14 research outputs found

    Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Get PDF
    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC.This project is at the final stages of R&D and moving to production. A large area of several 100 m 2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector.The quality control steps will include optical inspection,cleaning and baking of all materials and parts used to build the detector,leakage current tests of the GEM foils,high voltage tests,gas leak tests of the chambers and monitoring pressures time,gain calibration to know the optimal operation region of the detector,gain uniformity tests, and studying the efficiency,noise and tracking performance of the detectors in a cosmic stand using scintillator

    Upgrade of the CMS muon system with triple-GEM detectors

    Full text link

    Photochemistry of p-nitroacetophenone in 2-propanol

    No full text
    Upon irradiation in 2-propanol, p-nitroacetophenone 1 was reduced via the triplet state to p-hydroxyaminoacetophenone 5 which was further reduced to p-aminoacetophenone 2 and 4,4'-diacetylazobenzene 4. Similar irradiation of 5 also Save 2 and 4, and its oxidation by oxygen Save 4,4'-diacetylazoxybenzene 3. Photolysis of monomeric p-nitrosoacetophenone 6 afforded acetophenone and 3 that were not produced during the irradiation of 1. Possible photoreaction pathways were discussed on the basis of published mechanisms

    Nanonized black soybean enhances immune response in senescence-accelerated mice

    No full text
    Soy isoflavones may have applications in cancer prevention and anti-inflammation, therefore this study was conducted to investigate the effect of dietary supplementation with black soybean on the immune response in the senescence-accelerated-prone mice (SAMP8) and-resistant mice (SAMPR1, as controls). The mechanism of isoflavones was also investigated. Six-month-old male SAMP8 and SAMR1 mice were divided into the control groups and experimental groups supplemented with nanonized (Nano-soy) or microparticled (Micro-soy) black soybeans (n = 8/group), respectively for 12 weeks. Human peripheral blood mononuclear cells (PBMC) and murine splenocytes were stimulated with mitogens and cytokines were determined by reverse transcriptase-polymerase chain reaction and/or ELISA. The results showed that body weight, food intake, and relative weights of organs did not differ among the SAMP8 control and experimental groups. Isoflavone (daidzin and genistin) intake was higher in the Nano-soy group than the Micro-soy group. The lymphoproliferation and production of interleukin-2 (IL-2) and interferon-gamma (IFN-gamma) in the Nano-soy group had a significantly higher (P 50 mu M), daidzein only reduced IL-10 and IFN-gamma levels, whereas genistein reduced levels of the IL-2, IL-4, IL-10, IFN-gamma mRNA and protein and these results suggest that the Nano-soy supplementation improved immune response in SAMP8 mice which may be attributable to higher daidzin content in the black soybean preparation

    Upgrade of the CMS muon system with triple-GEM detectors

    No full text
    The CMS collaboration considers upgrading the muon forward region which is particularly affected by the high-luminosity conditions at the LHC. The proposal involves Gas Electron Multiplier (GEM) chambers, which are able to handle the extreme particle rates expected in this region along with a high spatial resolution. This allows to combine tracking and triggering capabilities, which will improve the CMS muon High Level Trigger, the muon identification and the track reconstruction. Intense R&D has been going on since 2009 and it has lead to the development of several GEM prototypes and associated detector electronics. These GEM prototypes have been subjected to extensive tests in the laboratory and in test beams at the CERN Super Proton Synchrotron (SPS). This contribution will review the status of the CMS upgrade project with GEMs and its impact on the CMS performance.0SCOPUS: cp.jinfo:eu-repo/semantics/publishe

    Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    No full text
    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators

    Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    No full text
    International audienceThe CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    No full text
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments

    Impact of the GE1/1 upgrade on CMS muon system performance

    No full text
    International audienceDuring the future LHC upgrade planned in 2018, the forward endcap region of the CMS muon spectrometer will be upgraded with GEM chambers. GEM technology is able to withstand the radiation environment expected in the forward region. The GE1/1 station will be included in the muon L1 trigger, allowing to keep low pT threshold even at high luminosity. Moreover, it will bring detection redundancy in the most critical part of the CMS muon system, along with benefits to muon reconstruction performance
    corecore