869 research outputs found

    Research on Excessive Labor of Couriers in Beijing

    Get PDF
    With the vigorous development of e-commerce, China’s express delivery industry ushered in the opportunity of rapid development, courier industry employment increased year by year. At the same time, the excessive labor of couriers has also aroused widespread concern in the society. This paper makes an empirical study on the over labor of expressing employees in Beijing, based on a questionnaire survey. This paper analyzes the current situation of excessive labor of express employees in Beijing. This paper probes into the deep cause of courier overwork. And put forward relevant policy recommendations accordingly

    Exploring Book-Tax Differences, Analyst Coverage, and Forecast Optimism: An Empirical Study

    Get PDF
    This research explores the relationship between book-tax differences (BTD) and the coverage of financial analysts, as well as how these two factors relate to optimistic forecasts. By evaluating how BTD affects analyst coverage, this research expands on earlier studies and finds a negative link. Additionally, it demonstrates that greater BTD indicates a higher probability of earnings manipulation, leading analysts to have a more pessimistic view of their predictions for such organizations. This research contributes to a better understanding of financial markets by shedding light on analyst behavior, financial reporting, and the complex dynamics underlying BTD in determining analyst estimates

    Simplified Seismic Design for Mid-Rise Buildings with Vertical Combination of Framing Systems

    Get PDF
    The mid-rise building with vertical combination of framing systems consists of a structural system in which the seismic-force-resisting-system (SFRS) of the upper structure is commonly a lightweight structural system such as cold-formed steel (CFS) frame or wood frame, while the SFRS associated with the lower one adopts a traditional structural system, such as reinforced concrete (RC) or structural steel frame. In current practice, the presence of: (a) vertical irregularities on mass and stiffness, and (b) damping difference between lower and upper structures creates challenges for the seismic design of such buildings. Presented in this thesis is research with aiming to solve the challenges arising from the foregoing two aspects in relatively simple and practical ways. Because of the mass irregularity in the vertical direction, the stiffness arrangement for the lower and upper structures in the combined framing system is quite different from that of the “regular” building. A simplified approach is proposed for the determination of storey-stiffness arrangements of such buildings based on the pre-determined mass distribution and specified storey drift limit. In addition, by considering both the mass and stiffness irregularities, two manually-based simplified methods, i.e., modified equivalent lateral force procedure (ELF) and two-stage analysis procedures, are proposed to evaluate seismic loads of the combined framing systems. The simplified approaches to determine the required storey-stiffness arrangements and compute seismic loads are developed based on the USA standard American Society of Civil Engineers 7 (ASCE 7) (ASCE, 2010) at first. Then, by considering the difference in seismic design provisions between ASCE 7 and the Canadian code National Building Code of Canada 2010 (NBCC 2010) (NBCC, 2010), several modifications are made on the simplified approaches based on ASCE 7 for their Canadian application. In the proposed approach to evaluate the storey-stiffness arrangements, the effects of the interaction between the lower and upper structures in terms of mass and stiffness on the seismic load are investigated. The feasible stiffness arrangements can be obtained based on the required relationship between the stiffness of the lower structure and that of the upper one determined by the proposed approach. Two examples are presented to demonstrate the efficiency of the proposed approach. The result obtained from the proposed approach is justified by the code-specified modal response spectrum analysis. The two examples demonstrate that the relative seismic weight between the lower and upper structures has a significant influence on the required stiffnesses of the lower and upper structures. In general, when the number of the storey and total seismic weight associated with the lower structure are much greater than those of the upper one, the required stiffness of the upper structure will be greatly affected by the interaction between lower and upper structures in terms of mass and stiffness. On the other hand, if the number of the storey and total seismic weight associated with the lower structure are much smaller than those of the upper one, such interaction has less effect on the required stiffness of the upper structure. In such case, the required stiffness of the upper structure is based primarily on the characteristics of the upper structure. The modified ELF procedure is applied to the combined framing systems in which there is only one-storey upper structure. Both the applicable requirements and seismic load distributions associated with the modified ELF procedure are proposed. If the storey-stiffness ratio between lower and upper structures is less than a specific value designated as rkb1, the lower structure is dominated primarily by the first mode and the traditional ELF procedure can be used to approximate the seismic load of the lower structure. However, the seismic load of the one-storey upper structure may still be underestimated as the behaviour of the upper structure may be dominated by higher vibration modes of the entire structure. Consequently, the shear force of the one-storey upper structure cannot be estimated based on the traditional ELF procedure. Equations for evaluating the shear force of the one-storey upper structure are presented in the modified ELF procedure. The two-stage analysis procedure prescribed in ASCE 7 (ASCE, 2006; 2010) ignores the interaction between lower and upper structures in terms of mass and stiffness and permits the lower and upper structure to be analyzed by the conventional ELF procedure, separately. New applicable requirements and seismic load distributions associated with the two-stage analysis procedures are proposed. The proposed procedure is compared with that prescribed in ASCE 7. It is found the stiffness requirement of ASCE 7 two-stage analysis procedure may be inappropriate, which may result in the underestimation of the base shear force of the upper structure in certain cases. Furthermore, the shear force for the top storey of the upper structure may also be considerably underestimated by the ASCE 7 two-stage analysis procedure. Therefore, an additional top shear force is to be applied to the top of upper structure. Equations to compute the additional top shear force are also provided. The accuracy of the proposed two-stage analysis procedure, either the one based on both ASCE 7 or the one based on NBCC 2010, is greatly improved compared to that prescribed in ASCE 7 (ASCE, 2006; 2010). Finally, damping difference between lower and upper structures in the combined framing system is investigated. By assuming the combined framing systems are classically damped, i.e., the damping matrix of the combined framing systems is orthogonal to the un-damped mode shape, an analytical method to approximate the equivalent modal damping ratio for the case where lower and upper structures have different damping ratios is proposed. However, as the combined framing system in fact is non-classically damped, if the lower and upper structures have different damping ratios, the proposed approximation of the equivalent modal damping ratio may lead to significant errors on seismic load in certain cases. Therefore, errors on seismic loads resulted from the classical damping approximation, which determine whether the proposed equivalent modal damping ratio is acceptable or not, are investigated. It is found large errors of seismic response associated with the proposed equivalent modal damping ratio usually occur when the dominating modes of the structures have closely spaced natural frequencies. However, for most combined framing systems in practice, the dominating modes have well separated natural frequencies and the proposed equivalent modal damping ratio is applicable to evaluate the seismic response of the combined framing systems. In addition, a new index of damping non-proportionality is suggested in this study to quantify the extent of non-proportional damping

