Improved estimators for the shape parameter in gamma regression
A regression model is considered in which the response variables
have gamma distributions with a common shape parameter. A review is
given of existing estimators for the shape parameter. Bias expressions
for the maximum likelihood estimates of the regression coe f f i c i ent s
and the shape parameter are developed. A new estima t o r f o r t h e shape
parameter based on bias correction for the maximum likelihood estimator
is shown to have markedly better variance and mean square error properties
in small to moderate sized samples. Approximations to the low
order moments of the Pearson statistic are derived for gamma regression
models with general link functions. These are used for the case of a
logarithmic link to develop new estimators for the shape parameter which
have better moment properties than the estimators based on the Pearson
statistic which have been used previously. Finally, the small sample
variance and mean square error efficiencies of the estimators relative
to the maximum likelihood estimator are evaluated by simulation for the
case of a single explanatory variable and a logarithmic link, for a
range of sample sizes less than or equal to 100
Recommended from our members
The frequency response of acoustic Doppler current profilers: Spatiotemporal response and implications for tidal turbine site assessment
The lifespan of a tidal turbine is strongly affected by the unsteady loading it experiences, so knowledge of the mean flow speed is not sufficient: unsteadiness must also be quantified. One of the most common turbulence measurement devices in the marine environment is the Acoustic Doppler Current Profiler (ADCP). The variance of steady velocity measurements from ADCPs has been studied in detail, but very little attention has been given to the fundamental limits of ADCPs in terms of the frequencies and lengthscales that they can capture.
In this paper, it is shown that the ADCP acts as a lowpass filter to eddies and that even optimistic calculations predict significant attenuation at lengthscales up to ten times the blade chord of a typical tidal turbine. For a typical 40 m deep channel wavelengths below 3-4 m are attenuated by 90% or more. Those eddies that are not filtered out are then subject to a distortion that will either amplify or attenuate the signal depending on the precise turbulence characteristics of the site in question. While this low-pass filtering may alter some global statistics by truncating the observed spectrum,
it is most damaging when data is extracted for particular frequencies, as a turbine designer may do when assessing unsteady loading and fatigue life.
It is therefore recommended that high-resolution turbulence data, e.g. from a hotwire, is captured over part of the water column and that this is used to calibrate ADCP data.© 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other work
Modelling ATR-FTIR Spectra of Dental Bonding Systems to Investigate Composition and Polymerisation Kinetics
Component ratios and kinetics are key to understanding and optimising novel formulations. This warrants investigation of valid methods. Attenuated Total Reflectance Fourier Transform Infra-Red (ATR)-FTIR spectra of separate primers/adhesives were modelled using summed spectra of solvents (water, ethanol), methacrylate monomers (HEMA (hydroxyethyl methacrylate), Bis-GMA (bisphenol A glycidyl methacrylate), and 10-MDP (10-methacryloyloxydecyl dihydrogen phosphate)), and fillers, multiplied by varying fractions. Filler loads were obtained following their separation from the adhesives, by analysing three repetitions (n = 3). Spectral changes during light exposure at 37 °C (20 s, LED 1100–1330 mW/cm2) were used to determine polymerisation kinetics (n = 3). Independent samples T-test was used for statistical analysis (significance level of 5%). FTIR modelling suggested a primer solvent percentage of OBFL (Optibond FL) (30%) was half that of CFSE (Clearfil SE 2) (60%). OBFL included ethanol and water, while CFSE included only water. Monomer peaks were largely those of HEMA with lower levels of phosphate monomers. OBFL/CFSE adhesive model spectra suggested that both contained equal volumes of Bis-GMA/HEMA, with CFSE having 10-MDP. Filler levels and spectra from OBFL (48 wt.%) and CFSE (5 wt.%) were different. Both systems reached a 50% conversion rate within seconds of light exposure. The final conversion for OBFL (74 ± 1%) was lower compared to CFSE (79 ± 2%) (p < 0.05). ATR-FTIR is a useful method to investigate relative levels of main components in bonding systems and their polymerisation kinetics. Such information is valuable to understanding such behaviour
Methacrylate peak determination and selection recommendations using ATR-FTIR to investigate polymerisation of dental methacrylate mixtures.
