26 research outputs found

    Long-term observation of fibrillation cycle length in patients under angiotensin II receptor blocker therapy for chronic atrial fibrillation

    Get PDF
    AbstractIntroductionThe long-term effect of angiotensin II receptor blockers (ARBs) on atrial fibrillation (AF) is unclear. In this study, we evaluated the change in the fibrillation cycle length (FCL) in patients under long-term ARB therapy for chronic AF.Methods and resultsThe study population consisted of 25 chronic AF patients who were prescribed the same medication for more than 6 years and in whom specific ECG recording for FCL evaluation could be performed before and after the 6-year observation period. The patients were divided into 2 groups: those with and without ARB (ARB group and non-ARB group and n=15 and 10, respectively). FCL was calculated by the spectral analysis of the fibrillation waves in the surface ECG. There was no significant difference in the clinical characteristics between the 2 groups. In the ARB group, the mean FCL was prolonged from 154±20ms to 187±37ms (p=0.005), whereas it remained unchanged in the non-ARB group (150±12ms vs. 149±10ms). In the comparison between patients with and those without FCL prolongation (>30ms; n=6 and 19, respectively), a significant difference was observed only in those prescribed ARBs.ConclusionIn cases of chronic AF, FCL might be prolonged under long-term ARB treatment

    Evaluation of the impact of atrial fibrillation on rehospitalization events in heart failure patients in recent years

    Get PDF
    SummaryBackgroundAlthough we have previously reported that the presence of paroxysmal atrial fibrillation (AF) is an independent risk factor for rehospitalization in patients with congestive heart failure (CHF) in a population from 1996 to 2002, the impact of AF configuration as a risk factor in a more recent population remains to be clarified.Methods and results319 patients with CHF admitted to our institute in 2006–2007 were retrospectively evaluated. The patients were divided into 3 groups in accordance with their basic cardiac rhythm, i.e. sinus rhythm (n=210), chronic AF (n=68), and paroxysmal AF (n=41). During the follow-up period of 19±17months, there was no significant difference in mortality or rehospitalization events among the 3 groups (p=0.542). In the multivariate analysis, no administration of β-blockers was the only independent risk factor for rehospitalization due to CHF exacerbation.ConclusionsThe clinical impact of AF configuration as a risk factor of rehospitalization due to CHF exacerbation was considered to be decreased in recent years

    Association of Pain History and Current Pain With Sagittal Spinal Alignment and Muscle Stiffness and Muscle Mass of the Back Muscles in Middle-aged and Elderly Women

    Get PDF
    [Study Design] A cross-sectional study. [Objective] To investigate the association of low back pain history (LBPH) and LBP with sagittal spinal alignment, stiffness assessed using ultrasonic shear wave elastography, and mass of the back muscle in community-dwelling middle-aged and elderly women. [Summary of Background Data] The association of LBPH and LBP with sagittal spinal alignment, stiffness, and mass of the back muscles remains unclear in middle-aged and elderly women. [Participants and Methods] The study comprised 19 asymptomatic middle-aged and elderly women [control (CTR) group], 16 middle-aged and elderly women with LBPH (LBPH group), and 23 middle-aged and elderly women with LBP (LBP group). Sagittal spinal alignment in the standing and prone positions (kyphosis angle in the thoracic spine, lordosis angle in the lumbar spine, and anterior inclination angle in the sacrum) was measured using a Spinal Mouse. The stiffness of the back muscles (lumbar erector spinae and multifidus) in the prone position was measured using ultrasonic shear wave elastography. The mass of the back muscles (thoracic and lumbar erector spinae, lumbar multifidus, and quadratus lumborum) was also measured. [Results] Multiple logistic regression analysis with a forward selection method showed that the stiffness of the lumbar multifidus muscle was a significant and independent factor of LBPH. The stiffness of the lumbar multifidus muscle was significantly higher in the LBPH group than in the CTR group. Multiple logistic regression analysis also indicated that lumbar lordosis angle in the standing position was a significant and independent factor of LBP. The lumbar lordosis angle was significantly smaller in the LBP group than in the CTR group. [Conclusions] Our results suggest that LBPH is associated with increased stiffness of the lumbar multifidus muscle in the prone position, and that LBP is associated with the decreased lumbar lordosis in the standing position in community-dwelling middle-aged and elderly women

    An 8-Tap CMOS Lock-In Pixel Image Sensor for Short-Pulse Time-of-Flight Measurements

