69 research outputs found
Is the alien species Clepsis peritana (Lepidoptera: Tortricidae) settling in Italy?
Clepsis peritana (Clemens, 1860) is a native species of North America that has been accidentally introduced in Europe in 80’s. This species was mentioned as occurring in Gibraltar, Spain, Denmark and Italy, but no precise collecting data were provided. The presence of the garden tortrix, Clepsis peritana, in Italy is confirmed by a single specimen collected in Central Italy (Umbria region) that is identified by both external characters and dissection of the male genitalia
CT based radiomic approach on first line pembrolizumab in lung cancer
Clinical evaluation poorly predicts outcomes in lung cancer treated with immunotherapy. The aim of the study is to assess whether CT-derived texture parameters can predict overall survival (OS) and progression-free survival (PFS) in patients with advanced non-small-cell lung cancer (NSCLC) treated with first line Pembrolizumab. Twenty-one patients with NSLC were prospectively enrolled; they underwent contrast enhanced CT (CECT) at baseline and during Pembrolizumab treatment. Response to therapy was assessed both with clinical and iRECIST criteria. Two radiologists drew a volume of interest of the tumor at baseline CECT, extracting several texture parameters. ROC curves, a univariate Kaplan-Meyer analysis and Cox proportional analysis were performed to evaluate the prognostic value of texture analysis. Twelve (57%) patients showed partial response to therapy while nine (43%) had confirmed progressive disease. Among texture parameters, mean value of positive pixels (MPP) at fine and medium filters showed an AUC of 72% and 74% respectively (P < 0.001). Kaplan-Meyer analysis showed that MPP < 56.2 were significantly associated with lower OS and PFS (P < 0.0035). Cox proportional analysis showed a significant correlation between MPP4 and OS (P = 0.0038; HR = 0.89[CI 95%:0.83,0.96]). In conclusion, MPP could be used as predictive imaging biomarkers of OS and PFS in patients with NSLC with first line immune treatment
Magnetic resonance of rectal cancer response to therapy: an Image quality comparison between 3.0 and 1.5 Tesla
Purpose. To evaluate signal intensity (SI) differences between 3.0 T and 1.5 T on T2-weighted (T2w), diffusion-weighted imaging (DWI), and apparent diffusion coefficient (ADC) in rectal cancer pre-, during, and postneoadjuvant chemoradiotherapy (CRT). Materials and Methods. 22 patients with locally advanced rectal cancer were prospectively enrolled. All patients underwent T2w, DWI, and ADC pre-, during, and post-CRT on both 3.0 T MRI and 1.5 T MRI. A radiologist drew regions of interest (ROIs) of the tumor and obturator internus muscle on the selected slice to evaluate SI and relative SI (rSI). Additionally, a subanalysis evaluating the SI before and after-CRT (ΔSI pre-post) in complete responder patients (CR) and nonresponder patients (NR) on T2w, DWI, and ADC was performed. Results. Significant differences were observed for T2w and DWI on 3.0 T MRI compared to 1.5 T MRI pre-, during, and post-CRT (all P<0.001), whereas no significant differences were reported for ADC among all controls (all P>0.05). rSI showed no significant differences in all the examinations for all sequences (all P>0.05). ΔSI showed significant differences between 3.0 T and 1.5 T MRI for DWI-ΔSI in CR and NR (188.39±166.90 vs. 30.45±21.73 and 169.70±121.87 vs. 22.00±31.29, respectively, all P 0.02) and ADC-ΔSI for CR (-0.58±0.27 vs. -0.21±0.24P value 0.02), while no significant differences were observed for ADC-ΔSI in NR and both CR and NR for T2w-ΔSI. Conclusion. T2w-SI and DWI-SI showed significant differences for 3.0 T compared to 1.5 T in all three controls, while ADCSI showed no significant differences in all three controls on both field strengths. rSI was comparable for 3.0 T and 1.5 T MRI in rectal cancer patients; therefore, rectal cancer patients can be assessed both at 3.0 T MRI and 1.5 T MRI. However, a significant DWI-ΔSI and ADC-ΔSI on 3.0 T in CR might be interpreted as a better visual assessment in discriminating response to therapy compared to 1.5 T. Further investigations should be performed to confirm future possible clinical application
Fast high-quality MRI protocol of the lumbar spine with deep learning-based algorithm: an image quality and scanning time comparison with standard protocol
Objective: The objective of this study is to prospectively compare quantitative and subjective image quality, scanning time, and diagnostic confidence between a new deep learning-based reconstruction(DLR) algorithm and standard MRI protocol of lumbar spine. Materials and methods: Eighty healthy volunteers underwent 1.5T MRI examination of lumbar spine from September 2021 to May 2023. Protocol acquisition comprised sagittal T1- and T2-weighted fast spin echo and short-tau inversion recovery images and axial multislices T2-weighted fast spin echo images. All sequences were acquired with both DLR algorithm and standard protocols. Two radiologists, blinded to the reconstruction technique, performed quantitative and qualitative image quality analysis in consensus reading; diagnostic confidence was also assessed. Quantitative image quality analysis was assessed by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Qualitative image quality analysis and diagnostic confidence were assessed with a five-point Likert scale. Scanning times were also compared. Results: DLR SNR was higher in all sequences (all p<0.001). CNR of the DLR was superior to conventional dataset only for axial and sagittal T2-weighted fast spin echo images (p<0.001). Qualitative analysis showed DLR had higher overall quality in all sequences (all p<0.001), with an inter-rater agreement of 0.83 (0.78-0.86). DLR total protocol scanning time was lower compared to standard protocol (6:26 vs 12:59 min, p<0.001). Diagnostic confidence for DLR algorithm was not inferior to standard protocol. Conclusion: DLR applied to 1.5T MRI is a feasible method for lumbar spine imaging providing morphologic sequences with higher image quality and similar diagnostic confidence compared with standard protocol, enabling a remarkable time saving (up to 50%)
