21 research outputs found

    Experimental Correlation of Combined Heat and Mass Transfer for NH 3 -H 2 0 falling film absorption

    Get PDF
    vection. The main conclusion from this study is that the negative concentration gradient of the surface tension is a trigger for inducement of Marangoni convection before the additive solubility, while the imbalance of the surface tension and the interfacial tension is a trigger after the solubility limit. Acknowledgment The authors thank Mr. K. Iizuka, Tokyo University of Agriculture and Technology, for his experimental assistance. The authors acknowledge that this work has been partially funded by the Japan Science and Technology Corporation (JST). References Beutler, A., Greiter, I., Wagner, A., Hohhmann, L., Schreier, S., and Alefeld, G., 1996, "Surfactants and Fluid Properties," Int. J. Refrigeration, Vol. 19, No. 5, pp. 342-346. Chavepeyer, G" Salajan, M., Platten, J. K., and Smet, P., 1995, "InterfacialTension and Surface Adsorption in j-Heptanol/Water Systems," Journal of Colloid and Interface Science, Vol. 174, Daiguji, H,, Hihara, E., and Saito, T., 1997, "Mechanism of Absorption Enhancement by Surfactant," Int. J. Heat and Mass Transfer, Vol. 40, No. 8, pp. 1743-1752. Fujita, T., 1993, "Falling Liquid Films in Absorption Machines," Int. J. Refrigeration, Vol. 16, No. 4, pp. 282-294. Hihara, E" and Saito, T., 1993 Journal of Heat Transfer TL = temperature of the fluid far away from the plate t' = time t R = reference time u = velocity of the fluid UD = reference velocity at' = frequency X,, = distance of the transition point from the leading edge |3 = coefficient of volume expansion p = density e = amplitude (constant) 9 = nondimensional temperature u = nondimensional velocity i = y-i Introduction Transient laminar-free convection flow past an infinite vertical plate under different plate conditions was studied by many researchers. The first closed-form solutions for Prandtl number Pr = 1.0 in case of a step change in wall temperature with time was derived by Illingworth (1950) and for Pr # 1.0, he derived the solution in integral form. Siegel (1958) studied the unsteady freeconvection flow past a semi-infinite vertical plate under stepchange in wall temperature or surface heat flux by employing the momentum integral method. Experimental evidence for such a situation was presented by Goldstein and Eckert (1960). For a semi-infinite vertical plate, unsteady free-convection flow was studied analytically b

    Epigenetic Drugs Can Stimulate Metastasis through Enhanced Expression of the Pro-Metastatic Ezrin Gene

    Get PDF
    Ezrin has been reported to be upregulated in many tumors and to participate in metastatic progression. No study has addressed epigenetic modification in the regulation of Ezrin gene expression, the importance of which is unknown. Here, we report that highly metastatic rhabdomyosarcoma (RMS) cells with high levels of Ezrin have elevated acetyl-H3-K9 and tri-methyl-H3-K4 as well as reduced DNA methylation at the Ezrin gene promoter. Conversely, poorly metastatic RMS cells with low levels of Ezrin have reduced acetyl-H3-K9 and elevated methylation. Thus epigenetic covalent modifications to histones within nucleosomes of the Ezrin gene promoter are linked to Ezrin expression, which in fact can be regulated by epigenetic mechanisms. Notably, treatment with histone deacetylase (HDAC) inhibitors or DNA demethylating agents could restore Ezrin expression and stimulate the metastatic potential of poorly metastatic RMS cells characterized by low Ezrin levels. However, the ability of epigenetic drugs to stimulate metastasis in RMS cells was inhibited by expression of an Ezrin-specific shRNA. Our data demonstrate the potential risk associated with clinical application of broadly acting covalent epigenetic modifiers, and highlight the value of combination therapies that include agents specifically targeting potent pro-metastatic genes

    A novel approach to determine optimum switching frequency of a conventional adsorption chiller

    No full text
    Abstract This article investigates the effect of design parameters on the switching frequency of a conventional adsorption chiller with silica gel as adsorbent and water as adsorbate. It is well known that as the cycle time lengthens, the coefficient of performance (COP) rises but the cooling capacity lowers. Optimum cycle time is dependendent on the requirements of COP and cooling capacity. A novel simulation technique that introduces a profit function is employed to determine the optimum switching frequency of an adsorption refrigeration system. The results show that optimum switching frequency is very sensitive to the heat exchanger's design parameters. The design parameters are characterized by the number of transfer unit, NTU, the Biot number of adsorbent bed, Bi, the aspect ratio, AR, the ratio of the heat exchanger thickness to the radius of the fluid channel Hr, the fluid alpha number, a f-a and the inert material alpha number, a m-a . The optimum switching frequency increases with the increase of NTU, Hr and with the decrease of Bi, AR, a m-a and a f-a

    Study on a dual-mode, multi-stage, multi-bed regenerative adsorption chiller

    No full text
    10.1016/j.renene.2005.10.003Renewable Energy31132076-209
    corecore