    Mesoscale modelling in China: Risø DTU numerical wind atlas calculation for NE China (Dongbei)

    Get PDF

    Cluster Contrast for Unsupervised Person Re-Identification

    Full text link
    State-of-the-art unsupervised re-ID methods train the neural networks using a memory-based non-parametric softmax loss. Instance feature vectors stored in memory are assigned pseudo-labels by clustering and updated at instance level. However, the varying cluster sizes leads to inconsistency in the updating progress of each cluster. To solve this problem, we present Cluster Contrast which stores feature vectors and computes contrast loss at the cluster level. Our approach employs a unique cluster representation to describe each cluster, resulting in a cluster-level memory dictionary. In this way, the consistency of clustering can be effectively maintained throughout the pipline and the GPU memory consumption can be significantly reduced. Thus, our method can solve the problem of cluster inconsistency and be applicable to larger data sets. In addition, we adopt different clustering algorithms to demonstrate the robustness and generalization of our framework. The application of Cluster Contrast to a standard unsupervised re-ID pipeline achieves considerable improvements of 9.9%, 8.3%, 12.1% compared to state-of-the-art purely unsupervised re-ID methods and 5.5%, 4.8%, 4.4% mAP compared to the state-of-the-art unsupervised domain adaptation re-ID methods on the Market, Duke, and MSMT17 datasets. Code is available at https://github.com/alibaba/cluster-contrast

    On the performance of an integrated communication and localization system: an analytical framework

    Full text link
    Quantifying the performance bound of an integrated localization and communication (ILAC) system and the trade-off between communication and localization performance is critical. In this letter, we consider an ILAC system that can perform communication and localization via time-domain or frequency-domain resource allocation. We develop an analytical framework to derive the closed-form expression of the capacity loss versus localization Cramer-Rao lower bound (CRB) loss via time-domain and frequency-domain resource allocation. Simulation results validate the analytical model and demonstrate that frequency-domain resource allocation is preferable in scenarios with a smaller number of antennas at the next generation nodeB (gNB) and a larger distance between user equipment (UE) and gNB, while time-domain resource allocation is preferable in scenarios with a larger number of antennas and smaller distance between UE and the gNB.Comment: 5 pages, 3 figure
    • …
    corecore