459 research outputs found

    Line bisection performance in patients with generalized anxiety disorder and treatment-resistant depression

    Get PDF
    Background and Objectives The line bisection error to the left of the true center has been interpreted as a relative right hemisphere activation, which might relate to the subject's emotional state. Considering that patients with generalized anxiety disorder (GAD) or treatment-resistant depression (TRD) often have negative emotions, we hypothesized that these patients would bisect lines significantly leftward. Methods We tried the line bisection task in the right-handed healthy volunteers (n = 56), GAD (n = 47) and TRD outpatients (n = 52). Subjects also completed the Zuckerman - Kuhlman Personality Questionnaire, the Zuckerman Sensation Seeking Scales, and the Plutchik-van Praag Depression Inventory. Results GAD patients scored highest on the Neuroticism-Anxiety trait, TRD patients scored highest on depression, and both patients scored lower on the Sociability trait. Patients with GAD also bisected lines significantly leftward compared to the healthy subjects. The Frequency of the bisection error was negatively correlated with Disinhibition-Seeking in the healthy subjects, and with Total sensation-seeking and Experience-Seeking in GAD patients, while the Magnitude of the line bisection error was negatively correlated with depression in TRD patients. Conclusions The study suggests a stronger right hemispheric activation, a weaker left activation, or both in the GAD, instead of TRD patients

    Can digital service trade promote the high-quality development of global manufacturing? – existence and mechanism

    Get PDF
    Purpose – This thesis deeply studies the impact mechanism of digital service trade on the high-quality development of the manufacturing industry from the aspects of technological innovation and industrial structure. Design/methodology/approach – In this thesis, 40 countries from 2010 to 2020 were selected as samples, and the panel fixed-effect model and intermediary effect model were used to empirically analyze the impact path of digital service trade on the high-quality development of global manufacturing. Findings – Overall, digital service trade has a positive impact on the high-quality development of the global manufacturing industry. Through the analysis of the intermediary effect mechanism, it is found that digital service trade can further positively affect the high-quality development of the global manufacturing industry by promoting technological innovation and industrial structure upgrading. Research limitations/implications – Based on the empirical results, targeted countermeasures and suggestions are given in this paper. Practical implications – Through the test of national heterogeneity, it is found that in developing countries, digital service trade mainly acts on the high-quality development of the manufacturing industry by promoting industrial structure upgrading. Social implications – In developed countries, digital service trade mainly promotes the high-quality development of manufacturing through technological innovation; from the perspective of industry heterogeneity, the three service industries of information and communication technology (ICT), other business services and property have the intermediary effect of technological innovation and industrial structure. Originality/value – This manuscript suggests that trade in digital services should be promoted as a national trade priority

    Fake Alignment: Are LLMs Really Aligned Well?

    Full text link
    The growing awareness of safety concerns in large language models (LLMs) has sparked considerable interest in the evaluation of safety within current research endeavors. This study investigates an interesting issue pertaining to the evaluation of LLMs, namely the substantial discrepancy in performance between multiple-choice questions and open-ended questions. Inspired by research on jailbreak attack patterns, we argue this is caused by mismatched generalization. That is, the LLM does not have a comprehensive understanding of the complex concept of safety. Instead, it only remembers what to answer for open-ended safety questions, which makes it unable to solve other forms of safety tests. We refer to this phenomenon as fake alignment and construct a comparative benchmark to empirically verify its existence in LLMs. Such fake alignment renders previous evaluation protocols unreliable. To address this, we introduce the Fake alIgNment Evaluation (FINE) framework and two novel metrics--Consistency Score (CS) and Consistent Safety Score (CSS), which jointly assess two complementary forms of evaluation to quantify fake alignment and obtain corrected performance estimates. Applying FINE to 14 widely-used LLMs reveals several models with purported safety are poorly aligned in practice. Our work highlights potential limitations in prevailing alignment methodologies

    High-sensitivity intravascular photoacoustic imaging of lipid-laden plaque with a collinear catheter design

