460 research outputs found

    3D turbine tip clearance flow redistribution due to gap variation

    Get PDF
    Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 1991.Includes bibliographical references (leaf 44).by Kai Yuen Eric Leung.M.S

    Barbosa et al. Reply to ``Comment on 'Secure Communication using mesoscopic coherent states', Barbosa et al, Phys Rev Lett 90, 227901", Yuan and Shields, Phys. Rev. Lett. 94, 048901(2005)

    Full text link
    Yuan and Shields claim that our data-encryption protocol is entirely equivalent to a classical stream cipher utilizing no quantum phenomena. Their claim is, indeed, false. Yuan and Shields also claim that schemes similar to the one presented in Phys. Rev. Lett. 90, 227901 are not suitable for key generation. This claim is also refuted. In any event, we welcome the opportunity to clarify the situation for a wider audience.Comment: This is the co-published Reply to the Comment made by Z.L. Yuan and A.J. Shields published in Physical Review Letters, 94 (2005

    Extreme cavity expansion in soft solids: damage without fracture

    Full text link
    Cavitation is a common damage mechanism in soft solids. Here, we study this using a phase-separation technique in stretched, elastic solids to controllably nucleate and grow small cavities by several orders of magnitude. The ability to make stable cavities of different sizes, as well as the huge range of accessible strains, allows us to systematically study the early stages of cavity expansion. Cavities grow in a scale-free manner, accompanied by irreversible bond breakage that is distributed around the growing cavity, rather than being localized to a crack tip. Furthermore, cavities appear to grow at constant driving pressure. This has strong analogies with the plasticity that occurs surrounding a growing void in ductile metals. In particular we find that, although elastomers are normally considered as brittle materials, small-scale cavity expansion is more like a ductile process. Our results have broad implications for understanding and controlling failure in soft solids

    Quantum Noise Randomized Ciphers

    Full text link
    We review the notion of a classical random cipher and its advantages. We sharpen the usual description of random ciphers to a particular mathematical characterization suggested by the salient feature responsible for their increased security. We describe a concrete system known as AlphaEta and show that it is equivalent to a random cipher in which the required randomization is effected by coherent-state quantum noise. We describe the currently known security features of AlphaEta and similar systems, including lower bounds on the unicity distances against ciphertext-only and known-plaintext attacks. We show how AlphaEta used in conjunction with any standard stream cipher such as AES (Advanced Encryption Standard) provides an additional, qualitatively different layer of security from physical encryption against known-plaintext attacks on the key. We refute some claims in the literature that AlphaEta is equivalent to a non-random stream cipher.Comment: Accepted for publication in Phys. Rev. A; Discussion augmented and re-organized; Section 5 contains a detailed response to 'T. Nishioka, T. Hasegawa, H. Ishizuka, K. Imafuku, H. Imai: Phys. Lett. A 327 (2004) 28-32 /quant-ph/0310168' & 'T. Nishioka, T. Hasegawa, H. Ishizuka, K. Imafuku, H. Imai: Phys. Lett. A 346 (2005) 7

    Longitudinal imaging of microvascular remodelling in proliferative diabetic retinopathy using adaptive optics scanning light ophthalmoscopy

    Get PDF
    Purpose To characterise longitudinal changes in the retinal microvasculature of type 2 diabetes mellitus (T2DM) as exemplified in a patient with proliferative diabetic retinopathy (PDR) using an adaptive optics scanning light ophthalmoscope (AOSLO). Methods A 35-year-old T2DM patient with PDR treated with scatter pan-retinal photocoagulation at the inferior retina 1 day prior to initial AOSLO imaging along with a 24-year-old healthy control were imaged in this study. AOSLO vascular structural and perfusion maps were acquired at four visits over a 20-week period. Capillary diameter and microaneurysm area changes were measured on the AOSLO structural maps. Imaging repeatability was established using longitudinal imaging of microvasculature in the healthy control. Results Capillary occlusion and recanalisation, capillary dilatation, resolution of local retinal haemorrhage, capillary hairpin formation, capillary bend formation, microaneurysm formation, progression and regression were documented over time in a region 2° superior to the fovea in the PDR patient. An identical microvascular network with same capillary diameter was observed in the control subject over time. Conclusions High-resolution serial AOSLO imaging enables in vivo observation of vasculopathic changes seen in diabetes mellitus. The implications of this methodology are significant, providing the opportunity for studying the dynamics of the pathological process, as well as the possibility of identifying highly sensitive and non-invasive biomarkers of end organ damage and response to treatment

    Dynamic Microclimate Boundaries across a Sharp Tropical Rainforest–Clearing Edge

    Get PDF
    As landscapes become increasingly fragmented, research into impacts from disturbance and how edges affect vegetation and community structure has become more important. Descriptive studies on how microclimate changes across sharp transition zones have long existed in the literature and recently more attention has been focused on understanding the dynamic patterns of microclimate associated with forest edges. Increasing concern about forest fragmentation has led to new technologies for modeling forest microclimates. However, forest boundaries pose important challenges to not only microclimate modeling but also sampling regimes in order to capture the diurnal and seasonal dynamic aspects of microclimate along forest edges. We measured microclimatic variables across a sharp boundary from a clearing into primary lowland tropical rainforest at La Selva Biological Station in Costa Rica. Dynamic changes in diurnal microclimate were measured along three replicated transects, approximately 30 m in length with data collected every 1 m continuously at 30 min intervals for 24 h with a mobile sensor platform supported by a cable infrastructure. We found that a first-order polynomial fit using piece-wise regression provided the most consistent estimation of the forest edge, relative to the visual edge, although we found no best sensing parameter as all measurements varied. Edge location estimates based on daytime net shortwave radiation had less difference from the visual edge than other shortwave measurements, but estimates made throughout the day with downward-facing or net infrared radiation sensors were more consistent and closer to the visual edge than any other measurement. This research contributes to the relatively small number of studies that have directly measured diurnal temporal and spatial patterns of microclimate variation across forest edges and demonstrates the use of a flexible mobile platform that enables repeated, high-resolution measurements of gradients of microclimate

    Compilation of reinforced carbon-carbon transatlantic abort landing arc jet test results

    Get PDF
    This document consists of the entire test database generated to support the Reinforced Carbon-Carbon Transatlantic Abort Landing Study. RCC components used for orbiter nose cap and wing leading edge thermal protection were originally designed to have a multi-mission entry capability of 2800 F. Increased orbiter range capability required a predicted increase in excess of 3300 F. Three test series were conducted. Test series #1 used ENKA-based RCC specimens coated with silicon carbide, treated with tetraethyl orthosilicate, sealed with Type A surface enhancement, and tested at 3000-3400 F with surface pressure of 60-101 psf. Series #2 used ENKA- or AVTEX-based RCC, with and without silicon carbide, Type A or double Type AA surface enhancement, all impregnated with TEOS, and at temperatures from 1440-3350 F with pressures from 100-350 psf. Series #3 tested ENKA-based RCC, with and without silicon carbide coating. No specimens were treated with TEOS or sealed with Type A. Surface temperatures ranged from 2690-3440 F and pressures ranged from 313-400 psf. These combined test results provided the database for establishing RCC material single-mission-limit temperature and developing surface recession correlations used to predict mass loss for abort conditions
    • …
    corecore