31 research outputs found

    Demonstration of a Transportable Fabry–Pérot Refractometer by a Ring-Type Comparison of Dead-Weight Pressure Balances at Four European National Metrology Institutes

    Get PDF
    Fabry–Pérot-based refractometry has demonstrated the ability to assess gas pressure with high accuracy and has been prophesized to be able to realize the SI unit for pressure, the pascal, based on quantum calculations of the molar polarizabilities of gases. So far, the technology has mostly been limited to well-controlled laboratories. However, recently, an easy-to-use transportable refractometer has been constructed. Although its performance has previously been assessed under well-controlled laboratory conditions, to assess its ability to serve as an actually transportable system, a ring-type comparison addressing various well-characterized pressure balances in the 10–90 kPa range at several European national metrology institutes is presented in this work. It was found that the transportable refractometer is capable of being transported and swiftly set up to be operational with retained performance in a variety of environments. The system could also verify that the pressure balances used within the ring-type comparison agree with each other. These results constitute an important step toward broadening the application areas of FP-based refractometry technology and bringing it within reach of various types of stakeholders, not least within industry

    The mechanics of adhesion polymers and their role in bacterial attachment

    No full text
    Bacterial resistance to antibiotics is increasing at a high rate in both developing and developed countries. To circumvent the problem of drug-resistant bacterial pathogens, we need to develop new effective methods, substances, and materials that can disarm and prevent them from causing infections. However, to do this we first need to find new possible targets in bacteria to approach and novel strategies to apply.Escherichia coli (E. coli) bacteria is a normal member of the intestinal microflora of humans and mammals, but frequently cause diverse intestinal and external diseases by means of virulence factors, which leads to hundreds of million sick people each year with a high mortality rate. An E. coli bacterial infection starts with adhesion to a host cell using cell surface expressed adhesion polymers, called adhesion pili. Depending on the local environment different types of pili are expressed by the bacteria. For example, bacteria found in the gastrointestinal tract commonly express different pili in comparison to those found in the urinary tract and respiratory tract. These pili, which are vital for bacterial adhesion, thereby serve as a new possible approach in the fight against bacterial infections by targeting and disabling these structures using novel chemicals. However, in order to develop such chemicals, better understanding of these pili is needed.Optical tweezers (OT) can measure and apply forces up to a few hundred pN with sub-pN force resolution and have shown to be an excellent tool for investigating mechanical properties of adhesion pili. It has been found that pili expressed by E. coli have a unique and complex force-extension response that is assumed to be important for the ability of bacteria to initiate and maintain attachment to the host cells. However, their mechanical functions and the advantage of specific mechanical functions, especially in the initial attachment process, have not yet been fully understood.In this work, a detailed description of the pili mechanics and their role during cell adhesion is presented. By using results from optical tweezers force spectroscopy experiments in combination with physical modeling and numerical simulations, we investigated how pili can act as “shock absorbers” through uncoiling and thereby lower the fluid force acting on a bacterium. Our result demonstrate that the dynamic uncoiling capability of the helical part of the adhesion pili modulate the force to fit the optimal lifetime of its adhesin (the protein that binds to the receptor on the host cell), ensuring a high survival probability of the bond.iiiSince the attachment process is in proximity of a surface we also investigated the influence of tether properties and the importance of different surface corrections and additional force components to the Stokes drag force during simulations. The investigation showed that the surface corrections to the Stokes drag force and the Basset force cannot be neglected when simulating survival probability of a bond, since that can overestimate the probability by more than an order of magnitude.Finally, a theoretical and experimental framework for two separate methods was developed. The first method can detect the presence of pili on single cells using optical tweezers. We verified the method using silica microspheres coated with a polymer brush and E. coli bacteria expressing; no pili, P pili, and type 1 pili, respectively. The second method was based on digital holography microscopy. Using the diffraction of semi-transparent object such as red blood cells, we showed that this method can reconstruct the axial position and detect morphological changes of cells

