10 research outputs found

    Numerical Analysis of Viscosity Effect on Shear Horizontal Surface Acoustic Wave for Biosensor Application

    No full text

    Rayleigh SAW-Assisted SH-SAW Immunosensor on X-Cut 148-Y LiTaO 3

    No full text

    STW Gas Sensors using Microplasma-Polymerized Films

    No full text

    A Novel Rapid Test to Detect Anti-SARS-CoV-2 N Protein IgG Based on Shear Horizontal Surface Acoustic Wave (SH-SAW)

    No full text
    Since the Coronavirus disease 2019 (COVID-19) pandemic outbreak, many methods have been used to detect antigens or antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), including viral culture, nucleic acid test, and immunoassay. The shear-horizontal surface acoustic wave (SH-SAW) biosensor is a novel pathogen detection platform with the advantages of high sensitivity and short detection time. The objective of this study is to develop a SH-SAW biosensor to detect the anti-SARS-CoV-2 nucleocapsid antibody. The rabbit sera collected from rabbits on different days after SARS-CoV-2 N protein injection were evaluated by SH-SAW biosensor and enzyme-linked immunosorbent assay (ELISA). The results showed that the SH-SAW biosensor achieved a high correlation coefficient (R = 0.9997) with different concentrations (34.375–1100 ng/mL) of the “spike-in” anti-N protein antibodies. Compared to ELISA, the SH-SAW biosensor has better sensitivity and can detect anti-N protein IgG signals earlier than ELISA on day 6 (p < 0.05). Overall, in this study, we demonstrated that the SH-SAW biosensor is a promising platform for rapid in vitro diagnostic (IVD) testing, especially for antigen or antibody testing

    Towards an ultra-rapid smartphone- connected test for infectious diseases

    Get PDF
    The development is reported of an ultra-rapid, point-of-care diagnostic device which harnesses surface acoustic wave (SAW) biochips, to detect HIV in a finger prick of blood within 10 seconds (sample-in-result-out). The disposable quartz biochip, based on microelectronic components found in every consumer smartphone, is extremely fast because no complex labelling, amplification or wash steps are needed. A pocket-sized control box reads out the SAW signal and displays results electronically. High analytical sensitivity and specificity are found with model and real patient blood samples. The findings presented here open up the potential of consumer electronics to cut lengthy test waiting times, giving patients on the spot access to potentially life-saving treatment and supporting more timely public health interventions to prevent disease transmission

    A Prototype Antibody-based Biosensor for Measurement of Salivary MMP-8 in Periodontitis using Surface Acoustic Wave Technology

    No full text
    Periodontitis is an economically important disease which is highly prevalent worldwide. Current diagnostic approaches are time-consuming and require interpretation of multiple aspects of clinical and radiographic assessment. Chair-side monitoring of inflammatory mediators of periodontitis could provide immediate information about disease activity, which can inform patient management. We aimed to develop a novel prototype biosensor to measure salivary matrix metalloproteinase-8 (MMP-8) using specific antibodies and surface acoustic wave (SAW) technology. The analytical performance of the prototype biosensor was compared to standard enzyme-linked immunosorbent assay (ELISA) using unstimulated saliva samples obtained from patients with periodontitis before and after non-surgical treatment (N = 58), patients with gingivitis (N = 54) and periodontally healthy volunteers (N = 65). Receiver operator characteristic (ROC) analysis for distinguishing periodontitis from health revealed an almost identical performance between the sensor and ELISA assays (area under curve values (AUC): ELISA 0.93; SAW 0.89). Furthermore, both analytical approaches yielded readouts which distinguished between heath, gingivitis and periodontitis, correlated identically with clinical measures of periodontal disease and recorded similar post-treatment decreases in salivary MMP-8 in periodontitis. The assay time for our prototype device is 20 minutes. The prototype SAW biosensor is a novel and rapid method of monitoring periodontitis which delivers similar analytical performance to conventional laboratory assays
    corecore