267 research outputs found
Therapeutic Antibodies Targeting CSF1 Impede Macrophage Recruitment in a Xenograft Model of Tenosynovial Giant Cell Tumor
Tenosynovial giant cell tumor is a neoplastic disease of joints that can cause severe morbidity. Recurrences are common following local therapy, and no effective medical therapy currently exists. Recent work has demonstrated that all cases overexpress macrophage colony-stimulating factor (CSF1), usually as a consequence of an activating gene translocation, resulting in an influx of macrophages that form the bulk of the tumor. New anti-CSF1 drugs have been developed; however there are no preclinical models suitable for evaluation of drug benefits in this disease. In this paper, we describe a novel renal subcapsular xenograft model of tenosynovial giant cell tumor. Using this model, we demonstrate that an anti-CSF1 monoclonal antibody significantly inhibits host macrophage infiltration into this tumor. The results from this model support clinical trials of equivalent humanized agents and anti-CSF1R small molecule drugs in cases of tenosynovial giant cell tumor refractory to conventional local therapy
Dynamic radiography using a carbon-nanotube-based field-emission x-ray source
We report a dynamic radiography system with a carbon nanotube based field-emission microfocus x-ray source. The system can readily generate x-ray radiation with continuous variation of temporal resolution as short as nanoseconds. Its potential applications for dynamic x-ray imaging are demonstrated. The performance characteristics of this compact and versatile system are promising for noninvasive imaging in biomedical research and industrial inspection
Stationary scanning x-ray source based on carbon nanotube field emitters
We report a field emission x-ray source that can generate a scanning x-ray beam to image an object from multiple projection angles without mechanical motion. The key component of the device is a gated carbon nanotube field emission cathode with an array of electron emitting pixels that are individually addressable via a metal-oxide-semiconductor field effect transistor-based electronic circuit. The characteristics of this x-ray source are measured and its imaging capability is demonstrated. The device can potentially lead to a fast data acquisition rate for laminography and tomosynthesis with a simplified experimental setup
A nanotube-based field emission x-ray source for microcomputed tomography
Microcomputed tomography (micro-CT) is a noninvasive imaging tool commonly used to probe the internal structures of small animals for biomedical research and for the inspection of microelectronics. Here we report the development of a micro-CT scanner with a carbon nanotube- (CNT-) based microfocus x-ray source. The performance of the CNT x-ray source and the imaging capability of the micro-CT scanner were characterized
Partial Wave Analysis of
BES data on are presented. The
contribution peaks strongly near threshold. It is fitted with a
broad resonance with mass MeV, width MeV. A broad resonance peaking at 2020 MeV is also required
with width MeV. There is further evidence for a component
peaking at 2.55 GeV. The non- contribution is close to phase
space; it peaks at 2.6 GeV and is very different from .Comment: 15 pages, 6 figures, 1 table, Submitted to PL
BESII Detector Simulation
A Monte Carlo program based on Geant3 has been developed for BESII detector
simulation. The organization of the program is outlined, and the digitization
procedure for simulating the response of various sub-detectors is described.
Comparisons with data show that the performance of the program is generally
satisfactory.Comment: 17 pages, 14 figures, uses elsart.cls, to be submitted to NIM
PROFIL WISATAWAN MUSEUM RADYA PUSTAKA SURAKARTA
Anggit Margaret, C9407031 2011. Profil Wisatawan Museum
Radya Pustaka Surakarta. Program Studi Diploma III Usaha Perjalanan
Wisata Fakultas Sastra Dan Seni Rupa Universitas Sebelas Maret Surakarta.
Penelitian tugas akhir ini mengkaji tentang Profil Wisatawan di
Museum Radya Pustaka Surakarta. Tujuan dari penelitian ini adalah untuk
mengetahui dari daerah mana saja wisatawan yang berkunjung ke Museum
Radya Pustaka, bagaimana ciri-ciri wisatawan yang berkunjung ke Museum
Radya Pustaka serta harapan-harapan yang diinginkan wisatawan terhadap
Museum Radya Pustaka.
Penelitian dilakukan dengan metode kualitatif. Pengumpulan data
dilakukan melalui wawancara dengan narasumber wisatawan yang berkujung
di Museum Radya Pustaka Surakarta tempat penulis melakukan penelitian,
serta studi pustaka dan studi dokumen guna menambah sumber data.
Hasil penelitian menunjukkan bahwa (1) Sebagian besar wisatawan
yang datang berasal dari Semarang sebesar 32%. (2) Mayoritas wisatawan
yang berkunjung ke Museum Radya Pustaka berusia antara 17-25 tahun dan
kebanyakan dari mereka adalah pelajar atau mahasiswa dengan prosentase
52%. (3) Sebagian besar wisatawan yang datang ke Museum Radya Pustaka
adalah bertujuan untuk melakukan penelitian yaitu sebesar 34%. (4) Harapan
wisatawan yang berkunjung terhadap kelangsungan Museum Radya Pustaka
sebagian besar adalah agar ditingkatkan lagi pengelolaan dan keamanan
museum, agar kejadian hilangnya benda-benda koleksi museum tidak terulang
lagi dikemudian hari.
Kesimpulan dari hasil penelitian ini bahwa wisatawan yang berkujung
ke Museum Radya Pustaka Surakarta mayoritas berasal dari Semarang,
mayoritas berusia 17-25 tahun dan kebanyakan dari mereka adalah berprofesi
sebagai pelajar dan mahasiswa. Kebanyakan wisatawan yang datang bertujuan
untuk melakukan penelitian, serta harapan wisatawan terhadap Museum
Radya Pustaka adalah supaya lebih ditingkatkan lagi pengelolaan dan
keamanan museum
Broadband 3D isotropic negative-index metamaterial based on fishnet structure
In this paper, we numerically demonstrate a broadband 3D isotropic negative index
metamaterial (NIM) at microwave frequency ranges, which is composed of double periodic
array metallic fishnet structure (FS) etched on the six sides of a cubic dielectric
substrate. The electric and magnetic L-C resonance
circuit models are constructed to demonstrate the broadband resonance properties of the
proposed 3D metamaterial. The finite integration technology (FIT) simulation and standard
S parameters retrieval methods are used to calculate and analyze the
negative characteristics, isotropy and polarization of the 3D model. The numerical results
show that the negative index bandwidth is about 7 GHz and relative bandwidth can be up
nearly to 63%, the negative-index pass band is independent of the polarization of incident
waves and is almost the same for different oblique incident angles. Thus, the proposed
metamaterial is good candidate as a broad-band 3D isotropic NIMs
- …