    Get PDF
    A highly sensitive catheter probe is critical to catheter-based intravascular photoacoustic imaging. Here, we present a photoacoustic catheter probe design on the basis of collinear alignment of the incident optical wave and the photoacoustically generated sound wave within a miniature catheter housing for the first time. Such collinear catheter design with an outer diameter of 1.6 mm provided highly efficient overlap between optical and acoustic waves over an imaging depth of >6 mm in D2O medium. Intravascular photoacoustic imaging of lipid-laden atherosclerotic plaque and perivascular fat was demonstrated, where a lab-built 500 Hz optical parametric oscillator outputting nanosecond optical pulses at a wavelength of 1.7 μm was used for overtone excitation of C-H bonds. In addition to intravascular imaging, the presented catheter design will benefit other photoacoustic applications such as needle-based intramuscular imaging

    AgBr-Coupled TiO 2

    Get PDF
    A series of AgBr/TiO2 visible photocatalysts with heterojunction structure was synthesized using Ti(OC4H9)4, KBr, and AgNO3 as precursors. The phase composition, particle morphology and size, microstructures, and absorbance of these photocatalysts were characterized by X-ray diffraction, transmission electron microscope (TEM), high-resolution TEM, and UV-vis spectra. It was found that the coupled AgBr/TiO2 was an effective photocatalyst to degrade the methylene blue under visible light irradiation, compared with the other noncoupled photocatalysts of AgBr, AgBr/P25, and P25. The photocatalytic activities of AgBr/TiO2 increase first and then decrease with increasing the mass ratio of mAgNO3/mTiO2 and the photocatalyst with the mass ratio of 3.35 has the highest photocatalytic activity. The results showed that the coupled photocatalyst has the particle size of about 15 nm with homogeneous dispersion and has the strongest absorption in whole UV-vis light region (250∼800 nm) originated from the synergetic effect of heterostructured AgBr/TiO2. The coupled AgBr/TiO2 photocatalyst can keep stable photocatalytic activity after five-circle runs

    Safety and efficacy of rapid withdrawal of anti-seizure medication during long-term video-EEG monitoring

    Get PDF
    ObjectiveAnti-seizure medications (ASMs) are often withdrawn during long-term video-EEG monitoring (LTM) to allow pre-surgical evaluation. Herein, we evaluated the safety and efficacy of ultra-rapid withdrawal (URW) and rapid withdrawal (RW) of ASMs in an epilepsy monitoring unit (EMU).MethodsThis retrospective study examined all consecutive patients admitted to our EMU between May 2021 and October 2022. Patients were classified into the URW and RW groups according to the way ASMs were withdrawn. We compared the efficacy and safety of the procedures used in the groups in terms of duration of LTM, latency to the first seizure, and incidence of focal to bilateral tonic–clonic seizures (FBTCS), seizure clusters (SC), and status epilepticus (SE).ResultsOverall, 110 patients (38 women) were included. The mean age of patients at the time of LTM was 29 years. All medications were stopped on admission for monitoring in the URW group (n = 75), while in the RW group (n = 35) ASMs were withdrawn within 1 day. In both groups, the duration of LTM was approximately 3 days: URW group (2.9 ± 0.5 days) and RW group (3.1 ± 0.8 days). The latency to the first seizure was significantly different between the two groups; however, there were no differences between the two groups in terms of the distribution of FBTCS, SC, or SE, number of seizures, and the requirement for intravenous rescue medication was low.ConclusionThe rapid withdrawal of ASMs to provoke seizures during monitoring for pre-surgical evaluation following the URW protocol was as effective and safe as with RW. Ultra-rapid ASM withdrawal has the benefits of reducing LTM duration and shortening the time to first seizure compared to rapid medication tapering

    Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second

    Get PDF
    Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critical for clinical utility of the IVPA-US imaging technology. Here, we demonstrate a portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter size, differentiated A-line strategy, and real-time image processing and display algorithms. Spatial resolution, chemical specificity, and capability for imaging highly dynamic objects were evaluated by phantoms to characterize system performance. An imaging speed of 16 frames per second was determined to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology. Thus, this high-speed IVPA-US imaging system presents significant advances in the translational intravascular and other endoscopic applications

    Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque at speed of video-rate level

    Get PDF
    Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipidladen plaques by providing simultaneous morphological and lipid-specific chemical information of an artery wall. The clinical utility of IVPA-US technology requires real-time imaging and display at speed of video-rate level. Here, we demonstrate a compact and portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter, differentiated A-line strategy, and real-time image processing and display algorithms. By imaging pulsatile motion at different imaging speeds, 16 frames per second was deemed to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. Our lateral resolution results further verified the number of A-lines used for a cross-sectional IVPA image reconstruction. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology
    corecore