariate analysis (Cox regression) revealed that CRP/prealbumin was independently associated with mortality after adjustment for age, gender, sepsis and sequential organ failure assessment (SOFA, <it>p </it>= 0.027) while the others (CRP, albumin, prealbumin, cholesterol, CRP/albumin and CRP/cholesterol) became non-significantly associated. The hazard ratio was 1.00 (reference), 1.85, 2.25 and 3.89 for CRP/prealbumin increasing according to quartiles (<it>p </it>= 0.01 for the trend).</p> <p>Conclusions</p> <p>Inflammation and malnutrition were common in patients with AKI. Higher level of the ratio of CRP to prealbumin was associated with mortality of AKI patients independent of the severity of illness and it may be a valuable addition to SOFA score to independent of the severity of illness and it may be a valuable addition to SOFA score to predict the prognosis of AKI patients.</p

    All-Fiber In-Line Twist Sensor Based on a Capillary Optical Fiber

    No full text
    Twist sensors have emerged as crucial tools in the field of structural health monitoring, playing a significant role in monitoring and ensuring the integrity of critical infrastructure such as dams, tunnels, bridges, pipelines, and buildings. We proposed and demonstrated an all-fiber in-line twist sensor which was based on a capillary fiber spliced between two single-mode fibers with a transverse offset. Through a series of experiments, the sensor’s performance was evaluated and quantified. The results showcased remarkable twist sensitivities in both clockwise and anticlockwise directions. With a transverse offset of 8.0 µm, the sensor exhibited twist sensitivities of −0.077 dB/° and 0.043 dB/° in the clockwise and anticlockwise directions, respectively, in the measured twist range from 0 to 90°. Furthermore, it was also demonstrated that the sensor was temperature insensitive at the chosen wavelength of 1520 nm, which can assist in increasing measurement accuracy. Our sensor’s low cost, simplicity of manufacture, and improved performance will push forward its adoption in future engineering applications such as structural health monitoring in dams, tunnels, and buildings

    Film Thickness-Profile Measurement Using Iterative Peak Separation Structured Illumination Microscopy

    No full text
    The surface and thickness distribution measurement for transparent film is of interest for electronics and packaging materials. Structured illumination microscopy (SIM) is a prospective technique for measuring film due to its high accuracy and efficiency. However, when the distance between adjacent layers becomes close, the peaks of the modulation depth response (MDR) start to overlap and interfere with the peak extraction, which restricts SIM development in the field of film measurement. In this paper, an iterative peak separation algorithm is creatively applied in the SIM-based technique, providing a precise peak identification even as the MDR peaks overlap and bend into one. Compared with the traditional method, the proposed method has a lower detection threshold for thickness. The experiments and theoretical analysis are elaborated to demonstrate the feasibility of the mentioned method

    Optical Sectioning Microscopy for Multilayer Structure With Micro-Scale Air Gaps Measurement

    No full text

    Profilometry With Enhanced Accuracy Using Differential Structured Illumination Microscopy

    No full text

    Selecting a Proper Microsphere to Combine Optical Trapping with Microsphere-Assisted Microscopy

    No full text
    Microsphere-assisted microscopy serves as an effective super-resolution technique in biological observations and nanostructure detections, and optical trapping is widely used for the manipulation of small particles like microspheres. In this study, we focus on the selection of microsphere types for the combination of the optical trapping and the super-resolution microsphere-assisted microscopy, by considering the optical trapping performances and the super-resolution imaging ability of index-different microspheres in water simultaneously. Finally, the polystyrene (PS) sphere and the melamine formaldehyde (MF) sphere have been selected from four typical index-different microspheres normally used in microsphere-assisted microscopy. In experiments, the optically trapped PS/MF microsphere in water has been used to achieve super-resolution imaging of a 139 nm line-width silicon nanostructure grating under white light illumination. The image quality and the magnification factor are affected by the refractive index contrast between the microspheres and the immersion medium, and the difference of image quality is partly explained by the photonic nanojet. This work guides us in selecting proper microspheres, and also provides a label-free super-resolution imaging technique in many research fields
    corecore