409 research outputs found

    Gradient high performance liquid chromatography method for simultaneous determination of ilaprazole and its related impurities in commercial tablets

    Get PDF
    AbstractA methodology (HPLC) proposed in this paper for simultaneously quantitative determination of ilaprazole and its related impurities in commercial tablets was developed and validated. The chromatographic separation was carried out by gradient elution using an Agilent C8 column (4.6 mm × 250 mm, 5 μm) which was maintained at 25 °C. The mobile phase composed of solvent A (methanol) and solvent B (solution consisting 0.02 mmol/l monopotassium phosphate and 0.025 mmol/l sodium hydroxide) was at a flow rate of 1.0 ml/min. The samples were detected and quantified at 237 nm using an ultraviolet absorbance detector. Calibration curves of all analytes from 0.5 to 3.5 μg/ml were good linearity (r ≥ 0.9990) and recovery was greater than 99.5% for each analyte. The lower limit of detection (LLOD) and quantification (LOQ) of this analytical method were 10 ng/ml and 25 ng/ml for all impurities, respectively. The stress studies indicated that the degradation products could not interfere with the detection of ilaprazole and its related impurities and the assay can thus be considered stability-indicating. The method precisions were in the range of 0.41–1.21 while the instrument precisions were in the range of 0.38–0.95 in terms of peak area RSD% for all impurities, respectively. This method is considered stability-indicating and is applicable for accurate and simultaneous measuring of the ilaprazole and its related impurities in commercial enteric-coated tablets

    PERFORMANCE COMPARISON OF SYNGAS METHANATION ON FLUIDIZED AND FIXED BED REACTORS

    Get PDF
    The performance was compared on Syngas Completely Methanation at atmospheric pressure on fluidized and fixed bed reactors. From space-time yield of CH4, coke content and hot spots of bed temperature, fluidized bed technology was demonstrated to be more applicable to Syngas Completely Methanation. Characterization results showed that different carbon deposition forms were presented on the two operation modes

    Gas Sensitivity of In0.3Ga0.7As Surface QDs Coupled to Multilayer Buried QDs

    Get PDF
    AbstractA detailed analysis of the electrical response of In0.3Ga0.7As surface quantum dots (SQDs) coupled to 5-layer buried quantum dots (BQDs) is carried out as a function of ethanol and acetone concentration while temperature-dependent photoluminescence (PL) spectra are also analyzed. The coupling structure is grown by solid source molecular beam epitaxy. Carrier transport from BQDs to SQDs is confirmed by the temperature-dependent PL spectra. The importance of the surface states for the sensing application is once more highlighted. The results show that not only the exposure to the target gas but also the illumination affect the electrical response of the coupling sample strongly. In the ethanol atmosphere and under the illumination, the sheet resistance of the coupling structure decays by 50% while it remains nearly constant for the reference structure with only the 5-layer BQDs but not the SQDs. The strong dependence of the electrical response on the gas concentration makes SQDs very suitable for the development of integrated micrometer-sized gas sensor devices

    Overexpression of Class III β-tubulin, Sox2, and nuclear Survivin is predictive of taxane resistance in patients with stage III ovarian epithelial cancer

    Get PDF
    Failed root canal treatment is best addressed primarily with the provision of repeat endodontic treatment with thorough irrigation under isolation. If a post is present in the root of the tooth it needs to be removed first. This paper is the second in a series of two which provide an overview of techniques for post removal. Specifically designed post removal devices and the removal of fibre posts are described. Post removal device techniques are illustrated with a series of clinical case figures

    Micelle-like particles formed by carboxylic acid-terminated polystyrene and poly(4-vinyl pyridine) in chloroform/methanol mixed solution

    Get PDF
    Abstract Preparation and characterization of isolated particles and clusters of carboxylic acid-terminated polystyrene (CPS) and poly(4-vinyl pyridine) (P4VP) blends in chloroform/methanol (9/1, v/v) solution are reported. In chloroform CPS-P4VP blends form graft-like structure due to the interaction between terminal carboxylic acid and 4VP units. Upon addition of methanol, isolated particles and clusters with micelle-like structure were prepared. Dynamic light scattering (DLS) results and transmission electron microscopy (TEM) images both suggest the existence of isolated particles and clusters with micelle-like structure in the mixed solution. The effects of weight ratio of CPS to P4VP and addition of copper ion on the size of isolated particles and clusters were also investigated.
    • …
    corecore