Radiomics applications in cardiac imaging: a comprehensive review
Radiomics is a new emerging field that includes extraction of metrics and quantification of so-called radiomic features from medical images. The growing importance of radiomics applied to oncology in improving diagnosis, cancer staging and grading, and improved personalized treatment, has been well established; yet, this new analysis technique has still few applications in cardiovascular imaging. Several studies have shown promising results describing how radiomics principles could improve the diagnostic accuracy of coronary computed tomography angiography (CCTA) and magnetic resonance imaging (MRI) in diagnosis, risk stratification, and follow-up of patients with coronary heart disease (CAD), ischemic heart disease (IHD), hypertrophic cardiomyopathy (HCM), hypertensive heart disease (HHD), and many other cardiovascular diseases. Such quantitative approach could be useful to overcome the main limitations of CCTA and MRI in the evaluation of cardiovascular diseases, such as readers' subjectiveness and lack of repeatability. Moreover, this new discipline could potentially overcome some technical problems, namely the need of contrast administration or invasive examinations. Despite such advantages, radiomics is still not applied in clinical routine, due to lack of standardized parameters acquisition, inconsistent radiomic methods, lack of external validation, and different knowledge and experience among the readers. The purpose of this manuscript is to provide a recent update on the status of radiomics clinical applications in cardiovascular imaging
Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols
Background: Patient body size represents the main determinant of parenchymal enhancement and by adjusting the contrast media (CM) dose to patient weight may be a more appropriate approach to avoid a patient over dosage of CM. To compare the performance of fixed-dose and lean body weight (LBW)-adapted contrast media dosing protocols, in terms of image quality and parenchymal enhancement. Results: One-hundred cancer patients undergoing multiphasic abdominal CT were prospectively enrolled in this multicentric study and randomly divided in two groups: patients in fixed-dose group (n = 50) received 120 mL of CM while in LBW group (n = 50) the amount of CM was computed according to the patient’s LBW. LBW protocol group received a significantly lower amount of CM (103.47 ± 17.65 mL vs. 120.00 ± 0.00 mL, p < 0.001). Arterial kidney signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and pancreatic CNR were significantly higher in LBW group (all p ≤ 0.004). LBW group provided significantly higher arterial liver, kidney, and pancreatic contrast enhancement index (CEI) and portal venous phase kidney CEI (all p ≤ 0.002). Significantly lower portal vein SNR and CNR were observed in LBW-Group (all p ≤ 0.020). Conclusions: LBW-adapted CM administration for abdominal CT reduces the volume of injected CM and improves both image quality and parenchymal enhancement
Chest CT texture-based radiomics analysis in differentiating COVID-19 from other interstitial pneumonia
Purpose
To evaluate the potential role of texture-based radiomics analysis in differentiating Coronavirus Disease-19 (COVID-19) pneumonia from pneumonia of other etiology on Chest CT.
Materials and methods
One hundred and twenty consecutive patients admitted to Emergency Department, from March 8, 2020, to April 25, 2020, with suspicious of COVID-19 that underwent Chest CT, were retrospectively analyzed. All patients presented CT findings indicative for interstitial pneumonia. Sixty patients with positive COVID-19 real-time reverse transcription polymerase chain reaction (RT-PCR) and 60 patients with negative COVID-19 RT-PCR were enrolled.
CT texture analysis (CTTA) was manually performed using dedicated software by two radiologists in consensus and textural features on filtered and unfiltered images were extracted as follows: mean intensity, standard deviation (SD), entropy, mean of positive pixels (MPP), skewness, and kurtosis. Nonparametric Mann–Whitney test assessed CTTA ability to differentiate positive from negative COVID-19 patients. Diagnostic criteria were obtained from receiver operating characteristic (ROC) curves.
Results
Unfiltered CTTA showed lower values of mean intensity, MPP, and kurtosis in COVID-19 positive patients compared to negative patients (p = 0.041, 0.004, and 0.002, respectively). On filtered images, fine and medium texture scales were significant differentiators; fine texture scale being most significant where COVID-19 positive patients had lower SD (p = 0.004) and MPP (p = 0.004) compared to COVID-19 negative patients. A combination of the significant texture features could identify the patients with positive COVID-19 from negative COVID-19 with a sensitivity of 60% and specificity of 80% (p = 0.001).