Investigation of polymerisation kinetics using ATR-FTIR systems is common in many dental studies. However, peak selection methods to calculate monomer-polymer conversion can vary, consequently affecting final results. Thus, the aim of this study is to experimentally confirm which method is less prone to systematic errors. Three commercial restorative materials were tested-Vertise Flow (VF), Constic and Activa Bioactive Restorative Kids. Firstly, Attenuated Total Reflectance Fourier Transform Infra-Red (ATR-FTIR) (Spectrum One, Perkin-Elmer, UK) spectra of monomers were acquired-10-methacryloyloxy decyl dihydrogen phosphate (10-MDP), bisphenol-A glycidyl dimethacrylate (Bis-GMA), 2-hydroxyethyl methacrylate (HEMA), triethyelene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA) to investigate proportionality of methacrylate peak heights versus concentration. Spectral changes upon light exposure of 2 mm discs of the restorative materials (irradiated for 20 s, LED curing unit 1100-1330 mW/cm2) were assessed to study polymerisation kinetics (n = 3), with continuous acquisition of spectra, before, during and after light exposure. Peak differences and degrees of conversion (DC %) were calculated using 1320/1336, 1320/1350 and 1636/1648 cm-1 as reaction/reference peaks. Inferential statistics included a MANOVA and within-subjects repeated measures ANOVA design (5% significance level). Proportionality of methacrylate peak height to concentration was confirmed, with the 1320/1352 cm-1 peak combination showing the lowest coefficient of variation (8%). Difference spectra of the polymerisation reaction showed noise interference around the 1500-1800 cm-1 region. Across the different materials, DC % results are highly dependent upon peak selection (p<0.001), with higher variability associated to the 1636 cm-1. Significant differences in the materials were only detected when the 1320 cm-1 peak was used (p<0.05). Within the same materials, methods were significantly different for Constic and Activa (p<0.05). It is possible to conclude that the 1320 cm-1 peak is more adequate to assess polymerisation of methacrylates and is therefore recommended
Judges and judging in the Court of Final Appeal: a statistical picture
The authors provide a unique perspective on how the Court of Final Appeal has operated from 1997 to 2010. The study tracks the rising caseload in the Court, considers the statistical profile of the new system of judges and notes the greater attention being paid by the final court to public law cases.published_or_final_versio
Modifying dental composites to formulate novel methacrylate-based bone cements with improved polymerisation kinetics, and mechanical properties
Objectives: The aim was to develop bone composites with similar working times, faster polymerisation and higher final conversion in comparison to Cortoss™. Additionally, low shrinkage/heat generation and improved short and longer-term mechanical properties are desirable. Methods: Four urethane dimethacrylate based composites were prepared using tri-ethylene-glycol dimethacrylate (TEGDMA) or polypropylene dimethacrylate (PPGDMA) diluent and 0 or 20 wt% fibres in the glass filler particles. FTIR was used to determine reaction kinetics, final degrees of conversions, and polymerisation shrinkage/heat generation at 37 °C. Biaxial flexural strength, Young's modulus and compressive strength were evaluated after 1 or 30 days in water. Results: Experimental materials all had similar inhibition times to Cortoss™ (140 s) but subsequent maximum polymerisation rate was more than doubled. Average experimental composite final conversion (76%) was higher than that of Cortoss™ (58%) but with less heat generation and shrinkage. Replacement of TEGDMA by PPGDMA gave higher polymerisation rates and conversions while reducing shrinkage. Early and aged flexural strengths of Cortoss™ were 93 and 45 MPa respectively. Corresponding compressive strengths were 164 and 99 MPa. Early and lagged experimental composite flexural strengths were 164–186 and 240–274 MPa whilst compressive strengths were 240–274 MPa and 226–261 MPa. Young's modulus for Cortoss™ was 3.3 and 2.2 GPa at 1 day and 1 month. Experimental material values were 3.4–4.8 and 3.0–4.1 GPa, respectively. PPGDMA and fibres marginally reduced strength but caused greater reduction in modulus. Fibres also made the composites quasi-ductile instead of brittle. Significance: The improved setting and higher strengths of the experimental materials compared to Cortoss™, could reduce monomer leakage from the injection site and material fracture, respectively. Lowering modulus may reduce stress shielding whilst quasi-ductile properties may improve fracture tolerance. The modified dental composites could therefore be a promising approach for future bone cements
Recommended from our members
A comparison of methods for determining ploidy in white sturgeon (Acipenser transmontanus)
Release of sturgeon with abnormal ploidy into the wild may result in reduced fitness due to lowered fertility in the F2 and subsequent generations. Further, there is evidence that ploidy affects reproductive development and caviar yield. Therefore, the ability to accurately characterize the ploidy of white sturgeon (Acipenser transmontanus)is essential for both commercial and conservation aquaculture. This study compares nuclear volume and whole erythrocyte long-axis lengths obtained using Coulter counter and blood smears, respectively, from captive white sturgeon from populations originating in California and Idaho. We examine which method provides the most accurate, time efficient and cost-effective characterization of ploidy in this species. Results from Coulter counter and blood smears were compared to results from flow cytometry, the gold standard for genome size analysis. Previous work suggests that blood smears can distinguish between 8N (diploid)and 12N (triploid)sturgeon, but further analysis is required to see if this method can also be used to identify 10N fish and to provide robust evidence of its utility in 8N and 12N fish across populations. In this study, we demonstrated that the Coulter counter had 100% agreement with flow cytometry in ploidy assignment, while blood smears vary in their accuracy based on population. Blood smears showed a high degree of overlap in erythrocyte long-axis length between 8N and 10N individuals as well as some overlap between 10N and 12N individuals in the California fish, and a high degree of overlap between 8N and 12N individuals in the Idaho fish. Although blood smears are time-intensive and vary in their ploidy assignment accuracy, they are a low-cost technique and as such may have some utility for caviar farms attempting to identify 12N individuals in a small number of broodstock. By comparing the accuracy, efficiency and cost of these three methods, sturgeon farmers and conservation hatcheries will be able to choose the best method for their needs in determining the ploidy of their fish. We determined that Coulter counter is equally accurate to flow cytometry and is also the most time efficient method for ploidy determination in white sturgeon
- …