38 research outputs found

    Synthesis and Properties of High Tilted Antiferroelectric Esters with Partially Fluorinated Alkoxyalkoxy Terminal Chains

    Full text link
    Novel chiral esters with partially fluorinated alkoxyalkoxy terminal chains are described. Their phase transition temperatures, enthalpies, and electrooptical properties are reported. A helical pitch in pure compounds and their mixtures based on selective reflection of light is also characterized

    Photoacclimation in Dunaliella tertiolecta reveals a unique NPQ pattern upon exposure to irradiance

    Get PDF
    Highly time-resolved photoacclimation patterns of the chlorophyte microalga Dunaliella tertiolecta during exposure to an off–on–off (block) light pattern of saturating photon flux, and to a regime of consecutive increasing light intensities are presented. Non-photochemical quenching (NPQ) mechanisms unexpectedly responded with an initial decrease during dark–light transitions. NPQ values started to rise after light exposure of approximately 4 min. State-transitions, measured as a change of PSII:PSI fluorescence emission at 77 K, did not contribute to early NPQ oscillations. Addition of the uncoupler CCCP, however, caused a rapid increase in fluorescence and showed the significance of qE for NPQ. Partitioning of the quantum efficiencies showed that constitutive NPQ was (a) higher than qE-driven NPQ and (b) responded to light treatment within seconds, suggesting an active role of constitutive NPQ in variable energy dissipation, although it is thought to contribute statically to NPQ. The PSII connectivity parameter p correlated well with F′, Fm′ and NPQ during the early phase of the dark–light transients in sub-saturating light, suggesting a plastic energy distribution pattern within energetically connected PSII centres. In consecutive increasing photon flux experiments, correlations were weaker during the second light increment. Changes in connectivity can present an early photoresponse that are reflected in fluorescence signals and NPQ and might be responsive to the short-term acclimation state, and/or to the actinic photon flux

    Evaluation of the strength of glass fiber-reinforced composite posts placed in root canals in different quantitative configurations and exposed to crushing forces

    No full text
    The strength of fiber glass reinforced composite (FRC) posts, inserted in root canals in different quantitative configurations and exposed to crushing forces, assuming no adhesive connection in the coronal area, was evaluated. Three systems of FRC posts and one core build-up material were used in this study. The test was performed on FRC posts in three different quantitative configurations. The posts were cemented in the root canals in 36 premolars. 21 teeth were exposed to vertical forces, while 15 teeth were exposed to forces at an angle of 45° with respect to the vertical axis. After the strength tests, each sample was analyzed in the micro computed tomography (micro-CT) in order to verify that the forces do not cause defects in the areas of the adhesive connection. The largest values of the crushing forces (over 1000 N), which caused the destruction of posts were observed in case of Ena Post used in the form of single post with the greatest diameter or composed of three posts with different diameter, as well as for triple Postec Plus posts. In the case of the force acting at the angle of 45° no statistically significant differences were observed for all post configurations. No defects were found in micro-CT images of the analyzed areas of adhesive connections. The obtained results do not confirm the concept that the use of more than one post per canal may significantly improve the clinical effectiveness of FRC posts – the differences in the values of the destructive force per one post and multiple posts were not statistically significant.Badano wytrzymałość na zgniatanie wkładów kompozytowych zawierających włókno szklane (FRC) umieszczonych w kanałach korzeniowych w różnych konfiguracjach ilościowych, przy założeniu braku połączenia adhezyjnego w obszarze koronowym. Ocenie poddano trzy systemy wkładów FRC oraz polimerowy materiał typu core build-up. Wkłady w trzech różnych wariantach ilościowych zacementowano w kanałach 36 zębów przedtrzonowych. 21 zębów poddano działaniu siły zgniatającej w kierunku pionowym, a 15 – działaniu siły pod kątem 45° w stosunku do osi pionowej. Po przeprowadzeniu testów wytrzymałościowych każdą próbkę analizowano za pomocą mikrotomografu komputerowego w celu sprawdzenia, czy połączenie adhezyjne w kanale korzeniowym zostało zerwane. Największe wartości (powyżej 1000 N) użytej siły zgniatającej, powodującej zniszczenie wkładów, odnosiły się do Ena Post stosowanego w postaci pojedynczego wkładu o największej średnicy lub złożonego z trzech o różnej średnicy oraz do Postec Plus w postaci wkładu potrójnego. W wypadku działania siły zgniatającej pod kątem 45° w stosunku do osi pionowej nie stwierdzono różnic statystycznie istotnych między wartościami średnimi tej siły w odniesieniu do wszystkich konfiguracji wkładów. Na podstawie obrazów uzyskanych w mikroobrazowej tomografii komputerowej (micro-CT) nie stwierdzono zerwania lub uszkodzenia połączenia adhezyjnego w analizowanych obszarach. Uzyskane wyniki świadczą, że zastosowanie w kanale korzeniowym więcej niż jednego kompozytowego wkładu zawierającego włókna szklane nie zwiększa w istotnym stopniu efektywności wypełnienia; różnice w wartościach siły niszczącej pojedynczy wkład i wkład wielokrotny nie były istotne statystycznie

    Wytrzymałość na zgniatanie wkładów kompozytowych wzmocnionych włóknem szklanym umieszczonych w kanałach korzeniowych w różnej konfiguracji ilościowej

