28 research outputs found
Recommended from our members
Circular collimator arc versus dynamic conformal arc treatment planning for linac-based stereotactic radiosurgery of an intracranial small single lesion: a perspective of lesion asymmetry
Background: Although circular collimator arcs (CCA) and dynamic conformal arcs (DCA) are commonly used linear accelerator-based treatment planning techniques for intracranial stereotactic radiosurgery (SRS) of a small single lesion, these two techniques have not been rigorously compared in terms of tumor shape. Therefore, this study compared clinical CCA plans with re-planned DCA plans using conformity index (CI) and V12Gy (volume of normal brain tissue receiving 12 Gy or higher) from a perspective of asymmetry (Asym) of planning target volume (PTV). Methods: Ninety-five clinical CCA plans delivered for a small single lesion with PTV size < 1.4 cm3 were selected and re-planned using DCA. PTV Asym (%) was defined and calculated from three dimensions of PTV. A pair of the 95 plans was first considered as one group without grouping and then categorized into two groups with respective to either PTV size or PTV Asym, and four groups with respect to PTV size and PTV Asym. For grouping,
median values of PTV size and PTV Asym were used. A non-parametric paired test was performed for CI and V12Gy to compare CCA and DCA plans in each group. Results: Median values of PTV size and PTV Asym were 0.415 cm3 (range: 0.076 cm3–1.369 cm3) and 6.12% (range: 0.52–25.74%), respectively. DCA plans had a lower average CI value than CCA plans for all groups. CCA plans had a smaller average V12Gy value than DCA plans for lesions with PTV Asym ≤6.12%, while CCA and DCA plans had similar average V12Gy values for lesions with PTV Asym > 6.12%. Conclusions: The DCA technique is recommended when a lesion has PTV Asym > 6.12% regardless of PTV size. For lesions with PTV Asym ≤6.12%, a technique choice would depend on the preference of CI or V12Gy.Open access journalThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]
Fast signing method in RSA with high speed verification
In this paper, we propose the method to speed up signature generation in RSA with small public exponent. We first divide the signing algorithm into two stages. One is message generating stage and the other is signing stage. Next, we modify the RSA signature so that the bulk of the calculation cost is allocated to message generating stage. This gives the possibility to propose the RSA signature schemes which have fast signature generation and very fast verification. Our schemes are suited for the applications in which a message is generated offline, but needs to be quickly signed and verified online
A route to high surface area, porosity and inclusion of large molecules in crystals
One of the outstanding challenges in the field of porous materials is the design and synthesis of chemical structures with exceptionally high surface areas(1). Such materials are of critical importance to many applications involving catalysis, separation and gas storage. The claim for the highest surface area of a disordered structure is for carbon, at 2,030 m(2) g(-1) (ref. 2). Until recently, the largest surface area of an ordered structure was that of zeolite Y, recorded at 904 m(2) g(-1) (ref. 3). But with the introduction of metal-organic framework materials, this has been exceeded, with values up to 3,000 m(2) g(-1) (refs 4-7). Despite this, no method of determining the upper limit in surface area for a material has yet been found. Here we present a general strategy that has allowed us to realize a structure having by far the highest surface area reported to date. We report the design, synthesis and properties of crystalline Zn4O(1,3,5-benzenetribenzoate)(2), a new metal-organic framework with a surface area estimated at 4,500 m(2) g(-1). This framework, which we name MOF-177, combines this exceptional level of surface area with an ordered structure that has extra-large pores capable of binding polycyclic organic guest molecules-attributes not previously combined in one material.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/62609/1/nature02311.pd
A practical approach to estimating optic disc dose and macula dose without treatment planning in ocular brachytherapy using I COMS plaques
It has been reported that proximity of the tumor to the optic disc and macula, and radiation dose to the critical structures are substantial risk factors for vision loss following plaque brachytherapy. However, there is little dosimetry data published on this. In this study, therefore, the relationship between distance from tumor margin and radiation dose to the optic disc and macula in ocular brachytherapy using 125I Collaborative Ocular Melanoma Study (COMS) plaques was comprehensively investigated. From the information, this study aimed to allow for estimation of optic disc dose and macula dose without treatment planning.Open access journalThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]
Optic disc dose reduction in ocular brachytherapy using(125)I notched COMS plaques: A simulation study based on current clinical practice
Purpose Although notched Collaborative Ocular Melanoma Study (COMS) plaques have been widely used, optic disc dose reduction by notched COMS plaques has not been discussed in the literature. Therefore, this study investigated optic disc dose reduction in ocular brachytherapy using(125)I notched COMS plaques in comparison with optic disc dose for(125)I standard COMS plaques. Methods For this simulation study, an in-house brachytherapy dose calculation program was developed using MATLAB software by incorporating the American Association of Physicists in Medicine Task Group-43 Update (AAPM TG-43U1) dosimetry formalism with a line source approximation in a homogeneous water medium and COMS seed coordinates in the AAPM TG 129. Using this program, optic disc doses for standard COMS plaques (from 12 to 22 mm in diameter in 2 mm increments) and notched COMS plaques with one seed removed (Case #1, from 12 to 22 mm) and with two seeds removed (Case #2, from 14 to 22 mm) were calculated as a function of tumor margin-to-optic disc distance (DT) for various tumor basal dimensions (BDs) for prescription depths from 1 to 10 mm in 1 mm intervals. A dose of 85 Gy for an irradiation time of 168 h was prescribed to each prescription depth. Then absolute and relative optic disc dose reduction by notched COMS plaques (Cases #1 and #2) was calculated for all prescription depths. Results Optic disc dose reduction by notched COMS plaques (Cases #1 and #2) had five unique trends related to maximum optic disc dose reduction and corresponding optimal DT for each BD in each plaque. It increased with increasing prescription depth. Conclusions The results presented in this study would enable the clinician to choose an adequate plaque type among standard and notched(125)I COMS plaques and a prescription depth to minimize optic disc dose.Open access journalThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]