95 research outputs found

    Design A High Performance Dual Ported 1 Read 1 Write CMOS SRAM

    Get PDF
    A synchronous dual-ported high speed and low power CMOS SRAM is described. This SRAM is an 8T (transistors) architecture that has 8 transistors in every single memory cell that are capable of performing a read and write operation in one cycle, under the condition that it is not performing the read and write operation in the same decoded address simultaneously. The proposed SRAM has 4Kbit memory capacity with 33 entries and 128 size of entry and was custom designed using 90nm process. The SRAM is operating properly with supply voltage of 1.05V. The targeted operating frequency is at 125MHz and it dissipates a maximum active power of 10.5mW and consumes a maximum standby power of 2.1mW. The targeted current consumption for the SRAM is having a maximum active value of 10mA and a maximum standby current of 2mA. The functionality of the SRAM is guaranteed by running simulations over a wide range of Process, Voltage and Temperature (PVT) corners. Internal race checking for SRAM has been adopted to perform further verification to ensure that there’s no failing signal in the SRAM that will cause functional error and excess power consumption in SRAM

    Special issue introduction: New research directions and critical perspectives on diaspora strategies  

    Get PDF
    10.1016/j.geoforum.2014.12.006Geoforum59153-15

    Recasting diaspora strategies through feminist care ethics

    Get PDF
    Geoforum59206-21

    Migration and Integration. Common Challenges and Responses from Europe and Asia

    Get PDF
    With the signing of the ASEAN Framework Agreement for the Integration of Priority Sectors (FA) in 2004, migration and integration issues gained significance on the agenda. Primarily concerned with increasing economic growth, this framework excludes the integration of low and unskilled migrant workers; instead, ASEAN efforts to address migration and integration issues have been limited to Mutual Recognition Agreements for skilled labour and professionals. After an analysis of migration policy in the region, we highlight specific barriers to the integration of labour migrants in two priority sectors – nursing, which is highly regulated by the state, and Information, Communications and Technology (ICT), which is typically selfregulated and privately run. Despite a MRA for nursing allowing registered nurses to practice in another ASEAN country under supervision of local nurses without registering with the host country’s nursing regulatory authority, in practice, there are major barriers to the free movement of nurses within ASEAN in terms of skills recognition, licensure requirements and other protectionist measures. Although regulations governing the inflow of ICT professionals are not as stringent as those for healthcare professionals, private costs associated with job search and gaining foreign employment are higher in the ICT sector, largely due to limited information on international mobility within the industry. Three sets of barriers to greater integration are discussed. First, the economic and political diversity within ASEAN makes integration more problematic than in the European Union. Second, the primary concern with value-adding economic growth means that regional agreements are focused on skilled and professional labour migration only. Third, the “ASEAN way” of doing things – via a strong emphasis on consensus and non-interference with domestic policies – often means that the FA provision for the free movement of labour is usually trumped by domestic policies that do not reflect the same desire for labour integration

    Hypofractionated radiotherapy for prostate cancer

    Get PDF
    In the last few years, hypofractionated external beam radiotherapy has gained increasing popularity for prostate cancer treatment, since sufficient evidence exists that prostate cancer has a low alpha/beta ratio, lower than the one of the surrounding organs at risk and thus there is a potential therapeutic benefit of using larger fractionated single doses. Apart from the therapeutic rationale there are advantages such as saving treatment time and medical resources and thereby improving patient's convenience. While older trials showed unsatisfactory results in both standard and hypofractionated arm due to insufficient radiation doses and non-standard contouring of target volumes, contemporary randomized studies have reported on encouraging results of tumor control mostly without an increase of relevant side effects, especially late toxicity. Aim of this review is to give a detailed analysis of relevant, recently published clinical trials with special focus on rationale for hypofractionation and different therapy settings

    Selective area epitaxy of ultra-high density InGaN quantum dots by diblock copolymer lithography

    Get PDF
    Highly uniform InGaN-based quantum dots (QDs) grown on a nanopatterned dielectric layer defined by self-assembled diblock copolymer were performed by metal-organic chemical vapor deposition. The cylindrical-shaped nanopatterns were created on SiNx layers deposited on a GaN template, which provided the nanopatterning for the epitaxy of ultra-high density QD with uniform size and distribution. Scanning electron microscopy and atomic force microscopy measurements were conducted to investigate the QDs morphology. The InGaN/GaN QDs with density up to 8 × 1010 cm-2 are realized, which represents ultra-high dot density for highly uniform and well-controlled, nitride-based QDs, with QD diameter of approximately 22-25 nm. The photoluminescence (PL) studies indicated the importance of NH3 annealing and GaN spacer layer growth for improving the PL intensity of the SiNx-treated GaN surface, to achieve high optical-quality QDs applicable for photonics devices