    No full text
    The strength of fiber glass reinforced composite (FRC) posts, inserted in root canals in different quantitative configurations and exposed to crushing forces, assuming no adhesive connection in the coronal area, was evaluated. Three systems of FRC posts and one core build-up material were used in this study. The test was performed on FRC posts in three different quantitative configurations. The posts were cemented in the root canals in 36 premolars. 21 teeth were exposed to vertical forces, while 15 teeth were exposed to forces at an angle of 45° with respect to the vertical axis. After the strength tests, each sample was analyzed in the micro computed tomography (micro-CT) in order to verify that the forces do not cause defects in the areas of the adhesive connection. The largest values of the crushing forces (over 1000 N), which caused the destruction of posts were observed in case of Ena Post used in the form of single post with the greatest diameter or composed of three posts with different diameter, as well as for triple Postec Plus posts. In the case of the force acting at the angle of 45° no statistically significant differences were observed for all post configurations. No defects were found in micro-CT images of the analyzed areas of adhesive connections. The obtained results do not confirm the concept that the use of more than one post per canal may significantly improve the clinical effectiveness of FRC posts – the differences in the values of the destructive force per one post and multiple posts were not statistically significant.Badano wytrzymałość na zgniatanie wkładów kompozytowych zawierających włókno szklane (FRC) umieszczonych w kanałach korzeniowych w różnych konfiguracjach ilościowych, przy założeniu braku połączenia adhezyjnego w obszarze koronowym. Ocenie poddano trzy systemy wkładów FRC oraz polimerowy materiał typu core build-up. Wkłady w trzech różnych wariantach ilościowych zacementowano w kanałach 36 zębów przedtrzonowych. 21 zębów poddano działaniu siły zgniatającej w kierunku pionowym, a 15 – działaniu siły pod kątem 45° w stosunku do osi pionowej. Po przeprowadzeniu testów wytrzymałościowych każdą próbkę analizowano za pomocą mikrotomografu komputerowego w celu sprawdzenia, czy połączenie adhezyjne w kanale korzeniowym zostało zerwane. Największe wartości (powyżej 1000 N) użytej siły zgniatającej, powodującej zniszczenie wkładów, odnosiły się do Ena Post stosowanego w postaci pojedynczego wkładu o największej średnicy lub złożonego z trzech o różnej średnicy oraz do Postec Plus w postaci wkładu potrójnego. W wypadku działania siły zgniatającej pod kątem 45° w stosunku do osi pionowej nie stwierdzono różnic statystycznie istotnych między wartościami średnimi tej siły w odniesieniu do wszystkich konfiguracji wkładów. Na podstawie obrazów uzyskanych w mikroobrazowej tomografii komputerowej (micro-CT) nie stwierdzono zerwania lub uszkodzenia połączenia adhezyjnego w analizowanych obszarach. Uzyskane wyniki świadczą, że zastosowanie w kanale korzeniowym więcej niż jednego kompozytowego wkładu zawierającego włókna szklane nie zwiększa w istotnym stopniu efektywności wypełnienia; różnice w wartościach siły niszczącej pojedynczy wkład i wkład wielokrotny nie były istotne statystycznie

    Ocena wytrzymałości połączenia wybranych cementów polimerowych z zębiną kanałową i wkładem wzmocnionym włóknem szklanym

    No full text
    The aim of the study was to assess the value of the breaking force of the bonding between selected polymer cements, root dentin and fiber reinforced composite (FRC) posts. Five resin based luting cements were selected for use in the study. Tests were performed on a total of 30 teeth, which were divided into two groups. Fifteen teeth were installed vertically and 15 with an angle of 45°. All samples were exposed to crushing forces in an Instron 4411 device. After the strength tests, each sample was analyzed by micro-CT (micro computed tomography) in order to verify that the forces did not cause defects in the areas of the adhesive connection. The differences observed in the present study only involved the posts that failed at different values of the acting forces – in the case of the vertical sample, x =532.5 N and in the case with an angle of 45°, x = 117.9 N. For the micro-CT images, there were no defects in the analyzed areas of the adhesive connections. Under the conditions of the current study, all selected polymer cements showed the required level of bonding.Oceniono wytrzymałość połączenia cementów polimerowych z zębiną kanałową i wkładem wzmocnionym włóknem szklanym. Zbadano pięć rodzajów polimerowych cementów stosowanych do stałego osadzania wkładów. Przeprowadzono test wytrzymałościowy 30 próbek zębów, podzielonych na dwie grupy: 15 zębów osadzonych pionowo i 15 zębów osadzonych pod kątem 45°. Wszystkie próbki poddano działaniu siły zgniatającej za pomocą urządzenia Instron 4411, a następnie każdą próbkę analizowano metodą mikroobrazowej tomografii komputerowej (mikro-CT) w celu sprawdzenia stanu połączenia między zębiną i cementem oraz wkładem i cementem. W żadnym wypadku nie stwierdzono zerwania połączenia. Zaobserwowano jedynie różnice wartości siły uszkadzającej wkład. W wypadku próbki ustawionej pionowo wyniosła ona średnio 532,5 N, a próbki ustawionej pod kątem – 117,9 N. W obszarach analizowanych metodą mikro-CT nie stwierdzono zerwania połączenia. W warunkach przeprowadzonego badania wszystkie wybrane cementy polimerowe wykazały oczekiwany poziom połączenia

    A Study Of A Binary Liquid-Crystalline Mixtures With The Wide Antiferroelectric Phase

    No full text
    Binary mixtures of fluorinated materials having broad antiferroelectric phase have been prepared. A set of phase parameters (phase transition temperatures and enthalpies, the spontaneous polarization and the tilt angle) of pure antiferroelectric components and mixtures prepared using them have been studied. Electrooptical investigations of obtained mixtures have been conducted. An influence of mole mixing ratio of two components on evolution of electrooptical switching from tristable through V-shaped to W-shaped characteristics has been observed. The thresholdless switching of a mixture with specific mixing ratio has been ascribed as the result of the formation of frustrated phase in the medium. Copyright © Taylor & Francis Group, LLC
    corecore