412 research outputs found

    On the Use of Various Oscillatory Air Flow Fields for Characterization of Biomimetic Hair Flow Sensors

    Get PDF
    To determine the characteristics of flow sensors, a suitable source for flow generation is required. We discuss three different sources for oscillating air flow, by considering their acoustic impedance, frequency range, velocity and ability to distinguish between flow and pressure. We discuss the impact of these sources on characterization of our biomimetic hair flow sensors, which operate at flow velocities from 1–100 mm/s within a frequency range from 10–1000 Hz

    A Three Dimensional Microflown

    Get PDF
    An integrated three dimensional acoustic particle velocity sensor is realized. The integration of multiple sensors on a single silicon die leads to improvements in terms of better a better reproducible sensor and a very small sensor to sensor distance allowing accurate single point measurements. Initial measurements performed show that three dimensional noise source finding is possible with this sensor

    Preliminary Analysis of Concurrent Jurisdiction

    Get PDF

    Excitation and detection of vibrations of micromechanical structures using a dielectric thin film

    Get PDF
    A new technique is introduced for both the excitation and the detection of vibrations of micromechanical structures. This makes use of a dielectric thin film, sandwiched between lower and upper electrodes, on top of the vibrating structure. The excitation is based on electrostatic forces between the charged electrodes, causing deformation of the dielectric film and bending of the multilayer structure. The detection of the vibration is capacitive, based on the fluctuation of the capacitance due to the deformation of the dielectric film. Experimental results for a stoichiometric silicon nitride dielectric film on top of a silicon cantilever agree well with predicted values. The yield of the electrostatic excitation as well as of the capacitive detection are satisfactory

    Book Reviews

    Get PDF
    A collection of book reviews by multiple authors

    Book Reviews

    Get PDF
    Cases on Quasi Contract, by Edward S. Thurston. American Case Book Series. St. Paul: West Publishing Co., I916; pp. 622

    Sum rules for isospin centroids in pick-up reactions on general multishell target states

    Full text link
    Sum Rules equations for pick-up reactions are presented for the first time for the energy centroids of states both for the isospin T_< (\equiv T_0 - 1 \over 2) and T_> (\equiv T_0 + {1 \over 2}) of the final nucleus when a nucleon is picked up from a general multishell target state with isospin T_0. These equations contain two-body correlation terms, , which, at the present moment, are difficult to handle analytically. These terms are managed by combining these equations with the known stripping reactions equations. Sample applications of these equations to experimental data are presented.Comment: 11 pages, LaTe

    Stable long-term outcomes after cochlear implantation in subjects with TMPRSS3 associated hearing loss:a retrospective multicentre study

    Get PDF
    Background: The spiral ganglion hypothesis suggests that pathogenic variants in genes preferentially expressed in the spiral ganglion nerves (SGN), may lead to poor cochlear implant (CI) performance. It was long thought that TMPRSS3 was particularly expressed in the SGNs. However, this is not in line with recent reviews evaluating CI performance in subjects with TMPRSS3-associated sensorineural hearing loss (SNHL) reporting overall beneficial outcomes. These outcomes are, however, based on variable follow-up times of, in general, 1 year or less. Therefore, we aimed to 1. evaluate long-term outcomes after CI implantation of speech recognition in quiet in subjects with TMPRSS3-associated SNHL, and 2. test the spiral ganglion hypothesis using the TMPRSS3-group. Methods: This retrospective, multicentre study evaluated long-term CI performance in a Dutch population with TMPRSS3-associated SNHL. The phoneme scores at 70 dB with CI in the TMPRSS3-group were compared to a control group of fully genotyped cochlear implant users with post-lingual SNHL without genes affecting the SGN, or severe anatomical inner ear malformations. CI-recipients with a phoneme score ≤ 70% at least 1-year post-implantation were considered poor performers and were evaluated in more detail. Results: The TMPRSS3 group consisted of 29 subjects (N = 33 ears), and the control group of 62 subjects (N = 67 ears). For the TMPRSS3-group, we found an average phoneme score of 89% after 5 years, which remained stable up to 10 years post-implantation. At both 5 and 10-year follow-up, no difference was found in speech recognition in quiet between both groups (p = 0.830 and p = 0.987, respectively). Despite these overall adequate CI outcomes, six CI recipients had a phoneme score of ≤ 70% and were considered poor performers. The latter was observed in subjects with residual hearing post-implantation or older age at implantation. Conclusion: Subjects with TMPRSS3-associated SNHL have adequate and stable long-term outcomes after cochlear implantation, equal to the performance of genotyped patient with affected genes not expressed in the SGN. These findings are not in line with the spiral ganglion hypothesis. However, more recent studies showed that TMPRSS3 is mainly expressed in the hair cells with only limited SGN expression. Therefore, we cannot confirm nor refute the spiral ganglion hypothesis.</p