    Stereotactic body radiotherapy for organ-confined prostate cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Improved understanding of prostate cancer radiobiology combined with advances in delivery of radiation to the moving prostate offer the potential to reduce treatment-related morbidity and maintain quality of life (QOL) following prostate cancer treatment. We present preliminary results following stereotactic body radiotherapy (SBRT) treatment for organ-confined prostate cancer.</p> <p>Methods</p> <p>SBRT was performed on 304 patients with clinically localized prostate cancer: 50 received 5 fractions of 7 Gy (total dose 35 Gy) and 254 received 5 fractions of 7.25 Gy (total dose 36.25 Gy). Acute and late toxicity was assessed using the Radiation Therapy Oncology Group scale. The Expanded Prostate Cancer Index Composite questionnaire was used to assess QOL. Prostate-specific antigen response was monitored.</p> <p>Results</p> <p>At a median 30-month (26 - 37 month, range) follow-up there were no biochemical failures for the 35-Gy dose level. Acute Grade II urinary and rectal toxicities occurred in 4% of patients with no higher Grade acute toxicities. One Grade II late urinary toxicity occurred with no other Grade II or higher late toxicities. At a median 17-month (8 - 27 month, range) follow-up the 36.25 Gy dose level had 2 low- and 2 high-risk patients fail biochemically (biopsy showed 2 low- and 1 high-risk patients were disease-free in the gland). Acute Grade II urinary and rectal toxicities occurred in 4.7% (12/253) and 3.6% (9/253) of patients, respectively. For those patients with a minimum of 12 months follow-up, 5.8% (12/206) had late Grade II urinary toxicity and 2.9% (6/206) had late Grade II rectal toxicities. One late Grade III urinary toxicity occurred; no Grade IV toxicities occurred. For both dose levels at 17 months, bowel and urinary QOL returned to baseline values; sexual QOL decreased by 10%.</p> <p>Conclusions</p> <p>The low toxicity and maintained QOL are highly encouraging. Additional follow-up is needed to determine long-term biochemical control and maintenance of low toxicity and QOL.</p

    A modified Inflammatory Bowel Disease questionnaire and the Vaizey Incontinence questionnaire are simple ways to identify patients with significant gastrointestinal symptoms after pelvic radiotherapy

    Get PDF
    After radiotherapy for pelvic cancer, chronic gastrointestinal problems may affect quality of life (QOL) in 6–78% of patients. This variation may be due to true differences in outcome in different diseases, and may also represent the inadequacy of the scales used to measure radiotherapy-induced gastrointestinal side effects. The aim of this study was to assess whether outcome measures used for nonmalignant gastrointestinal disease are useful to detect gastrointestinal morbidity after radiotherapy. Results obtained from a Vaizey Incontinence questionnaire and a modified Inflammatory Bowel Disease questionnaire (IBDQ) – both patient completed – were compared to those from a staff administered Late Effects on Normal Tissue (LENT) – Subjective, Objective, Management and Analytic (SOMA) questionnaire in patients who had completed radiotherapy for a pelvic tumour at least 3 months previously. In all, 142 consecutive patients were recruited, 72 male and 70 female, median age 66 years (range 26–90 years), a median of 27 (range 3–258) months after radiotherapy. In total, 62 had been treated for a gynaecological, 58, a urological and 22, a gastrointestinal tract tumour. Of these, 21 had undergone previous gastrointestinal surgery and seven suffered chronic gastrointestinal disorders preceding their diagnosis of cancer. The Vaizey questionnaire suggested that 27% patients were incontinent for solid stools, 35% for liquid stools and 37% could not defer defaecation for 15 min. The IBDQ suggested that 89% had developed a chronic change in bowel habit and this change significantly affected 49% patients: 44% had more frequent or looser bowel movements, 30% were troubled by abdominal pain, 30% were troubled by bloating, 28% complained of tenesmus, 27% were troubled by their accidental soiling and 20% had rectal bleeding. At least 34% suffered emotional distress and 22% impairment of social function because of their bowels. The small intestine/colon SOMA median score was 0.1538 (range 0–1) and the rectal SOMA median score was 0.1428 (range 0–1). Pearson's correlations for the IBDQ score and small intestine/colon SOMA score was −0.630 (P<0.001), IBDQ and rectum SOMA −0.616 (P<0.001), IBDQ and Vaizey scores −0.599 (P<0.001), Vaizey and small intestine/colon SOMA 0.452 (P<0.001) and Vaizey and rectum SOMA 0.760 (P<0.001). After radiotherapy for a tumour in the pelvis, half of all patients develop gastrointestinal morbidity, which affects their QOL. A modified IBDQ and Vaizey questionnaire are reliable in assessing new gastrointestinal symptoms as well as overall QOL and are much easier to use than LENT SOMA
    corecore