1,857 research outputs found

    Biased alternative polyadenylation in human tissues

    Get PDF
    BACKGROUND: Alternative polyadenylation is one of the mechanisms in human cells that give rise to a variety of transcripts from a single gene. More than half of the human genes have multiple polyadenylation sites (poly(A) sites), leading to variable mRNA and protein products. Previous studies of individual genes have indicated that alternative polyadenylation could occur in a tissue-specific manner. RESULTS: We set out to systematically investigate the occurrence and mechanism of alternative polyadenylation in different human tissues using bioinformatic approaches. Using expressed sequence tag (EST) data, we investigated 42 distinct tissue types. We found that several tissues tend to use poly(A) sites that are biased toward certain locations of a gene, such as sites located in introns or internal exons, and various sites in the exon located closest to the 3' end. We also identified several tissues, including eye, retina and placenta, that tend to use poly(A) sites not frequently used in other tissues. By exploring microarray expression data, we analyzed over 20 genes whose protein products are involved in the process or regulation of mRNA polyadenylation. Several brain tissues showed high concordance of gene expression of these genes with each other, but low concordance with other tissue types. By comparing genomic regions surrounding poly(A) sites preferentially used in brain tissues with those in other tissues, we identified several cis-regulatory elements that were significantly associated with brain-specific poly(A) sites. CONCLUSION: Our results indicate that there are systematic differences in poly(A) site usage among human tissues, and both trans-acting factors and cis-regulatory elements may be involved in regulating alternative polyadenylation in different tissues

    A novel method for crystalline silicon solar cells with low contact resistance and antireflection coating by an oxidized Mg layer

    Get PDF
    One of the key issues in the solar industry is lowering dopant concentration of emitter for high-efficiency crystalline solar cells. However, it is well known that a low surface concentration of dopants results in poor contact formation between the front Ag electrode and the n-layer of Si. In this paper, an evaporated Mg layer is used to reduce series resistance of c-Si solar cells. A layer of Mg metal is deposited on a lightly doped n-type Si emitter by evaporation. Ag electrode is screen printed to collect the generated electrons. Small work function difference between Mg and n-type silicon reduces the contact resistance. During a co-firing process, Mg is oxidized, and the oxidized layer serves as an antireflection layer. The measurement of an Ag/Mg/n-Si solar cell shows that Voc, Jsc, FF, and efficiency are 602 mV, 36.9 mA/cm2, 80.1%, and 17.75%, respectively. It can be applied to the manufacturing of low-cost, simple, and high-efficiency solar cells

    Student Piano Trio: Ae-Sil Kim, Violin; Young Ju Lee, Cello; Koo Soon Youn, Piano; February 15, 1974

    Get PDF
    Centennial East Recital HallFriday EveningFebruary 15, 19748:15 p.m

    Selective emitter using a screen printed etch barrier in crystalline silicon solar cell

    Get PDF
    The low level doping of a selective emitter by etch back is an easy and low cost process to obtain a better blue response from a solar cell. This work suggests that the contact resistance of the selective emitter can be controlled by wet etching with the commercial acid barrier paste that is commonly applied in screen printing. Wet etching conditions such as acid barrier curing time, etchant concentration, and etching time have been optimized for the process, which is controllable as well as fast. The acid barrier formed by screen printing was etched with HF and HNO(3) (1:200) solution for 15 s, resulting in high sheet contact resistance of 90 Ω/sq. Doping concentrations of the electrode contact portion were 2 × 10(21) cm(−3) in the low sheet resistance (Rs) region and 7 × 10(19) cm(−3) in the high Rs region. Solar cells of 12.5 × 12.5 cm(2) in dimensions with a wet etch back selective emitter J(sc) of 37 mAcm(−2), open circuit voltage (V(oc)) of 638.3 mV and efficiency of 18.13% were fabricated. The result showed an improvement of about 13 mV on V(oc) compared to those of the reference solar cell fabricated with the reactive-ion etching back selective emitter and with J(sc) of 36.90 mAcm(−2), V(oc) of 625.7 mV, and efficiency of 17.60%

    The validity of the canadian triage and acuity scale in predicting resource utilization and the need for immediate life-saving interventions in elderly emergency department patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We evaluated the validity of the Canadian Triage and Acuity Scale (CTAS) in elderly emergency department (ED) patients. In particular, we examined the sensitivity and specificity of the CTAS for identifying elderly patients who received an immediate life-saving intervention in the ED.</p> <p>Methods</p> <p>We reviewed the medical records of consecutive patients who were 65 years of age or older and presented to a single academic ED within a three-month period. The CTAS triage scores were compared to actual patient course, including disposition, discharge outcome and resource utilization. We calculated the sensitivity and specificity of the CTAS triage for identifying patients who received an immediate intervention.</p> <p>Results</p> <p>Of the 1903 consecutive patients who were ≥ 65 years of age, 113 (5.9%) had a CTAS level of 1, 174 (9.1%) had a CTAS level of 2, 1154 (60.6%) had a CTAS level of 3, 347 (18.2%) had a CTAS level of 4, and 115 (6.0%) had a CTAS level of 5. As a patient's triage score increased, the severity (such as mortality and intensive care unit admission) and resource utilization increased significantly. Ninety-four of the patients received a life-saving intervention within an hour following their arrival to the ED. The CTAS scores for these patients were 1, 2 and 3 for 46, 46 and 2 patients, respectively. The sensitivity and specificity of a CTAS score of ≤ 2 for identifying patients for receiving an immediate intervention were 97.9% and 89.2%, respectively.</p> <p>Conclusions</p> <p>The CTAS is a triage tool with high validity for elderly patients, and it is an especially useful tool for categorizing severity and for recognizing elderly patients who require immediate life-saving intervention.</p

    Normal stress difference-driven particle focusing in nanoparticle colloidal dispersion

    Get PDF
    Colloidal dispersion has elastic properties due to Brownian relaxation process. However, experimental evidence for the elastic properties, characterized with normal stress differences, is elusive in shearing colloidal dispersion, particularly at low Peclet numbers (Pe &lt; 1). Here, we report that single micrometer-sized polystyrene (PS) beads, suspended in silica nanoparticle dispersion (8 nm radius; 22%, v/v), laterally migrate and form a tightly focused stream by the normal stress differences, generated in pressure-driven microtube flow at low Pe. The nanoparticle dispersion was expected to behave as a Newtonian fluid because of its ultrashort relaxation time (2 mu s), but large shear strain experienced by the PS beads causes the notable non-Newtonian behavior. We demonstrate that the unique rheological properties of the nanoparticle dispersion generate the secondary flow in perpendicular to mainstream in a noncircular conduit, and the elastic properties of blood plasma-constituting protein solutions are elucidated by the colloidal dynamics of protein molecules
    corecore