97 research outputs found
Theory of phase segregation in DNA assemblies containing two different base pair sequence types
Spontaneous pairing of homologous DNA sequences – a challenging subject in molecular biophysics, often referred to as ‘homology recognition’ – ha s been observed in vitro for several DNA system s a . One of th e se experiments involved liquid crystalline quasi - columnar phases formed by a mixture of two kinds of oligo mer of double stranded DNA . Both oligomer types were of the same length and identical stoichiometric base - pair composition , but the base - pairs followed a different order . Phase segregation of the two DNA types was observed in the experiments , wit h the formation of boundaries between domai ns rich in molecules of one type (order) of base pair sequence . We formulate here a modified ‘ X - Y model ’ for phase segregation in such assemblies , obtain approximate solutions of the model , compare analytical results to Monte Carlo simulations, and rationalize past experimental observations . This study, furthermore , reveals the factors that affect the degree of segregat ion . Such information c ould be used in planning new versions of similar segregation experiments , needed for deepen i ng our understanding of forces that might be involved , e.g., in gene - gene recognition
Investigation of the applicability of using the triple redundant hydrogen sensor for methane sensing
Application specifications for the methane sensor were assembled and design guidelines, development goals and evaluation criteria were formulated. This was done to provide a framework to evaluate sensor performance and any design adjustments to the preprototype sensor that could be required to provide methane sensitivity. Good response to hydrogen was experimentally established for four hydrogen sensor elements to be later evaluated for methane response. Prior results were assembled and analyzed for other prototype hydrogen sensor performance parameters to form a comparison base. The four sensor elements previously shown to have good hydrogen response were experimentally evaluated for methane response in 2.5% methane-in-air. No response was obtained for any of the elements, despite the high methane concentration used (50% of the Lower Flammability Limit). It was concluded that the preprototype sensing elements were insensitive to methane and were hydrogen specific. Alternative sensor operating conditions and hardware design changes were considered to provide methane sensitivity to the preprototype sensor, including a variety of different methane sensing techniques. Minor changes to the existing sensor elements, sensor geometry and operating conditions will not make the preprototype hydrogen sensor respond to methane. New sensor elements that will provide methane and hydrogen sensitivity require replacement of the existing thermistor type elements. Some hydrogen sensing characteristics of the modified sensor will be compromised (larger in situ calibration gas volume and H2 nonspecificity). The preprototype hydrogen sensor should be retained for hydrogen monitoring and a separate methane sensor should be developed
Aircrew oxygen system
Closed-loop rebreather system which includes pilot provides oxygen for use in aircraft by safe, reliable method of low weight and size and reduces expense of ground equipment. Water electrolysis generated oxygen is fed into rebreather loop which allows nitrogen elimination and water and carbon dioxide removal
Iodine generator for reclaimed water purification
The system disclosed is for controlling the iodine level in a water supply in a spacecraft. It includes an iodine accumulator which stores crystalline iodine, an electrochemical valve to control the input of iodine to the drinking water and an iodine dispenser. A pump dispenses fluid through the iodine dispenser and an iodine sensor to a potable water tank storage. The iodine sensor electronically detects the iodine level in the water, and through electronic means, produces a correction current control. The correction current control operates the electro-chemical iodine valve to release iodine from the iodine accumulator into the iodine dispenser
Fractional capacity electrolyzer development for CO2 and H2O electrolysis
The electrolyzer module was designed to produce 0.24 kg/d (0.53 lb/d) of breathable oxygen from the electrolysis of metabolic carbon dioxide and water vapor. The fractional capacity electrolyzer module is constructed from three electrochemical tube cells and contains only three critical seals. The module design illustrated an 84 percent reduction in the total number of seals for a one person capacity oxygen generating system based on the solid electrolyte carbon dioxide and water vapor electrolysis concept. The electrolyzer module was successfully endurance tested for 71 days
Iodine generator for disinfecting reclaimed water
System dispenses iodine into water tank automatically in quantities varying from 0.5 to 20 ppm. It stores 180-day supply of iodine crystals, sufficient to support six people consuming water at rate of 4.5 to 13.6 kg per person per day
One-man, self-contained CO2 concentrating system
A program to design, fabricate, and test a 1-man, self-contained, electrochemical CO2 concentrating system is described. The system was designed with electronic controls and instrumentation to regulate performance, to analyze and display performance trends, and to detect and isolate faults. Ground support accessories were included to provide power, fluids, and a Parametric Data Display allowing real time indication of operating status in engineering units
Advanced water iodinating system
Potable water stores aboard manned spacecraft must remain sterile. Suitable sterilization techniques are needed to prevent microbial growth. The development of an advanced water iodinating system for possible application to the shuttle orbiter and other advanced spacecraft, is considered. The AWIS provides a means of automatically dispensing iodine and controlling iodination levels in potable water stores. In a recirculation mode test, simulating application of the AWIS to a water management system of a long term six man capacity space mission, noniodinated feed water flowing at 32.2 cu cm min was iodinated to 5 + or - ppm concentrations after it was mixed with previously iodinated water recirculating through a potable water storage tank. Also, the AWIS was used to successfully demonstrate its capability to maintain potable water at a desired I2 concentration level while circulating through the water storage tank, but without the addition of noniodinated water
Preprototype vapor compression distillation subsystem
A three-person capacity preprototype vapor compression distillation subsystem for recovering potable water from wastewater aboard spacecraft was designed, assembled, and tested. The major components of the subsystem are: (1) a distillation unit which includes a compressor, centrifuge, central shaft, and outer shell; (2) a purge pump; (3) a liquids pump; (4) a post-treat cartridge; (5) a recycle/filter tank; (6) an evaporator high liquid level sensor; and (7) the product water conductivity monitor. A computer based control monitor instrumentation carries out operating mode change sequences, monitors and displays subsystem parameters, maintains intramode controls, and stores and displays fault detection information. The mechanical hardware occupies 0.467 m3, requires 171 W of electrical power, and has a dry weight of 143 kg. The subsystem recovers potable water at a rate of 1.59 kg/hr, which is equivalent to a duty cycle of approximately 30% for a crew of three. The product water has no foul taste or odor. Continued development of the subsystem is recommended for reclaiming water for human consumption as well as for flash evaporator heat rejection, urinal flushing, washing, and other on-board water requirements
Prototype Bosch CO2 reduction subsystem for the RLSE experiment
Requirements for the Bosch carbon dioxide reduction subsystem were established in a study of regenerative life support evaluation experiments. A detailed design is presented including a schematic, components list and characteristics, requirements summaries, and complete definition of life systems' advanced control/monitor instrumentation applied to the Bosch subsystem. Design information needed to proceed with the final design and fabrication of a preprototype system is presented
- …