    New local field quantity describing the high gradient limit of accelerating structures

    Get PDF
    A new local field quantity is presented which gives the high gradient performance limit of accelerating structures due to vacuum rf breakdown. The new field quantity, a modified Poynting vector S_{c}, is derived from a model of the breakdown trigger in which field emission currents from potential breakdown sites cause local pulsed heating. The field quantity S_{c} takes into account both active and reactive power flow on the structure surface. This new quantity has been evaluated for many X-band and 30 GHz rf tests, both traveling wave and standing wave, and the value of S_{c} achieved in the experiments agrees well with analytical estimates

    High Power RF Induced Thermal Fatigue in the High Gradient CLIC Accelerating Structures

    Get PDF
    The need for high accelerating gradients for the CLIC (Compact Linear Collider) imposes considerable constraints on the materials of the accelerating structures. The surfaces exposed to high pulsed RF (Radio Frequency) currents are subjected to cyclic thermal stresses possibly resulting in surface break up by fatigue. Various high strength alloys from the group of high conductivity copper alloys have been selected and have been tested in different states, with different surface treatments and in different stress ratios. Low to medium cycle fatigue data (up to 108 cycles) of fully compressive surface thermal stresses has been collected by means of a pulsed laser surface heating apparatus. The surface damage has been characterized by SEM observations and roughness measurements. High cycle fatigue data, up to 7x1010 cycles, of varying stress ratio has been collected in high frequency bulk fatigue tests using an ultrasonic apparatus. Up-to-date results from these experiments are presented

    Status of the Fatigue Studies on the CLIC Accelerating Structures

    Get PDF
    The need for high accelerating gradients for the future multi-TeV e+e- Compact Linear Collider (CLIC) imposes considerable constraints on the materials of the accelerating structures. The surfaces exposed to high pulsed RF (Radio Frequency) currents are subject to cyclic thermal stresses which are expected to induce surface break up by fatigue. Since no fatigue data exists in the literature up to very large numbers of cycles and for the particular stress pattern present in RF cavities, a comprehensive study of copper alloys in this parameter range has been initiated. Fatigue data for selected copper alloys in different states are presente

    Advanced Experimental Techniques for RF and DC Breakdown Research

    Get PDF
    Advanced experimental techniques are being developed to analyze RF and DC breakdown events. First measurements with a specially built spectrometer have been made with a DC spark setup [1] at CERN and will soon be installed in the CLIC 30GHz accelerating structure test stand to allow comparison between DC and RF breakdown phenomena. This spectrometer is able to measure the light intensity development during a breakdown in narrow wavelength bands in the visible and near infrared range. This will give information about the important aspects of the breakdown including chemical elements, temperature, plasma parameters and possibly precursors of a breakdown

    Ultra-fast sampling of terahertz pulses from a quantum cascade laser using superconducting antenna-coupled NbN and YBCO detectors

    Get PDF
    We demonstrate the ultra-fast detection of terahertz pulses from a quantum cascade laser (QCL) using superconducting NbN and YBCO detectors. This has enabled both the intrapulse and interpulse dynamics of a THz QCL to be measured directly, including interpulse heating effects on sub-ÎĽs timescales

    Material Selection and Characterization for High Gradient RF Applications

    Get PDF
    The selection of candidate materials for the accelerating cavities of the Compact Linear Collider (CLIC) is carried out in parallel with high power RF testing. The maximum DC breakdown field of copper, copper alloys, refractory metals, aluminium and titanium have been measured with a dedicated setup. Higher maximum fields are obtained for refractory metals and for titanium, which exhibits, however, important damages after conditioning. Fatigue behaviour of copper alloys has been studied for surface and bulk by pulsed laser irradiation and ultrasonic excitation, respectively. The selected copper alloys show consistently higher fatigue resistance than copper in both experiments. In order to obtain the best local properties in the device a possible solution is a bi-metallic assembly. Junctions of molybdenum and copper-zirconium UNS C15000 alloy, achieved by HIP (Hot Isostatic Pressing) diffusion bonding or explosion bonding were evaluated for their mechanical strength. The reliability of the results obtained with both techniques should be improved. Testing in DC and radiofrequency (RF) is continued in order to select materials for a bi-metal exhibiting superior properties with respect to the combination C15000-Mo
    • …