    The mechanics of adhesion polymers and their role in bacterial attachment

    No full text
    Bacterial resistance to antibiotics is increasing at a high rate in both developing and developed countries. To circumvent the problem of drug-resistant bacterial pathogens, we need to develop new effective methods, substances, and materials that can disarm and prevent them from causing infections. However, to do this we first need to find new possible targets in bacteria to approach and novel strategies to apply.Escherichia coli (E. coli) bacteria is a normal member of the intestinal microflora of humans and mammals, but frequently cause diverse intestinal and external diseases by means of virulence factors, which leads to hundreds of million sick people each year with a high mortality rate. An E. coli bacterial infection starts with adhesion to a host cell using cell surface expressed adhesion polymers, called adhesion pili. Depending on the local environment different types of pili are expressed by the bacteria. For example, bacteria found in the gastrointestinal tract commonly express different pili in comparison to those found in the urinary tract and respiratory tract. These pili, which are vital for bacterial adhesion, thereby serve as a new possible approach in the fight against bacterial infections by targeting and disabling these structures using novel chemicals. However, in order to develop such chemicals, better understanding of these pili is needed.Optical tweezers (OT) can measure and apply forces up to a few hundred pN with sub-pN force resolution and have shown to be an excellent tool for investigating mechanical properties of adhesion pili. It has been found that pili expressed by E. coli have a unique and complex force-extension response that is assumed to be important for the ability of bacteria to initiate and maintain attachment to the host cells. However, their mechanical functions and the advantage of specific mechanical functions, especially in the initial attachment process, have not yet been fully understood.In this work, a detailed description of the pili mechanics and their role during cell adhesion is presented. By using results from optical tweezers force spectroscopy experiments in combination with physical modeling and numerical simulations, we investigated how pili can act as “shock absorbers” through uncoiling and thereby lower the fluid force acting on a bacterium. Our result demonstrate that the dynamic uncoiling capability of the helical part of the adhesion pili modulate the force to fit the optimal lifetime of its adhesin (the protein that binds to the receptor on the host cell), ensuring a high survival probability of the bond.iiiSince the attachment process is in proximity of a surface we also investigated the influence of tether properties and the importance of different surface corrections and additional force components to the Stokes drag force during simulations. The investigation showed that the surface corrections to the Stokes drag force and the Basset force cannot be neglected when simulating survival probability of a bond, since that can overestimate the probability by more than an order of magnitude.Finally, a theoretical and experimental framework for two separate methods was developed. The first method can detect the presence of pili on single cells using optical tweezers. We verified the method using silica microspheres coated with a polymer brush and E. coli bacteria expressing; no pili, P pili, and type 1 pili, respectively. The second method was based on digital holography microscopy. Using the diffraction of semi-transparent object such as red blood cells, we showed that this method can reconstruct the axial position and detect morphological changes of cells

    Invar-based refractometer for pressure assessments

    No full text
    Gas modulation refractometry (GAMOR) is a methodology that can mitigate fluctuations and drifts in refractometry. This can open up for the use of non-conventional cavity spacer materials. In this paper, we report a dual-cavity system based on Invar that shows better precision for assessment of pressure than a similar system based on Zerodur. This refractometer shows for empty cavity measurements, up to 10(4) s, a white noise response (for N-2) of 3 mPa s(1/2). At 4303 Pa, the system has a minimum Allan deviation of 0.34 mPa (0.08 ppm) and a long-term stability (24 h) of 0.7 mPa. This shows that the GAMOR methodology allows for the use of alternative cavity materials

    Recent advances in Fabry-Péro-based refractometry utilizing gas modulation for assessment of pressure

    No full text
    Gas modulation refractometry (GAMOR) is a methodology that can mitigate the influence of fluctuations and drifts in Fabry-Pérot cavity–based refractometry. This paper presents a thorough description of its principles, what it enables, and its applicability. An overview of the latest results is presented, including the realization of a system based upon a cavity spacer made of Invar that allows for detection of N2 with sub-ppm precision, and a characterization procedure that allows for assessment of N2 with an accuracy at low-ppm levels

    Fabry-Perot-cavity-based refractometry without influence of mirror penetration depth

    No full text
    Assessments of refractivity in a Fabry-Perot (FP) cavity by refractometry often encompass a step in which the penetration depth of the light into the mirrors is estimated to correct for the fraction of the cavity length into which no gas can penetrate. However, as it is currently carried out, this procedure is not always coherently performed. Here, we discuss a common pitfall that can be a reason for this and provide a recipe on how to perform FP-cavity-based refractometry without any influence of mirror penetration depth.Errata: C. Forssén, I. Silander, J. Zakrisson, M. Zelan, and O. Axner , "Retraction: “Fabry–Perot-cavity-based refractometry without influence of mirror penetration depth” [J. Vac. Sci. Technol. B 39, 065001 (2021)]", Journal of Vacuum Science &amp; Technology B 40, 037001 (2022) https://doi.org/10.1116/6.0001829</p

    The short-term performances of two independent gas modulated refractometers for pressure assessments

    No full text
    Refractometry is a powerful technique for pressure assessments that, due to the recent redefinition of the SI system, also offers a new route to realizing the SI unit of pressure, the Pascal. Gas modulation refractometry (GAMOR) is a methodology that has demonstrated an outstanding ability to mitigate the influences of drifts and fluctuations, leading to long-term precision in the 10−7 region. However, its short-term performance, which is of importance for a variety of applications, has not yet been scrutinized. To assess this, we investigated the short-term performance (in terms of precision) of two similar, but independent, dual Fabry–Perot cavity refractometers utilizing the GAMOR methodology. Both systems assessed the same pressure produced by a dead weight piston gauge. That way, their short-term responses were assessed without being compromised by any pressure fluctuations produced by the piston gauge or the gas delivery system. We found that the two refractometer systems have a significantly higher degree of concordance (in the 10−8 range at 1 s) than what either of them has with the piston gauge. This shows that the refractometry systems under scrutiny are capable of assessing rapidly varying pressures (with bandwidths up to 2 Hz) with precision in the 10−8 range
    corecore