61 research outputs found

    Salivary DNA methylation panel to diagnose HPV-positive and HPV-negative head and neck cancers

    Get PDF
    Background Head and neck squamous cell carcinoma (HNSCC) is a heterogeneous group of tumours with a typical 5 year survival rate of INK4a, TIMP3, PCQAP/MED15) will allow us to diagnose HNSCC patients from a normal healthy control group as well as to discriminate between Human Papillomavirus (HPV)-positive and HPV-negative patients. Methods Methylation-specific PCR (MSP) was used to determine the methylation levels of RASSF1α, p16INK4a, TIMP3 and PCQAP/MED15 in DNA isolated from saliva. Statistical analysis was carried out using non-parametric Mann-Whitney’s U-test for individually methylated genes. A logistic regression analysis was carried out to determine the assay sensitivity when combing the five genes. Further, a five-fold cross-validation with a bootstrap procedure was carried out to determine how well the panel will perform in a real clinical scenario. Results Salivary DNA methylation levels were not affected by age. Salivary DNA methylation levels for RASSF1α, p16INK4a, TIMP3 and PCQAP/MED15 were higher in HPV-negative HNSCC patients (n = 88) compared with a normal healthy control group (n = 122) (sensitivity of 71 % and specificity of 80 %). Conversely, DNA methylation levels for these genes were lower in HPV-positive HNSCC patients (n = 45) compared with a normal healthy control group (sensitivity of 80 % and specificity of 74 %), consistent with the proposed aetiology of HPV-positive HNSCCs. Conclusions Salivary DNA tumour-suppressor methylation gene panel has the potential to detect early-stage tumours in HPV-negative HNSCC patients. HPV infection was found to deregulate the methylation levels in HPV-positive HNSCC patients. Large-scale double-blinded clinical trials are crucial before this panel can potentially be integrated into a clinical setting

    第860回千葉医学会例会・第16回千葉大学放射線医学教室例会

    Get PDF
    Methylation pattern in tumours and normal tissues. The methylation signature of RASSF1Îą, TIMP3 and PCQAP in HNSCC and normal tissues from The Cancer Genome Atlas (TCGA) database. (DOCX 91 kb

    >

    No full text

    Within-day baseline variation in salivary biomarkers in healthy men

    No full text
    Saliva is an easily accessible sample and offers practical and noninvasive biomarker solutions as an alternative to blood and urine-based diagnostics. Saliva contains a plethora of biomolecules such as nucleic acids, hormones, proteins, and electrolytes. On the other hand, little is known on the extent to which the biomolecules in saliva vary over time within a given person. This baseline information is crucial for future development of robust saliva-based diagnostics. We have collected unstimulated whole mouth saliva from 20 healthy young men at four times during the day, including before and after a meal. We measured the salivary cortisol, testosterone, C-reactive protein (CRP), stability of genomic DNA (gDNA) and DNA methylation levels of APC, P16, and PCQAP in these samples. We found that the salivary CRP, DNA methylation, and CD44 gDNA levels did not vary significantly across four time points (p > 0.05) while the salivary cortisol and testosterone levels significantly varied from the morning collection to the afternoon collection (p < 0.05). Furthermore, salivary cortisol levels were significantly affected by eating (p < 0.05). Our study offers a within-person baseline temporal assessment of several clinically relevant biomolecules and diagnostics, and suggests that salivary cortisol and testosterone levels vary over time in a given day whereas CRP and DNA methylation of tumor suppressor genes and CD44 amplification are stable throughout the day. Future research and clinical applications of salivary biomarkers and diagnostics should take into consideration their temporal variations

    Effects of Prebiotics on Antioxidant Activity of Goat Milk Fermented by Lactobacillus plantarum L60

    No full text
    The production of functional fermented goat milk with synbiotic have attracted widespread attention recently with the purpose of promoting health. The aim of present study was to investigate the effects of several prebiotics (inulin, fructo-oligosaccharide, galacto-oligosaccharide and xylo-oligosaccharide) on antioxidant activity and promote the development of functional goat milk. All the prebiotics exhibited the potential of enhancing the antioxidant activity of fermented goat milk, especially inulin and fructo-oligosaccharide showed better promotive effects. The optimum additions of inulin, xylo-oligosaccharide, galacto-oligosaccharide and fructo-oligosaccharide obtained were 0.6%, 0.6%, 0.6% and 0.4%, respectively. The DPPH radical scavenging rates reached to 75.52%, 74.12%, 69.41%, 80.28%, respectively, and the scavenging rates of superoxide radical were 21.09%, 18.20%, 27.61% and 29.92%, respectively, which were all higher than the control. This paper provides theoretical basis for the development of the functional goat milk

    A pilot study to profile salivary angiogenic factors to detect head and neck cancers

