763 research outputs found
Association between Helicobacter pylori infection and interleukin 1β polymorphism predispose to CpG island methylation in gastric cancer [4]
published_or_final_versio
Evaluation of 3D printed PCL/PLGA/beta-TCP versus collagen membranes for guided bone regeneration in a beagle implant model
Here, we compared 3D-printed polycaprolactone/poly(lactic-co-glycolic acid)/beta-tricalcium phosphate (PCL/PLGA/beta-TCP) membranes with the widely used collagen membranes for guided bone regeneration (GBR) in beagle implant models. For mechanical property comparison in dry and wet conditions and cytocompatibility determination, we analyzed the rate and pattern of cell proliferation of seeded fibroblasts and preosteoblasts using the cell counting kit-8 assay and scanning electron microscopy. Osteogenic differentiation was verified using alizarin red S staining. At 8 weeks following implantation in vivo using beagle dogs, computed tomography and histological analyses were performed after sacrifice. Cell proliferation rates in vitro indicated that early cell attachment was higher in collagen than in PCL/PLGA/beta-TCP membranes; however, the difference subsided by day 7. Similar outcomes were found for osteogenic differentiation, with approximately 2.5 times greater staining in collagen than PCL/PLGA/beta-TCP, but without significant difference by day 14. In vivo, bone regeneration in the defect area, represented by new bone formation and bone-to-implant contact, paralleled those associated with collagen membranes. However, tensile testing revealed that whereas the PCL/PLGA/beta-TCP membrane mechanical properties were conserved in both wet and dry states, the tensile property of collagen was reduced by 99% under wet conditions. Our results demonstrate in vitro and in vivo that PCL/PLGA/beta-TCP membranes have similar levels of biocompatibility and bone regeneration as collagen membranes. In particular, considering that GBR is always applied to a wet environment (e.g. blood, saliva), we demonstrated that PCL/PLGA/beta-TCP membranes maintained their form more reliably than collagen membranes in a wet setting, confirming their appropriateness as a GBR membrane.11109Ysciescopu
Association between the mood stabilizing treatment of bipolar disorder and risk of suicide attempts: A self-controlled case series study
Bipolar disorder (BPD) is associated with high rates of suicide attempts but the anti-suicidal effect of mood stabilizing agents remains unclear. This study aimed to examine the association between mood stabilizing agents (lithium, valproate, lamotrigine, carbamazepine or antipsychotics) and risk of suicide attempts in patients with BPD using self-controlled case series study design.
Among 14,087 patients with BPD who received mood stabilizing agents from 2001 to 2020 in Hong Kong, 1316 patients had at least one suicide attempts during the observation period. An increased risk of suicide attempts was observed 14 days before treatment initiation compared to non-exposed period. Following treatment initiation, an increased risk with smaller magnitude was found with the use of mood stabilizing agents. A lower risk was observed with lithium and antiepileptics while the risk remained attenuated with decreasing magnitude with antipsychotics. During 30-day post-treatment period, the risk was elevated. Therefore, this study suggests that use of mood stabilizing agents is not causally associated with an increased risk of suicide attempts. Indeed, there are potential protective effects of lithium and antiepileptics against suicide attempts. Assiduous monitoring of symptoms relapse and warning signs of suicide should be part of the management plan and discussed between clinicians, caregivers and patients
Band-gap expansion in the surface-localized electronic structure of MoS2(0002)
The electronic band structure of MoS2 single crystals has been investigated using angle-resolved photoelectron spectroscopy and first-principles calculations. The orbital symmetry and k dispersion of these electronic states responsible for the direct and the indirect electronic band gaps have been unambiguously determined. By experimentally probing an increase of the electronic band gap, we conclude that a MoS2 (0002) surface localized state exists just below the valence band maximum at the Gamma point. This electronic state originates from the sulfur planes within the topmost layer. Our comprehensive study addresses the surface electronic structure of MoS2 and the role of van der Waals interlayer interactions.open112625Nsciescopu
Combining classifiers for robust PICO element detection
<p>Abstract</p> <p>Background</p> <p>Formulating a clinical information need in terms of the four atomic parts which are Population/Problem, Intervention, Comparison and Outcome (known as PICO elements) facilitates searching for a precise answer within a large medical citation database. However, using PICO defined items in the information retrieval process requires a search engine to be able to detect and index PICO elements in the collection in order for the system to retrieve relevant documents.</p> <p>Methods</p> <p>In this study, we tested multiple supervised classification algorithms and their combinations for detecting PICO elements within medical abstracts. Using the structural descriptors that are embedded in some medical abstracts, we have automatically gathered large training/testing data sets for each PICO element.</p> <p>Results</p> <p>Combining multiple classifiers using a weighted linear combination of their prediction scores achieves promising results with an <it>f</it>-measure score of 86.3% for P, 67% for I and 56.6% for O.</p> <p>Conclusions</p> <p>Our experiments on the identification of PICO elements showed that the task is very challenging. Nevertheless, the performance achieved by our identification method is competitive with previously published results and shows that this task can be achieved with a high accuracy for the P element but lower ones for I and O elements.</p
DNA resection in eukaryotes: deciding how to fix the break
DNA double-strand breaks are repaired by different mechanisms, including homologous
recombination and nonhomologous end-joining. DNA-end resection, the first step in
recombination, is a key step that contributes to the choice of DSB repair. Resection, an
evolutionarily conserved process that generates single-stranded DNA, is linked to checkpoint
activation and is critical for survival. Failure to regulate and execute this process results in
defective recombination and can contribute to human disease. Here, I review recent findings on
the mechanisms of resection in eukaryotes, from yeast to vertebrates, provide insights into the
regulatory strategies that control it, and highlight the consequences of both its impairment and its
deregulation
Temperature induced crossing in the optical bandgap of mono and bilayer MoS2 on SiO2
Photoluminescence measurements in mono- and bilayer-MoS2 on SiO2 were undertaken to determine the thermal effect of the MoS2/SiO2 interface on the optical bandgap. The energy and intensity of the photoluminescence from monolayer MoS2 were lower and weaker than those from bilayer MoS2 at low temperatures, whilst the opposite was true at high temperatures above 200 K. Density functional theory calculations suggest that the observed optical bandgap crossover is caused by a weaker substrate coupling to the bilayer than to the monolayer
Utilising accessible and reproducible neurological assessments in clinical studies: Insights from use of the Neurological Impairment Scale in the multi-centre COVID-CNS study
Reproducible and standardised neurological assessment scales are important in quantifying research outcomes. These scales are often performed by non-neurologists and/or non-clinicians and must be robust, quantifiable, reproducible and comparable to a neurologist's assessment. COVID-CNS is a multi-centre study which utilised the Neurological Impairment Scale (NIS) as a core assessment tool in studying neurological outcomes following COVID-19 infection. We investigated the strengths and weaknesses of the NIS when used by non-neurology clinicians and non-clinicians, and compared performance to a structured neurological examination performed by a neurology clinician. Through our findings, we provide practical advice on how non-clinicians can be readily trained in conducting reproducible and standardised neurological assessments in a multi-centre study, as well as illustrating potential pitfalls of these tools
- …