    Stable long-term outcomes after cochlear implantation in subjects with TMPRSS3 associated hearing loss:a retrospective multicentre study

    Get PDF
    Background: The spiral ganglion hypothesis suggests that pathogenic variants in genes preferentially expressed in the spiral ganglion nerves (SGN), may lead to poor cochlear implant (CI) performance. It was long thought that TMPRSS3 was particularly expressed in the SGNs. However, this is not in line with recent reviews evaluating CI performance in subjects with TMPRSS3-associated sensorineural hearing loss (SNHL) reporting overall beneficial outcomes. These outcomes are, however, based on variable follow-up times of, in general, 1 year or less. Therefore, we aimed to 1. evaluate long-term outcomes after CI implantation of speech recognition in quiet in subjects with TMPRSS3-associated SNHL, and 2. test the spiral ganglion hypothesis using the TMPRSS3-group. Methods: This retrospective, multicentre study evaluated long-term CI performance in a Dutch population with TMPRSS3-associated SNHL. The phoneme scores at 70 dB with CI in the TMPRSS3-group were compared to a control group of fully genotyped cochlear implant users with post-lingual SNHL without genes affecting the SGN, or severe anatomical inner ear malformations. CI-recipients with a phoneme score ≤ 70% at least 1-year post-implantation were considered poor performers and were evaluated in more detail. Results: The TMPRSS3 group consisted of 29 subjects (N = 33 ears), and the control group of 62 subjects (N = 67 ears). For the TMPRSS3-group, we found an average phoneme score of 89% after 5 years, which remained stable up to 10 years post-implantation. At both 5 and 10-year follow-up, no difference was found in speech recognition in quiet between both groups (p = 0.830 and p = 0.987, respectively). Despite these overall adequate CI outcomes, six CI recipients had a phoneme score of ≤ 70% and were considered poor performers. The latter was observed in subjects with residual hearing post-implantation or older age at implantation. Conclusion: Subjects with TMPRSS3-associated SNHL have adequate and stable long-term outcomes after cochlear implantation, equal to the performance of genotyped patient with affected genes not expressed in the SGN. These findings are not in line with the spiral ganglion hypothesis. However, more recent studies showed that TMPRSS3 is mainly expressed in the hair cells with only limited SGN expression. Therefore, we cannot confirm nor refute the spiral ganglion hypothesis.</p

    Molecular Characterization of the Gastrula in the Turtle Emys orbicularis: An Evolutionary Perspective on Gastrulation

    Get PDF
    Due to the presence of a blastopore as in amphibians, the turtle has been suggested to exemplify a transition form from an amphibian- to an avian-type gastrulation pattern. In order to test this hypothesis and gain insight into the emergence of the unique characteristics of amniotes during gastrulation, we have performed the first molecular characterization of the gastrula in a reptile, the turtle Emys orbicularis. The study of Brachyury, Lim1, Otx2 and Otx5 expression patterns points to a highly conserved dynamic of expression with amniote model organisms and makes it possible to identify the site of mesoderm internalization, which is a long-standing issue in reptiles. Analysis of Brachyury expression also highlights the presence of two distinct phases, less easily recognizable in model organisms and respectively characterized by an early ring-shaped and a later bilateral symmetrical territory. Systematic comparisons with tetrapod model organisms lead to new insights into the relationships of the blastopore/blastoporal plate system shared by all reptiles, with the blastopore of amphibians and the primitive streak of birds and mammals. The biphasic Brachyury expression pattern is also consistent with recent models of emergence of bilateral symmetry, which raises the question of its evolutionary significance
    corecore