    No full text
    An 8-tap CMOS lock-in pixel image sensor that has seven carrier-capturing and a draining time window was developed for short-pulse time-of-flight (TOF) measurements. The proposed pixel for the short-pulse TOF measurements has seven consecutive time-gating windows, each of which has the width of 6 ns, which is advantageous for high-resolution range imaging, particularly for relatively longer distances (>5 m) and under high ambient light operations. In order to enhance the depth resolution, a technique for the depth-adaptive time-gating-number assignment (DATA) for the short-pulse TOF measurement is proposed. A prototype of the 8-tap CMOS lock-in pixel image sensor is implemented with a 1POLY 4METAL 0.11-μm CIS process. The maximum non-linearity error of 1.56%FS for the range of 1–6.4 m and the depth resolution of 6.4 mm was obtained at 6.2 m using the DATA technique

    Isolation of a major genetic interaction associated with an extreme phenotype using assorted F2 populations in rice

    Get PDF
    Detection of quantitative trait loci (QTLs) is dependent on the materials used in the analysis, as different combinations of parental materials may lead to different outcomes in QTLs for the same trait. On the other hand, an extreme phenotype associated with a given trait implies the potential involvement of a particular allele in various allelic interactions. A genetic factor associated with such an extreme phenotype may frequently be identified from various genetic populations consisting of different parental combinations. In this study, we attempted to uncover the genetic factor associated with extremely early heading date in rice, using various F2 populations. Heading date in rice has been characterized by at least 19 QTLs, from which 12 genes have been identified. A58, a rice strain with an extremely early heading date, is adapted to Hokkaido, the northernmost limit of rice cultivation. Six F2 populations derived from crosses of A58 with six other strains displayed a range of heading dates. Genotyping using 19 QTL markers indicated that the A58 allele of the Ghd7 locus was present in most F2 individuals exhibiting extremely early heading dates. This analysis also demonstrated that when the wild-type Ehd1 allele was present, the Ghd7 allele from A58 accelerated floral induction. The results of this study demonstrate that assorted F2 populations are valuable materials for comprehensive genotyping to explore major genetic factors for extreme phenotypes, and that this methodology is broadly applicable to other unknown traits

    Almost optimal measurement scheduling of molecular Hamiltonian via finite projective plane

    No full text
    We propose an efficient and almost optimal scheme for measuring molecular Hamiltonians in quantum chemistry on quantum computers, which requires 2N^{2} distinct measurements in the leading order with N being the number of molecular orbitals. It achieves the state-of-the-art by improving a previous proposal by Bonet-Monroig et al. [Phys. Rev. X 10, 031064 (2020)10.1103/PhysRevX.10.031064], which exhibits 10/3N^{2} scaling in the leading order. We develop a method based on a finite projective plane to construct sets of simultaneously measurable operators contained in molecular Hamiltonians. Each measurement only requires a depth-O(N) circuit consisting of O(N^{2}) one- and two-qubit gates under the Jordan-Wigner and parity mapping, assuming the linear connectivity of qubits on quantum hardwares. We perform numerical simulation of our method for molecular Hamiltonians of hydrogen chains. We count the number of sets of simultaneously measurable operators generated by our method and estimate the number of measurement shots required to achieve the small standard deviation of the energy expectation value for precise quantum chemistry calculations. Because evaluating expectation values of molecular Hamiltonians is one of the major bottlenecks in the applications of quantum devices to quantum chemistry, our finding is expected to accelerate such applications

    A Time-of-Flight Image Sensor Using 8-Tap P-N Junction Demodulator Pixels

    No full text
    This paper presents a time-of-flight image sensor based on 8-Tap P-N junction demodulator (PND) pixels, which is designed for hybrid-type short-pulse (SP)-based ToF measurements under strong ambient light. The 8-tap demodulator implemented with multiple p-n junctions used for modulating the electric potential to transfer photoelectrons to eight charge-sensing nodes and charge drains has an advantage of high-speed demodulation in large photosensitive areas. The ToF image sensor implemented using 0.11 µm CIS technology, consisting of an 120 (H) × 60 (V) image array of the 8-tap PND pixels, successfully works with eight consecutive time-gating windows with the gating width of 10 ns and demonstrates for the first time that long-range (>10 m) ToF measurements under high ambient light are realized using single-frame signals only, which is essential for motion-artifact-free ToF measurements. This paper also presents an improved depth-adaptive time-gating-number assignment (DATA) technique for extending the depth range while having ambient-light canceling capability and a nonlinearity error correction technique. By applying these techniques to the implemented image sensor chip, hybrid-type single-frame ToF measurements with depth precision of maximally 16.4 cm (1.4% of the maximum range) and the maximum non-linearity error of 0.6% for the full-scale depth range of 1.0–11.5 m and operations under direct-sunlight-level ambient light (80 klux) have been realized. The depth linearity achieved in this work is 2.5 times better than that of the state-of-the-art 4-tap hybrid-type ToF image sensor
    corecore