    No full text
    Background Early diagnosis of head and neck squamous cell carcinoma (HNSCCs) is an appealing way to increase survival rates in these patients as well as to improve quality of life post-surgery. Angiogenesis is a hallmark of tumor initiation and progression. We have investigated a panel of angiogenic factors in saliva samples collected from HNSCC patients and controls using the Bio-Plex ProTM assays. Methods We have identified a panel of five angiogenic proteins (sEGFR, HGF, sHER2, sIL-6Ra and PECAM-1) to be elevated in the saliva samples collected from HNSCC patients (n = 58) compared to a control cohort (n = 8 smokers and n = 30 non-smokers). Results High positive correlations were observed between the following sets of salivary proteins; sEGFR:sHER2, sEGFR:HGF, sEGFR:sIL-6Rα, sHER2:HGF and sHER2:sIL6Ra. A moderate positive correlation was seen between FGF-basic and sEGFR. Conclusion We have shown that angiogenic factor levels in saliva can be used as a potential diagnostic biomarker panel in HNSCC

    Development of paper-based analytical devices for minimizing the viscosity effect in human saliva

    No full text
    Rationale: Saliva as a sample matrix is rapidly gaining interest for disease diagnosis and point-of-care assays because it is easy to collect (non-invasive) and contains many health-related biomarkers. However, saliva poses particular problems relative to more common urine and blood matrices, which includes low analyte concentrations, lack of understanding of biomolecule transportation and inherent viscosity variability in human samples. While several studies have sought to improve assay sensitivity, few have addressed sample viscosity specifically. The goal of this study is to minimize the effect of sample viscosity on paper-based analytical devices (PADs) for the measurement of pH and nitrite in human saliva. Methods: PADs were used to measure salivary pH from 5.0 to 10.0 with a universal indicator consisting of chlorophenol red, phenol red and phenolphthalein. Nitrite determination was performed using the Griess reaction. Artificial saliva with viscosity values between 1.54 and 5.10 mPa∙s was tested on the proposed PAD. To ensure the proposed PADs can be tailored for use in-field analysis, the devices were shipped to Australia and tested with human specimens. Results: Initial experiments showed that viscosity had a significant impact on the calibration curve for nitrite; however, a more consistent curve could be generated when buffer was added after the sample, irrespective of sample viscosity. The linear range for nitrite detection was 0.1 to 2.4 mg/dL using the improved method. The nitrite measurement in artificial saliva also showed a good correlation with the standard spectrophotometry method (p=0.8484, paired sample t-test, n=20). Measured pH values from samples with varying viscosities correlated well with the results from our pH meter. Conclusions: The inherent variation of salivary viscosity that impacts nitrite and pH results can be addressed using a simple washing step on the PAD without the need for complex procedures

    A multimarker approach to diagnose and stratify heart failure

    No full text
    Background We have previously demonstrated that circulating NT-proBNP is truncated at the N and C termini. Aims of this study are three-fold: firstly to determine whether the NT-proBNP levels correlate with NYHA functional classes when measuring with different antibody pairs; secondly to evaluate the diagnostic potential of ProBNP and; thirdly to investigate whether combining NT-proBNP assays with or without ProBNP would lead to better diagnostic accuracies. Methods Plasma samples were collected from healthy controls (n = 52) and HF patients (n = 46). Customized AlphaLISA® immunoassays were developed and validated to measure the concentrations of proBNP and NT-proBNP (with antibodies targeting 13–45, 13–76, 28–76). The diagnostic performance and predictive value of proBNP and NT-proBNP assays and their combinations were evaluated. Results Plasma proBNP assay showed acceptable diagnostic performance. NT-proBNP13–76 assay is useful in diagnosing and stratifying HF patients. The diagnostic performance of NT-proBNP13–76 demonstrated improvement over commercial NT-proBNP tests. The combination of NT-proBNP13–76 with NT-proBNP28–76 assays gave the best diagnostic assay performance. Conclusion Our results demonstrate that while there is major heterogeneity in circulating NT-proBNP, specific epitopes of the peptides are extraordinarily stable, providing ideal targets for clinically useful diagnostic assays. Future new clinical diagnostic clinical trials should include a multimarker approach rather than using a single marker to diagnose HF

    Quantification of D-dimer levels in human saliva

    No full text
    Background: Plasma D-dimer tests are currently used to exclude deep vein thrombosis and pulmonary embolism. Human saliva has numerous advantages over blood as a diagnostic sample. The aims of our study were to develop a reliable immunoassay to detect D-dimer levels in saliva, and to determine the correlation between salivary and blood D-dimer levels. Results/methodology: Saliva and blood samples were collected from 40 healthy volunteers. We developed a AlphaLISA® immunoassay with acceptable analytical performances to quantify D-dimer levels in the samples. The median salivary D-dimer levels were 138.1 ng/ml (morning) and 140.7 ng/ml (afternoon), and the plasma levels were 75.0 ng/ml. Salivary D-dimer levels did not correlate with plasma levels (p = 0.61). Conclusion: For the first time, we have quantified D-dimer levels and found twofold increase in saliva (p < 0.05) than in plasma. Further studies are required to demonstrate the clinical relevance/utility of salivary D-dimer in patients with confirmed deep vein thrombosis and/or pulmonary embolism
    corecore