2,388 research outputs found

    Manufacture and Characterization of High Q-Factor Inductors Based on CMOS-MEMS Techniques

    Get PDF
    A high Q-factor (quality-factor) spiral inductor fabricated by the CMOS (complementary metal oxide semiconductor) process and a post-process was investigated. The spiral inductor is manufactured on a silicon substrate. A post-process is used to remove the underlying silicon substrate in order to reduce the substrate loss and to enhance the Q-factor of the inductor. The post-process adopts RIE (reactive ion etching) to etch the sacrificial oxide layer, and then TMAH (tetramethylammonium hydroxide) is employed to remove the silicon substrate for obtaining the suspended spiral inductor. The advantage of this post-processing method is its compatibility with the CMOS process. The performance of the spiral inductor is measured by an Agilent 8510C network analyzer and a Cascade probe station. Experimental results show that the Q-factor and inductance of the spiral inductor are 15 at 15 GHz and 1.8 nH at 1 GHz, respectively

    Wear and Corrosion Properties of Pure Mo Coating Layer Manufactured by Atmospheric Plasma Spray Process

    Get PDF
    A pure molybdenum (Mo) coating layer was manufactured by using the atmospheric plasma spray (APS) process and its wear and corrosion characteristics were investigated in this study. A Mo coating layer was prepared to a thickness of approximately 480 μm, and it had sound physical properties with a porosity of 2.9% and hardness of 434 Hv. Room temperature dry wear characteristics were measured through a ball-on-disk test under load conditions of 5 N, 10 N and 15 N. Based on the coefficient of friction graph at 5 N and 10 N, the oxides formed during wear functioned as a wear lubricant, thereby confirming an increase in wear resistance. However, at 15 N, wear behavior changed, and wear occurred due to splat pulling out. A potentiodynamic polarization test was conducted under an artificial seawater atmosphere, and Ecorr and Icorr measured 0.717 V and 7.2E-5 A/cm2, respectively. Corrosion mainly occurred at the splat boundary and pores that were present in the initial state. Based on the findings above, the potential application of APS Mo coating material was also discussed

    Causes and effects of 2008 financial crisis

    Get PDF
    Beginning in the mid 2007’s the US financial market started to slide into the “worst financial crisis since the Great Depression of the early 1930’s” (Thakor, 2015: p.156). The domino effect of several events and occasions were leading first to a countrywide recession in the USA then later spreading globally. In the following this term paper will deal with the main causes and effects of 2008 financial crisis. Unlike other topics in literature there is no consensus about the question of guilt in this sense. Among economists there are different approaches to explain the main causes of the financial crisis

    Interaction and ordering of vacancy defects in NiO

    Get PDF
    By using a first-principles method employing the local density approximation plus Hubbard parameter approach, we study point defects in NiO and interactions between them. The defect states associated with nickel or oxygen vacancies are identified within the energy gap. It is found that nickel vacancies introduce shallow levels in the density of states for the spin direction opposite to that of the removed Ni atom, while the oxygen vacancy creates more localized in-gap states. The interaction profiles between vacancies indicate that specific defect arrangements are strongly favored for both nickel and oxygen vacancies. In the case of nickel vacancies, defect ordering in a simple-cubic style is found to be most stable, leading to a half-metallic behavior. The ionized oxygen vacancies also show a tendency toward clustering, more strongly than neutral pairs. The microscopic origin of vacancy clustering is understood based on overlap integrals between defect states. © 2008 The American Physical Society.open343

    다양한 교정용 브라켓 원재료에 부착하는 mutans streptococci 양의 비교분석

    Get PDF
    Objective: To estimate the effects of bracket material type on enamel decalcification during orthodontic treatment, this study analyzed the adhesion level of mutans streptococci (MS) to orthodontic bracket materials in vivo. Methods: Three different types of orthodontic bracket materials were used: stainless steel, monocrystalline sapphire, and polycrystalline alumina. A balanced complete block design was used to exclude the effect of positional variation of bracket materials in the oral cavity. Three types of plastic individual trays were made and one subject placed the tray in the mouth for 12 hours. Then, the attached bacteria were isolated and incubated on a mitis salivadus media containing bacitracin for 48 hours. Finally, the number of colony forming units of MS was counted. The experiments were independently performed 5 times with each of the 3 trays, resulting in a total of 15 times. Mixed model ANOVA was used to compare the adhesion amount of MS. Results: There was no difference in colony forming units among the bracket materials irrespective of jaw and tooth position. Conclusions: This study suggested that the result of quantitative analysis of MS adhesion to various orthodontic bracket materials in vivo may differ from that of the condition in vitro. (Korean J Orthod 2009;39(2):105-111)

    Pulmonary hypertension due to obstructive sleep apnea in a child with Rubinstein-Taybi syndrome

    Get PDF
    Rubinstein-Taybi syndrome (RTS) is characterized by peculiar facies, mental retardation, broad thumbs, and great toes. Approximately one-third of the affected individuals have a variety of congenital heart diseases. They can also have upper airway obstruction during sleep, due to hypotonia and the anatomy of the oropharynx and airway, which make these patients susceptible to obstructive sleep apnea (OSA). In our case, pulmonary hypertension was caused, successively, by congenital heart defects (a large patent ductus arteriosus and arch hypoplasia) and obstructive sleep apnea during early infancy. The congenital heart defects were surgically corrected, but persistent pulmonary hypertension was identified 2 months after the operation. This pulmonary hypertension was due to OSA, and it was relieved by nasal continuous positive airway pressure. This case is the first report of pulmonary hypertension from OSA in a young infant with RTS