Conclusions
Preliminary evaluation suggests potential role of CTTA in distinguishing COVID-19 pneumonia from other interstitial pneumonia on Chest CT
Typical and atypical COVID-19 computed tomography findings
In December 2019 a novel coronavirus, named severe acute respiratory syndrome coronavirus 2 was identified and the disease associated was named coronavirus disease 2019 (COVID-19). Fever, cough, myalgia, fatigue associated to dyspnea represent most common clinical symptoms of the disease. The reference standard for diagnosis of severe acute respiratory syndrome coronavirus 2 infection is real time reverse-transcription polymerase chain reaction test applied on respiratory tract specimens. Despite of lower specificity, chest computed tomography (CT), as reported in manifold scientific studies, showed high sensitivity, therefore it may help in the early detection, management and follow-up of COVID-19 pneumonia. Patients affected by COVID-19 pneumonia usually showed on chest CT some typical features, such as: Bilateral ground glass opacities characterized by multilobe involvement with posterior and peripheral distribution; parenchymal consolidations with or without air bronchogram; interlobular septal thickening; crazy paving pattern, represented by interlobular and intralobular septal thickening surrounded by ground-glass opacities; subsegmental pulmonary vessels enlargement (> 3 mm). Halo sign, reversed halo sign, cavitation and pleural or pericardial effusion represent some of atypical findings of COVID-19 pneumonia. On the other hand lymphadenopathy's and bronchiectasis' frequency is unclear, indeed conflicting data emerged in literature. Radiologists play a key role in recognition of high suspicious findings of COVID-19 on chest CT, both typical and atypical ones. Thus, the aim of this review is to illustrate typical and atypical CT findings of COVID-19
How young radiologists use contrast media and manage adverse reactions: an international survey
Objectives: To collect real-world data about the knowledge and self-perception of young radiologists concerning the use of contrast media (CM) and the management of adverse drug reactions (ADR). Methods: A survey (29 questions) was distributed to residents and board-certified radiologists younger than 40 years to investigate the current international situation in young radiology community regarding CM and ADRs. Descriptive statistics analysis was performed. Results: Out of 454 respondents from 48 countries (mean age: 31.7 ± 4 years, range 25–39), 271 (59.7%) were radiology residents and 183 (40.3%) were board-certified radiologists. The majority (349, 76.5%) felt they were adequately informed regarding the use of CM. However, only 141 (31.1%) received specific training on the use of CM and 82 (18.1%) about management ADR during their residency. Although 266 (58.6%) knew safety protocols for handling ADR, 69.6% (316) lacked confidence in their ability to manage CM-induced ADRs and 95.8% (435) expressed a desire to enhance their understanding of CM use and handling of CM-induced ADRs. Nearly 300 respondents (297; 65.4%) were aware of the benefits of contrast-enhanced ultrasound, but 249 (54.8%) of participants did not perform it. The preferred CM injection strategy in CT parenchymal examination and CT angiography examination was based on patient’s lean body weight in 318 (70.0%) and 160 (35.2%), a predeterminate fixed amount in 79 (17.4%) and 116 (25.6%), iodine delivery rate in 26 (5.7%) and 122 (26.9%), and scan time in 31 (6.8%) and 56 (12.3%), respectively. Conclusion: Training in CM use and management ADR should be implemented in the training of radiology residents. Critical relevance statement: We highlight the need for improvement in the education of young radiologists regarding contrast media; more attention from residency programs and scientific societies should be focused on training about contrast media use and the management of adverse drug reactions. Key points: • This survey investigated training of young radiologists about use of contrast media and management adverse reactions. • Most young radiologists claimed they did not receive dedicated training. • An extreme heterogeneity of responses was observed about contrast media indications/contraindications and injection strategy. Graphical Abstract: (Figure presented.
Why Should We Preserve Fishless High Mountain Lakes?
High mountain lakes are originally fishless, although many have had introductions of non-native fish species, predominantly trout, and recently also minnows introduced by fishermen that use them as live bait. The extent of these introductions is general and substantial often involving many lakes over mountain ranges. Predation on native fauna by introduced fish involves profound ecological changes since fish occupy a higher trophic level that was previously inexistent. Fish predation produces a drastic reduction or elimination of autochthonous animal groups, such as amphibians and large macroinvertebrates in the littoral, and crustaceans in the plankton. These strong effects raise concerns for the conservation of high mountain lakes. In terms of individual species, those adapted to live in larger lakes have suffered a higher decrease in the size of their metapopulation. This ecological problem is discussed from a European perspective providing examples from two study areas: the Pyrenees and the Western Italian Alps. Species-specific studies are urgently needed to evaluate the conservation status of the more impacted species, together with conservation measures at continental and regional scales, through regulation, and at local scale, through restoration actions, aimed to stop further invasive species expansions and to restore the present situation. At different high mountain areas of the world, there have been restoration projects aiming to return lakes to their native fish-free status. In these areas autochthonous species that disappeared with the introduction of fish are progressively recovering their initial distribution when nearby fish-free lakes and ponds are available
- …