5 research outputs found

    Evaluation of Magnetic Micro- and Nanoparticle Toxicity to Ocular Tissues

    Get PDF
    Purpose: Magnetic nanoparticles (MNPs) may be used for focal delivery of plasmids, drugs, cells, and other applications. Here we ask whether such particles are toxic to ocular structures. Methods: To evaluate the ocular toxicity of MNPs, we asked if either 50 nm or 4 mm magnetic particles affect intraocular pressure, corneal endothelial cell count, retinal morphology including both cell counts and glial activation, or photoreceptor function at different time points after injection. Sprague-Dawley rats (n = 44) were injected in the left eye with either 50 nm (3 ml, 1.65 mg) or 4 mm(3ml, 1.69 mg) magnetic particles, and an equal volume of PBS into the right eye. Electroretinograms (ERG) were used to determine if MNPs induce functional changes to the photoreceptor layers. Enucleated eyes were sectioned for histology and immunofluorescence. Results: Compared to control-injected eyes, MNPs did not alter IOP measurements. ERG amplitudes for a-waves were in the 100–250 mV range and b-waves were in the 500–600 mV range, with no significant differences between injected and noninjected eyes. Histological sectioning and immunofluorescence staining showed little difference in MNP-injected animals compared to control eyes. In contrast, at 1 week, corneal endothelial cell numbers were significantly lower in the 4 mm magnetic particle-injected eyes compared to either 50 nm MNP- or PBS-injected eyes. Furthermore, iron deposition was detected after 4 mm magnetic particle but not 50 nm MNP injection

    Attachment of water-soluble proteins to the surface of (magnetizable) phospholipid colloids via NeutrAvidin-derivatized phospholipids

    No full text
    The present work describes the incorporation of a functionalized phospholipid derivative into the phospholipid bilayer of both classical small unilamellar vesicles and recently developed magnetoliposomes, resulting in unique biocolloid structures onto which peripheral water-soluble enzymes can be immobilized on the surfaces. In the first part of this work, a synthesis protocol is outlined for a universal membrane anchor for water-soluble proteins. Dioleoylphosphatidylethanolamine-N-dodecanyl was used as the starting lipid molecule. After activation of the terminal -COOH group, alpha,omega-diamino-poly(ethylene glycol), used as a hydrophilic, flexible spacer arm, was coupled covalently. Subsequently, NeutrAvidin was bound, after blocking the free -NH2 groups with citraconic anhydride. In the second part, the resulting lipid-NeutrAvidin derivative was incorporated into small unilamellar vesicles comprised of dimyristoylphosphatidylglycerol. FPLC with Superdex 200 as the column matrix clearly showed that biotinylated alkaline phosphatase, which served as a representative model of water-soluble proteins, was attached to the vesicles. Furthermore, magnetoliposomes, constructed of the same type of phospholipid molecules, were presented as interesting colloids to assess the degree of enzyme immobilization in a rapid and elegant manner. Potential applications that can emerge from this study are briefly discussed. (C) 2002 Elsevier Science.245227428

    Preliminary biocompatibility investigation of magnetic albumin nanosphere designed as a potential versatile drug delivery system

    No full text
    Luciana Estevanato1, Débora Cintra1, Nayara Baldini1, Flávia Portilho1, Luzirlane Barbosa1, Olímpia Martins2, Bruno Lacava3, Ana Luisa Miranda-Vilela1, Antônio Cláudio Tedesco2, Sônia Báo1, Paulo C Morais4, Zulmira GM Lacava11Instituto de Ciências Biológicas, Universidade de Brasília, 2Departamento de Química, Laboratório de Fotobiologia e Fotomedicina, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, 3Instituto de Química, Universidade de Brasília, Brasília, 4Instituto de Física, Universidade de Brasília, Brasília, BrazilBackground: The magnetic albumin nanosphere (MAN), encapsulating maghemite nanoparticles, was designed as a magnetic drug delivery system (MDDS) able to perform a variety of biomedical applications. It is noteworthy that MAN was efficient in treating Ehrlich's tumors by the magnetohyperthermia procedure.Methods and materials: In this study, several nanotoxicity tests were systematically carried out in mice from 30 minutes until 30 days after MAN injection to investigate their biocompatibility status. Cytometry analysis, viability tests, micronucleus assay, and histological analysis were performed.Results: Cytometry analysis and viability tests revealed MAN promotes only slight and temporary alterations in the frequency of both leukocyte populations and viable peritoneal cells, respectively. Micronucleus assay showed absolutely no genotoxicity or cytotoxicity effects and histological analysis showed no alterations or even nanoparticle clusters in several investigated organs but, interestingly, revealed the presence of MAN clusters in the central nervous system (CNS).Conclusion: The results showed that MAN has desirable in vivo biocompatibility, presenting potential for use as a MDDS, especially in CNS disease therapy.Keywords: nanotoxicity, nanoparticle, genotoxicity, cytotoxicity, brai

    Multifunctional magnetic iron oxide nanoparticles: diverse synthetic approaches, surface modifications, cytotoxicity towards biomedical and industrial applications

    No full text
    corecore